A method for determining valve coefficient and resistance coefficient for predicting gas flowrate

被引:20
作者
Long, Chunxia [2 ]
Guan, Jianyu [1 ]
机构
[1] S China Univ Technol, Sch Chem & Chem Engn, Guangzhou 510640, Guangdong, Peoples R China
[2] Guangdong Pharmaceut Univ, Sch Chem & Chem Engn, Guangzhou 510006, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Valve flow coefficient; Resistance coefficient; Fluid flow; Compressible fluid;
D O I
10.1016/j.expthermflusci.2011.04.001
中图分类号
O414.1 [热力学];
学科分类号
摘要
A method is introduced to determine the valve flow coefficient and resistance coefficient with the experiment of air discharging from a reservoir, and with the least squares method to fit the cumulative molar quantities discharged. The test valve is an angle-seat valve (Type 2632, Burkert) with different apertures. At pressure difference of about 6 bar, the choked flow occurs when the valve aperture over 60%. Both the valve coefficient and resistance coefficient model can exactly predict the flowrate for the non-choked flow, while there are larger deviations for the choked flow. The modified equation for the choked flow can improve the prediction. In the resistance coefficient model, the value of resistance coefficient and the discharged cumulative molar quantities obtained with both the compressible and incompressible assumption are very close. The compressibility of air is negligible within the experimental pressure difference of about 6 bar. The additivity of the resistance coefficient makes the model more convenient to use. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:1162 / 1168
页数:7
相关论文
共 10 条