SETUP REPRODUCIBILITY FOR THORACIC AND UPPER GASTROINTESTINAL RADIATION THERAPY: INFLUENCE OF IMMOBILIZATION METHOD AND ON-LINE CONE-BEAM CT GUIDANCE

被引:14
作者
Li, Winnie [1 ]
Moseley, Douglas J.
Bissonnette, Jean-Pierre
Purdie, Thomas G.
Bezjak, Andrea
Jaffray, David A.
机构
[1] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
关键词
Thoracic and upper gastrointestinal radiotherapy; Cone-beam CT; Immobilization; Margins; IMAGE-GUIDED RADIOTHERAPY; FLAT-PANEL IMAGER; CELL LUNG-CANCER; COMPUTED-TOMOGRAPHY; CONFORMAL RADIOTHERAPY; PROSTATE-CANCER; ERRORS; LOCALIZATION; VERIFICATION; MARGINS;
D O I
10.1016/j.meddos.2009.09.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We report the setup reproducibility of thoracic and upper gastrointestinal (UGI) radiotherapy (RT) patients for 2 immobilization methods evaluated through cone-beam computed tomography (CBCT) image guidance, and present planning target volume (PTV) margin calculations made on the basis of these observations. Daily CBCT images from 65 patients immobilized in a chestboard (CB) or evacuated cushion (EC) were registered to the planning CT using automatic bony anatomy registration. The standardized region-of-interest for matching was focused around vertebral bodies adjacent to tumor location. Discrepancies >3 mm between the CBCT and CT datasets were corrected before initiation of RT and verified with a second CBCT to assess residual error (usually taken after 90 s of the initial CBCT). Positional data were analyzed to evaluate the magnitude and frequencies of setup errors before and after correction. The setup distributions were slightly different for the CB (797 scans) and EC (757 scans) methods, and the probability of adjustment at a 3-mm action threshold was not significantly different (p = 0.47). Setup displacements >10 mm in any direction were observed in 10% of CB fractions and 16% of EC fractions (p = 0.0008). Residual error distributions after CBCT guidance were equivalent regardless of immobilization method. Using a published formula, the PTV margins for the CB were L/R, 3.3 mm; S/I, 3.5 mm; and A/P, 4.6 mm), and for EC they were L/R, 3.7 mm; S/I, 3.3 mm; and A/P, 4.6 mm. In the absence of image guidance, the CB slightly outperformed the EC in precision. CBCT allows reduction to a single immobilization system that can be chosen for efficiency, logistics, and cost. Image guidance allows for increased geometric precision and accuracy and supports a corresponding reduction in PTV margin. 0 2010 American Association of Medical Dosimetrists.
引用
收藏
页码:287 / 296
页数:10
相关论文
共 50 条
  • [41] Prospective In Silico Evaluation of Cone-Beam Computed Tomography-Guided StereoTactic Adaptive Radiation Therapy (CT-STAR) for the Ablative Treatment of Ultracentral Thoracic Disease
    Schiff, Joshua P.
    Laugeman, Eric
    Stowe, Hayley B.
    Zhao, Xiaodong
    Hilliard, Jessica
    Hawk, Ellie
    Watkins, Jesiah
    Hatscher, Casey
    Badiyan, Shahed N.
    Samson, Pamela P.
    Hugo, Geoffrey D.
    Robinson, Clifford G.
    Price, Alex T.
    Henke, Lauren E.
    ADVANCES IN RADIATION ONCOLOGY, 2023, 8 (06)
  • [42] Comprehensive evaluations of cone-beam CT dose in image-guided radiation therapy via GPU-based Monte Carlo simulations
    Montanari, Davide
    Scolari, Enrica
    Silvestri, Chiara
    Graves, Yan Jiang
    Yan, Hao
    Cervino, Laura
    Rice, Roger
    Jiang, Steve B.
    Jia, Xun
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (05) : 1239 - 1253
  • [43] Frameless fractionated stereotactic radiation therapy of intracranial lesions: impact of cone beam CT based setup correction on dose distribution
    Haertl, Petra Maria
    Loeschel, Rainer
    Repp, Natalia
    Pohl, Fabian
    Koelbl, Oliver
    Dobler, Barbara
    RADIATION ONCOLOGY, 2013, 8
  • [44] Evaluation of a cycle-generative adversarial network-based cone-beam CT to synthetic CT conversion algorithm for adaptive radiation therapy
    Eckl, Miriam
    Hoppen, Lea
    Sarria, Gustavo R.
    Boda-Heggemann, Judit
    Simeonova-Chergou, Anna
    Steil, Volker
    Giordano, Frank A.
    Fleckenstein, Jens
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 308 - 316
  • [45] On-Line Use of Three-Dimensional Marker Trajectory Estimation From Cone-Beam Computed Tomography Projections for Precise Setup in Radiotherapy for Targets With Respiratory Motion
    Worm, Esben S.
    Hoyer, Morten
    Fledelius, Walther
    Nielsen, Jens E.
    Larsen, Lars P.
    Poulsen, Per R.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 83 (01): : E145 - E151
  • [46] Radiation doses and accuracy of navigated pedicle screw placement in cervical and thoracic spine surgery: a comparison of sliding gantry CT and mobile cone-beam CT in a homogeneous cohort
    Baumgart, Lea
    Ille, Sebastian
    Kirschke, Jan S.
    Meyer, Bernhard
    Krieg, Sandro M.
    JOURNAL OF NEUROSURGERY-SPINE, 2023, 39 (03) : 363 - 369
  • [47] Set-up errors in head and neck cancer patients treated with intensity modulated radiation therapy: Quantitative comparison between three-dimensional cone-beam CT and two-dimensional kilovoltage images
    Ciardo, Delia
    Alterio, Daniela
    Jereczek-Fossa, Barbara Alicja
    Riboldi, Marco
    Zerini, Dario
    Santoro, Luigi
    Preve, Eleonora
    Rondi, Elena
    Comi, Stefania
    Serafini, Flavia
    Laudati, Antonio
    Ansarin, Mohssen
    Preda, Lorenzo
    Baroni, Guido
    Orecchia, Roberto
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 1015 - 1021
  • [48] Image quality in thoracic 4D cone-beam CT: A sensitivity analysis of respiratory signal, binning method, reconstruction algorithm, and projection angular spacing
    Shieh, Chun-Chien
    Kipritidis, John
    O'Brien, Ricky T.
    Kuncic, Zdenka
    Keall, Paul J.
    MEDICAL PHYSICS, 2014, 41 (04)
  • [49] A transformer-based dual-domain network for reconstructing FOV extended cone-beam CT images from truncated sinograms in radiation therapy
    Gao, Liugang
    Xie, Kai
    Sun, Jiawei
    Lin, Tao
    Sui, Jianfeng
    Yang, Guanyu
    Ni, Xinye
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2023, 241
  • [50] Towards the clinical implementation of iterative low-dose cone-beam CT reconstruction in image-guided radiation therapy: Cone/ring artifact correction and multiple GPU implementation
    Yan, Hao
    Wang, Xiaoyu
    Shi, Feng
    Bai, Ti
    Folkerts, Michael
    Cervino, Laura
    Jiang, Steve B.
    Jia, Xun
    MEDICAL PHYSICS, 2014, 41 (11)