Temperature Changes and SEM Effects of Three Different Implants-Abutment Connection during Debridement with Er:YAG Laser: An Ex Vivo Study

被引:12
作者
Matys, Jacek [1 ,2 ]
Romeo, Umberto [3 ]
Mroczka, Krzysztof [4 ]
Grzech-Lesniak, Kinga [1 ,5 ]
Dominiak, Marzena [1 ]
机构
[1] Med Univ, Dent Surg Dept, PL-50425 Wroclaw, Poland
[2] Private Dent Practice, Lipowa 18, PL-67400 Wschowa, Poland
[3] Dept Oral Sci & Maxillofacial Surg, I-00161 Rome, Italy
[4] Pedag Univ, Inst Technol, PL-30084 Krakow, Poland
[5] Virginia Commonwealth Univ, Sch Dent, Dept Periodont, Richmond, VA 23298 USA
关键词
one-piece implant; peri-implantitis; peri-mucositis; titanium; two-piece implant; ER-YAG LASER; IN-VITRO; PERI-IMPLANTITIS; SURFACE DECONTAMINATION; NONSURGICAL TREATMENT; TITANIUM IMPLANTS; DIODE-LASER; BONE; IRRADIATION; VIABILITY;
D O I
10.3390/ma12223748
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The study aimed to evaluate a temperature increase in, and damage to, titanium implants during flapless laser debridement. The study analyzed 15 implants with various implant-abutment connections: a two-piece implant (n = 4) with a screw abutment (IA-Implant-Abutment) and a one-piece implant with a ball type fixture (BTF, n = 4) or fix type fixture (FTF, n = 4). The implants were placed in porcine mandibles 2 mm over a bone crest to imitate a peri-implantitis. The implants were debrided in contact mode for 60 s with a Er:YAG laser at fluence of 9.95 J/cm(2) (G1 group: 50 mJ/30 Hz); 19.89 J/cm(2) (G2 group: 100 mJ/30 Hz); 39.79 J/cm(2) (G3 group: 200 mJ/30 Hz), or a scaler with a ceramic tip (G4 control group: 4 W/20 Hz). The temperature was measured with thermocouples at implant and abutment levels. The damage in the titanium surface (n = 3, non-irradiated implants from each type) was assessed using SEM (Scanning Electron Microscopy). The temperature increase at the implant level for the laser was higher at IA in contrast with FTF and BTF. (p < 0.05) The temperature change at the abutment level was lower for the scaler in contrast to Er:YAG laser at FTF. (p < 0.0002) Er:YAG laser didn't increase the temperature by 10 degrees C at 100 mJ/30 Hz and 50 mJ/30 Hz. Based on SEM analysis, cracks occurred on the surface of two-piece implants and were more pronounced. Cracks and the melting of the titanium surface of two-piece implants cleaned with Er:YAG laser at 100 or 200 mJ were observed. The specimens treated with the ultrasonic scaler with a plastic curette showed the remaining dark debris on the titanium surface. We recommend using Er:YAG laser at 50 mJ/30 Hz during flapless implants debridement.
引用
收藏
页数:13
相关论文
共 52 条
[1]   Managing Peri-Implant Bone Loss: Current Understanding [J].
Aljateeli, Manar ;
Fu, Jia-Hui ;
Wang, Hom-Lay .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 :e109-e118
[2]  
[Anonymous], CLIN ORAL IMPLANTS R
[3]   The Frequency of Peri-Implant Diseases: A Systematic Review and Meta-Analysis [J].
Atieh, Momen A. ;
Alsabeeha, Nabeel H. M. ;
Faggion, Clovis Mariano, Jr. ;
Duncan, Warwick J. .
JOURNAL OF PERIODONTOLOGY, 2013, 84 (11) :1586-1598
[4]   In vitro studies on the effect of cleaning methods on different implant surfaces [J].
Augthun, M ;
Tinschert, J ;
Huber, A .
JOURNAL OF PERIODONTOLOGY, 1998, 69 (08) :857-864
[5]   Surgical Treatment of Peri-Implantitis: A 17-Year Follow-Up Clinical Case Report [J].
Bassi, Fabrizio ;
Poli, Pier Paolo ;
Rancitelli, Davide ;
Signorino, Fabrizio ;
Maiorana, Carlo .
CASE REPORTS IN DENTISTRY, 2015, 2015
[6]  
BERGENDAL T, 1990, SWED DENT J, V14, P219
[7]   Surgical treatment of peri-implantitis [J].
Claffey, Noel ;
Clarke, Emily ;
Polyzois, Ioannis ;
Renvert, Stefan .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2008, 35 :316-332
[8]   Cooling Profile Following Prosthetic Preparation of 1-Piece Dental Implants [J].
Cohen, Omer ;
Gabay, Eran ;
Machtei, Eli E. .
JOURNAL OF ORAL IMPLANTOLOGY, 2010, 36 (04) :273-280
[9]   TEMPERATURE THRESHOLD LEVELS FOR HEAT-INDUCED BONE TISSUE-INJURY - A VITAL-MICROSCOPIC STUDY IN THE RABBIT [J].
ERIKSSON, AR ;
ALBREKTSSON, T .
JOURNAL OF PROSTHETIC DENTISTRY, 1983, 50 (01) :101-107
[10]   ASSESSMENT OF BONE VIABILITY AFTER HEAT TRAUMA - A HISTOLOGICAL, HISTOCHEMICAL AND VITAL MICROSCOPIC STUDY IN THE RABBIT [J].
ERIKSSON, RA ;
ALBREKTSSON, T ;
MAGNUSSON, B .
SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 1984, 18 (03) :261-268