Determination of methamphetamine enantiomer composition in human hair by non-chiral liquid chromatography-tandem mass spectrometry method

被引:17
作者
Shu, Irene [1 ]
Alexander, Amy [1 ]
Jones, Mary [1 ]
Jones, Joseph [1 ]
Negrusz, Adam [1 ]
机构
[1] US Drug Testing Labs Inc, 1700 S Mt Prospect Rd, Des Plaines, IL 60018 USA
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2016年 / 1028卷
关键词
Marfey's reagent; Non-chiral chromatography; Hair analysis; Enantiomer composition; CHIRAL SEPARATION; ORAL FLUID; CAPILLARY-ELECTROPHORESIS; FLUORESCENCE DETECTION; DECOLORANT TREATMENTS; MARFEYS REAGENT; AMPHETAMINE; PLASMA; URINE; MDMA;
D O I
10.1016/j.jchromb.2016.06.015
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Chiral separation is crucial for investigating methamphetamine positive cases. While (S)-(+)-enantiomer of methamphetamine (S-MAMP) is a schedule II controlled substance, (R)-(-)-enantiomer (R-MAMA) is an active ingredient of a few over-the-counter drugs in the United States. Among biological specimen types, hair provides greater detection window than blood, urine or oral fluid, and are therefore regarded with particular interest. Herein we describe a novel non-chiral liquid chromatography-tandem mass spectrometry (LC-MS/MS) method to directly determine methamphetamine enantiomeric composition (percentage) in hair specimens. Hair samples were washed once with acetone, powdered, incubated overnight at 53 degrees C in 0.1 M hydrochloric acid (HCI), and subjected to a solid phase extraction (SPE). The extracts were derivatized using Marfey's reagent at 53 degrees C for 60 min. The final mixture was analyzed by LC-MS/MS. Chromatographic separation was achieved using a C-18 Kinetex analytical column and 60% (v/v) aqueous methanol as mobile phase (isocratic). Triple quadrupole mass spectrometer was equipped with an electro-spray ionization (ESI) source operating in negative mode and the chromatograms were acquired using a multiple-reaction monitoring (MRM) approach. The results were expressed as ratio of R- to S-MAMP and then derived to composition percentages without requiring quantitating each enantiomer. The method was precise and accurate across 0-100% S-composition at a range of 80-18,000 pg/mg. The performance of the new method was compared with an (S)-(-)-N-trifluoroacetylprolyl chloride (S-TPC) derivatization and gas chromatography-mass spectrometry (GC MS) method on authentic methamphetamine-positive hair samples. Not only the new Marfey's reagent approach presented satisfactory correlation with the S-TPC approach, but it also exhibited significantly improved quality (e.g., S/N) of the chromatograms. In summary, our protocol employs cost effective and minimally hazardous Marfey's reagent to derivatize trace amounts of methamphetamine extracted from hair samples and a non-chiral LC-MS/MS approach to separate and identify the two enantiomers. The method allows determination of the methamphetamine enantiomeric composition without requiring quantitation of each enantiomer and is therefore well suited for further investigate previously determined methamphetamine positive cases. This method represents a viable tool for evaluation Of long-term drug exposure. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:145 / 152
页数:8
相关论文
共 39 条
[1]  
Al-Dirbashi O, 1999, BIOMED CHROMATOGR, V13, P543, DOI 10.1002/(SICI)1099-0801(199912)13:8<543::AID-BMC925>3.0.CO
[2]  
2-7
[3]  
Al-Dirbashi OY, 2000, BIOMED CHROMATOGR, V14, P293, DOI 10.1002/1099-0801(200008)14:5<293::AID-BMC2>3.0.CO
[4]  
2-K
[6]  
[Anonymous], 2001, Guidance for industry: bioanalytical method validation, P1
[7]  
[Anonymous], 2015, Fed. Regist, V80, P28054
[8]   Marfey's reagent for chiral amino acid analysis:: A review [J].
Bhushan, R ;
Brückner, H .
AMINO ACIDS, 2004, 27 (3-4) :231-247
[9]   METABOLISM OF [C-14]METHAMPHETAMINE IN MAN, GUINEA-PIG AND RAT [J].
CALDWELL, J ;
DRING, LG ;
WILLIAMS, RT .
BIOCHEMICAL JOURNAL, 1972, 129 (01) :11-&
[10]  
Cody J D, 1993, Forensic Sci Rev, V5, P109