The validity of ultrasound estimation of muscle volumes

被引:19
作者
Infantolino, Benjamin W. [1 ]
Gales, Daniel J. [1 ]
Winter, Samantha L. [1 ]
Challis, John H. [1 ]
机构
[1] Penn State Univ, Biomech Lab, University Pk, PA 16802 USA
关键词
imaging; Cavalieri method; vastus lateralis;
D O I
10.1123/jab.23.3.213
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to validate ultrasound muscle volume estimation in vivo. To examine validity, vastus lateralis ultrasound images were collected from cadavers before muscle dissection; after dissection, the volumes were determined by hydrostatic weighing. Seven thighs from cadaver specimens were scanned using a 7.5-MHz ultrasound probe (SSD- 1000, Aloka, Japan). The perimeter of the vastus lateralis was identified in the ultrasound images and manually digitized. Volumes were then estimated using the Cavalieri principle, by measuring the image areas of sets of parallel two-dimensional slices through the muscles. The muscles were then dissected from the cadavers, and muscle volume was determined via hydrostatic weighing. There was no statistically significant difference between the ultrasound estimation of muscle volume and that estimated using hydrostatic weighing (p > 0.05). The mean percentage error between the two volume estimates was 0.4 +/- 6.9. Three operators all performed four digitizations of all images from one randomly selected muscle; there was no statistical difference between operators or trials and the intraclass correlation was high (> 0.8). The results of this study indicate that ultrasound is an accurate method for estimating muscle volumes in vivo.
引用
收藏
页码:213 / 217
页数:5
相关论文
共 14 条
[1]   Measuring agreement in method comparison studies [J].
Bland, JM ;
Altman, DG .
STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) :135-160
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Determining the force-length-velocity relations of the quadriceps muscles: I. Anatomical and geometric parameters [J].
Chow, JW ;
Darling, WG ;
Ehrhardt, JC .
JOURNAL OF APPLIED BIOMECHANICS, 1999, 15 (02) :182-190
[4]  
Daintith J., 1989, PENGUIN DICT MATH
[5]  
ENGSTROM CM, 1991, J ANAT, V176, P139
[6]   Measurement of human muscle volume using ultrasonography [J].
Esformes, JI ;
Narici, MV ;
Maganaris, CN .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 87 (01) :90-92
[7]   MUSCLE-FIBER ARCHITECTURE IN THE HUMAN LOWER-LIMB [J].
FRIEDERICH, JA ;
BRAND, RA .
JOURNAL OF BIOMECHANICS, 1990, 23 (01) :91-95
[8]   Volume estimation of extensor muscles of the lower leg based on MR imaging [J].
Lund, H ;
Christensen, L ;
Savnik, A ;
Boesen, J ;
Danneskiold-Samsoe, B ;
Bliddal, H .
EUROPEAN RADIOLOGY, 2002, 12 (12) :2982-2987
[9]   Cadaver validation of skeletal muscle measurement by magnetic resonance imaging and computerized tomography [J].
Mitsiopoulos, N ;
Baumgartner, RN ;
Heymsfield, SB ;
Lyons, W ;
Gallagher, D ;
Ross, R .
JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (01) :115-122
[10]   The accuracy of volume estimates using ultrasound muscle thickness measurements in different muscle groups [J].
Miyatani, M ;
Kanehisa, H ;
Ito, M ;
Kawakami, Y ;
Fukunaga, T .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 91 (2-3) :264-272