Viscoelastic property measurement in thin tissue constructs using ultrasound

被引:38
|
作者
Liu, Dalong [2 ]
Ebbini, Emad S. [1 ]
机构
[1] Univ Minnesota, Dept Elect & Comp Engn, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Biomed Engn, Minneapolis, MN USA
基金
美国国家卫生研究院;
关键词
D O I
10.1109/TUFFC.2008.655
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We present a dual-element concave ultrasound transducer system for generating and tracking of localized tissue displacements in thin tissue constructs on rigid substrates. The system is comprised of a highly focused PZT-4 5-MHz acoustic radiation force (ARF) transducer and a confocal 25-MHz polyvinylidene fluoride imaging transducer. This allows for the generation of measurable displacements in tissue samples on rigid substrates with thickness values down to 500 mu m. Impulse-like and longer duration sine-modulated ARF pulses are possible with intermittent M-mode data acquisition for displacement tracking. The operations of the ARF and imaging transducers are strictly synchronized using an integrated system for arbitrary waveform generation and data capture with a shared timebase. This allows for virtually jitter-free pulse-echo data well suited for correlation-based speckle tracking. With this technique we could faithfully capture the entire dynamics of the tissue axial deformation at pulse-repetition frequency values up to 10 kHz. Spatio-temporal maps of tissue displacements in response to a variety of modulated ARF beams were produced in tissue-mimicking elastography phantoms on rigid substrates. The frequency response was measured for phantoms with different modulus and thickness values. The frequency response exhibited resonant behavior with the resonance frequency being inversely proportional to the sample thickness. This resonant behavior can be used in obtaining high-contrast imaging using magnitude and phase response to sinusoidally modulated ARF beams. Furthermore, a second order forced harmonic oscillator (FHO) model was shown to capture this resonant behavior. Based on the FHO model, we used the extended Kalman filter (EKF) for tracking the apparent modulus and viscosity of samples subjected to do and sinusoidally modulated ARF. The results show that the stiffness (apparent modulus) term in the FHO is largely time-invariant and can be estimated robustly using the EKF. On the other hand, the damping (apparent viscosity) is time varying. These findings were confirmed by comparing the magnitude response of the FHO (with parameters obtained using the EKF) with the measured ones for different thin tissue constructs.
引用
收藏
页码:368 / 383
页数:16
相关论文
共 50 条
  • [21] Viscoelastic characterization of biological tissue by photoacoustic measurement
    Ishihara, M. (kobako@cc.ndmc.ac.jp), 1600, Japan Society of Applied Physics (42):
  • [22] Viscoelastic characterization of biological tissue by photoacoustic measurement
    Ishihara, M
    Sato, M
    Sato, S
    Kikuchi, T
    Fujikawa, K
    Kikuchi, M
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS & EXPRESS LETTERS, 2003, 42 (5B): : L556 - L558
  • [23] Viscoelastic Properties of Tissue Mimicking Phantoms for Ultrasound Elastograpghy
    Kumar, Kishore
    Jayashankar, V.
    Kumar, V. Jagadeesh
    Andrews, M. E.
    Mishra, A. K.
    I2MTC: 2009 IEEE INSTRUMENTATION & MEASUREMENT TECHNOLOGY CONFERENCE, VOLS 1-3, 2009, : 1469 - +
  • [24] A VISCOELASTIC MODEL OF THE INTERACTION OF ULTRASOUND PULSES WITH BIOLOGICAL TISSUE
    HARAN, ME
    LEWIN, PA
    ULTRASONIC IMAGING, 1984, 6 (02) : 240 - 240
  • [25] DESIGN OF A TISSUE RESONATOR INDENTER DEVICE FOR MEASUREMENT OF SOFT TISSUE VISCOELASTIC PROPERTIES USING PARAMETRIC IDENTIFICATION
    Hariri, Alireza
    Zu, Jean W.
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCES AND COMPUTERS AND INFORMATION IN ENGINEERING CONFERENCE, VOL 3, 2010, : 89 - 97
  • [26] Choroidal thickness measurement using tissue identification with high frequency ultrasound
    Chan, R
    Coleman, D
    Rondeau, MJ
    Silverman, RH
    Lloyd, HO
    Lizzi, FL
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 : U51 - U51
  • [27] Tissue stiffness measurement using temporal variation of ultrasound speckle pattern
    Jeong, MK
    Park, JM
    Kwon, SJ
    Bae, MH
    MEDICAL IMAGING 2003: ULTRASONIC IMAGING AND SIGNAL PROCESSING, 2003, 5035 : 349 - 356
  • [28] Importance of Viscoelastic Property Measurement of a New Hydrogel for Health Care
    Roy, Niladri
    Saha, Nabanita
    Kitano, Takeshi
    Saha, Petr
    NOVEL TRENDS IN RHEOLOGY III, 2009, 1152 : 210 - 216
  • [29] COMBINING OPTICS AND ULTRASOUND TO IMAGE 3D TISSUE CONSTRUCTS
    He, D.
    Huynh, N. T.
    Ruan, H.
    Zhang, F.
    Mather, M. L.
    Parker, N. G.
    Hayes-Gill, B. R.
    Crowe, J. A.
    Rose, F. R. A. J.
    Povey, M. J. W.
    Morgan, S. P.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2011, 34 (08): : 694 - 694
  • [30] Ultrasound and Photoacoustic Imaging to Monitor Vascular Growth in Tissue Engineered Constructs
    Nam, Seung Yun
    Mallidi, Srivalleesha
    Zhang, Ge
    Suggs, Laura J.
    Emelianov, Stanislav
    OPTICS IN TISSUE ENGINEERING AND REGENERATIVE MEDICINE III, 2009, 7179