A dosimetric uncertainty analysis for photon-emitting brachytherapy sources: Report of AAPM Task Group No. 138 and GEC-ESTRO

被引:210
作者
DeWerd, Larry A. [1 ,2 ]
Ibbott, Geoffrey S. [3 ]
Meigooni, Ali S. [4 ]
Mitch, Michael G. [5 ]
Rivard, Mark J. [6 ]
Stump, Kurt E. [7 ]
Thomadsen, Bruce R. [8 ,9 ]
Venselaar, Jack L. M. [10 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[2] Univ Wisconsin, Accredited Dosimetry Calibrat Lab, Madison, WI 53706 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[4] Comprehens Canc Ctr Nevada, Dept Radiat Oncol, Las Vegas, NV 89169 USA
[5] NIST, Ionizing Radiat Div, Gaithersburg, MD 20899 USA
[6] Tufts Univ, Sch Med, Dept Radiat Oncol, Boston, MA 02111 USA
[7] Santa Maria Radiat Oncol Ctr, Santa Maria, CA 93454 USA
[8] Univ Wisconsin, Dept Med Phys, Madison, WI 53706 USA
[9] Univ Wisconsin, Dept Human Oncol, Madison, WI 53706 USA
[10] Inst Verbeeten, Dept Med Phys & Engn, NL-5042 SB Tilburg, Netherlands
关键词
brachytherapy; dosimetry; uncertainty; standards; RADIOCHROMIC FILM DOSIMETRY; AIR-KERMA RATE; ABANDON GEOMETRY FACTORS; IN-VIVO DOSIMETRY; LOW-ENERGY; HDR BRACHYTHERAPY; THERMOLUMINESCENCE DOSIMETRY; STRENGTH STANDARDS; PROSTATE IMPLANTS; MOSFET DETECTORS;
D O I
10.1118/1.3533720
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This report addresses uncertainties pertaining to brachytherapy single-source dosimetry preceding clinical use. The International Organization for Standardization (ISO) Guide to the Expression of Uncertainty in Measurement (GUM) and the National Institute of Standards and Technology (NIST) Technical Note 1297 are taken as reference standards for uncertainty formalism. Uncertainties in using detectors to measure or utilizing Monte Carlo methods to estimate brachytherapy dose distributions are provided with discussion of the components intrinsic to the overall dosimetric assessment. Uncertainties provided are based on published observations and cited when available. The uncertainty propagation from the primary calibration standard through transfer to the clinic for air-kerma strength is covered first. Uncertainties in each of the brachytherapy dosimetry parameters of the TG-43 formalism are then explored, ending with transfer to the clinic and recommended approaches. Dosimetric uncertainties during treatment delivery are considered briefly but are not included in the detailed analysis. For low-and high-energy brachytherapy sources of low dose rate and high dose rate, a combined dosimetric uncertainty <5% (k=1) is estimated, which is consistent with prior literature estimates. Recommendations are provided for clinical medical physicists, dosimetry investigators, and source and treatment planning system manufacturers. These recommendations include the use of the GUM and NIST reports, a requirement of constancy of manufacturer source design, dosimetry investigator guidelines, provision of the lowest uncertainty for patient treatment dosimetry, and the establishment of an action level based on dosimetric uncertainty. These recommendations reflect the guidance of the American Association of Physicists in Medicine (AAPM) and the Groupe Europeen de Curietherapie-European Society for Therapeutic Radiology and Oncology (GEC-ESTRO) for their members and may also be used as guidance to manufacturers and regulatory agencies in developing good manufacturing practices for sources used in routine clinical treatments. (C) 2011 American Association of Physicists in Medicine. [DOI: 10.1118/1.3533720]
引用
收藏
页码:782 / 801
页数:20
相关论文
共 84 条
[1]   The use of a reflective scanner to study radiochromic film response [J].
Alva, H ;
Mercado-Uribe, H ;
Rodríguez-Villafuerte, M ;
Brandan, ME .
PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (16) :2925-2933
[2]  
[Anonymous], 2008, 100 ISO JCGM
[3]  
[Anonymous], CLIN DOSIMETRY MEASU
[4]  
[Anonymous], 1997, UCRL50400 LAWR LIV N
[5]   Energy dependence and dose response of Gafchromic EBT2 film over a wide range of photon, electron, and proton beam energies [J].
Arjomandy, Bijan ;
Tailor, Ramesh ;
Anand, Aman ;
Sahoo, Narayan ;
Gillin, Michael ;
Prado, Karl ;
Vicic, Milos .
MEDICAL PHYSICS, 2010, 37 (05) :1942-1947
[6]   Study of encapsulated 170Tm sources for their potential use in brachytherapy [J].
Ballester, Facundo ;
Granero, Domingo ;
Perez-Calatayud, Jose ;
Venselaar, Jack L. M. ;
Rivard, Mark J. .
MEDICAL PHYSICS, 2010, 37 (04) :1629-1637
[7]   Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons [J].
Ballester, Facundo ;
Granero, Domingo ;
Perez-Calatayud, Jose ;
Melhus, Christopher S. ;
Rivard, Mark J. .
MEDICAL PHYSICS, 2009, 36 (09) :4250-4256
[8]   Beta versus gamma dosimetry close to Ir-192 brachytherapy sources [J].
Baltas, D ;
Karaiskos, P ;
Papagiannis, P ;
Sakelliou, L ;
Loeffler, E ;
Zamboglou, N .
MEDICAL PHYSICS, 2001, 28 (09) :1875-1882
[9]   A new miniature x-ray device for interstitial radiosurgery: Dosimetry [J].
Beatty, J ;
Biggs, PJ ;
Gall, K ;
Okunieff, P ;
Pardo, FS ;
Harte, KJ ;
Dalterio, MJ ;
Sliski, AP .
MEDICAL PHYSICS, 1996, 23 (01) :53-62
[10]   The IPEM code of practice for determination of the reference air kerma rate for HDR 192Ir brachytherapy sources based on the NPL air kerma standard [J].
Bidmead, A. M. ;
Sander, T. ;
Locks, S. M. ;
Lee, C. D. ;
Aird, E. G. A. ;
Nutbrown, R. F. ;
Flynn, A. .
PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (11) :3145-3159