SETUP REPRODUCIBILITY FOR THORACIC AND UPPER GASTROINTESTINAL RADIATION THERAPY: INFLUENCE OF IMMOBILIZATION METHOD AND ON-LINE CONE-BEAM CT GUIDANCE

被引:14
|
作者
Li, Winnie [1 ]
Moseley, Douglas J.
Bissonnette, Jean-Pierre
Purdie, Thomas G.
Bezjak, Andrea
Jaffray, David A.
机构
[1] Princess Margaret Hosp, Radiat Med Program, Toronto, ON M5G 2M9, Canada
关键词
Thoracic and upper gastrointestinal radiotherapy; Cone-beam CT; Immobilization; Margins; IMAGE-GUIDED RADIOTHERAPY; FLAT-PANEL IMAGER; CELL LUNG-CANCER; COMPUTED-TOMOGRAPHY; CONFORMAL RADIOTHERAPY; PROSTATE-CANCER; ERRORS; LOCALIZATION; VERIFICATION; MARGINS;
D O I
10.1016/j.meddos.2009.09.003
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
We report the setup reproducibility of thoracic and upper gastrointestinal (UGI) radiotherapy (RT) patients for 2 immobilization methods evaluated through cone-beam computed tomography (CBCT) image guidance, and present planning target volume (PTV) margin calculations made on the basis of these observations. Daily CBCT images from 65 patients immobilized in a chestboard (CB) or evacuated cushion (EC) were registered to the planning CT using automatic bony anatomy registration. The standardized region-of-interest for matching was focused around vertebral bodies adjacent to tumor location. Discrepancies >3 mm between the CBCT and CT datasets were corrected before initiation of RT and verified with a second CBCT to assess residual error (usually taken after 90 s of the initial CBCT). Positional data were analyzed to evaluate the magnitude and frequencies of setup errors before and after correction. The setup distributions were slightly different for the CB (797 scans) and EC (757 scans) methods, and the probability of adjustment at a 3-mm action threshold was not significantly different (p = 0.47). Setup displacements >10 mm in any direction were observed in 10% of CB fractions and 16% of EC fractions (p = 0.0008). Residual error distributions after CBCT guidance were equivalent regardless of immobilization method. Using a published formula, the PTV margins for the CB were L/R, 3.3 mm; S/I, 3.5 mm; and A/P, 4.6 mm), and for EC they were L/R, 3.7 mm; S/I, 3.3 mm; and A/P, 4.6 mm. In the absence of image guidance, the CB slightly outperformed the EC in precision. CBCT allows reduction to a single immobilization system that can be chosen for efficiency, logistics, and cost. Image guidance allows for increased geometric precision and accuracy and supports a corresponding reduction in PTV margin. 0 2010 American Association of Medical Dosimetrists.
引用
收藏
页码:287 / 296
页数:10
相关论文
共 50 条
  • [1] CONE-BEAM COMPUTED TOMOGRAPHIC IMAGE GUIDANCE FOR LUNG CANCER RADIATION THERAPY
    Bissonnette, Jean-Pierre
    Purdie, Thomas G.
    Higgins, Jane A.
    Li, Winnie
    Bezjak, Andrea
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (03): : 927 - 934
  • [2] A dual centre study of setup accuracy for thoracic patients based on Cone-Beam CT data
    Nielsen, Tine B.
    Hansen, Vibeke N.
    Westberg, Jonas
    Hansen, Olfred
    Brink, Carsten
    RADIOTHERAPY AND ONCOLOGY, 2012, 102 (02) : 281 - 286
  • [3] 4D cone-beam CT imaging for guidance in radiation therapy: setup verification by use of implanted fiducial markers
    Jin, Peng
    van Wieringen, Niek
    Hulshof, Maarten C. C. M.
    Bel, Arjan
    Alderliesten, Tanja
    MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [4] Quality assurance for the geometric accuracy of cone-beam CT guidance in radiation therapy
    Bissonnette, Jean-Pierre
    Moseley, Doug
    White, Elizabeth
    Sharpe, Michael
    Purdie, Tom
    Jaffray, David A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (01): : S57 - S61
  • [5] High-Performance C-Arm Cone-Beam CT Guidance of Thoracic Surgery
    Schafer, Sebastian
    Otake, Yoshito
    Uneri, Ali
    Mirota, Daniel J.
    Nithiananthan, Sajendra
    Stayman, J. Webster
    Zbijewski, Wojciech
    Kleinszig, Gerhard
    Graumann, Rainer
    Sussman, Marc
    Siewerdsen, Jeffrey H.
    MEDICAL IMAGING 2012: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2012, 8316
  • [6] A quality assurance program for image quality of cone-beam CT guidance in radiation therapy
    Bissonnette, Jean-Pierre
    Moseley, Douglas J.
    Jaffray, David A.
    MEDICAL PHYSICS, 2008, 35 (05) : 1807 - 1815
  • [7] Cone-beam-CT guided radiation therapy:: A model for on-line application
    Oldham, M
    Létourneau, D
    Watt, L
    Hugo, G
    Yan, D
    Lockman, D
    Kim, LH
    Chen, PY
    Martinez, A
    Wong, JW
    RADIOTHERAPY AND ONCOLOGY, 2005, 75 (03) : 271 - 278
  • [8] Low-dose megavoltage cone-beam CT for radiation therapy
    Pouliot, J
    Bani-Hashemi, A
    Chen, J
    Svatos, M
    Ghelmansarai, F
    Mitschke, M
    Aubin, M
    Xia, P
    Morin, O
    Bucci, K
    Roach, M
    Hernandez, P
    Zheng, ZR
    Hristov, D
    Verhey, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (02): : 552 - 560
  • [9] On-line cone beam CT image guidance for vocal cord tumor targeting
    Osman, Sarah O. S.
    de Boer, Hans C. J.
    Astreinidou, Eleftheria
    Gangsaas, Anne
    Heijmen, Ben J. M.
    Levendag, Peter C.
    RADIOTHERAPY AND ONCOLOGY, 2009, 93 (01) : 8 - 13
  • [10] Integration of cone-beam CT in stereotactic body radiation therapy
    Yin, Fang-Fang
    Wang, Zhiheng
    Yoo, Sua
    Wu, Q. Jackie
    Kirkpatrick, John
    Larrier, Nicole
    Meyer, Jeffrey
    Willett, Christopher G.
    Marks, Lawrence B.
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2008, 7 (02) : 133 - 139