Shell and Tube Heat Exchanger Progression Fouling and Its Mitigation Using Chemical Cleaning Process

被引:1
作者
Singh, Dilip Kr [1 ]
Villamayor, Albert [2 ]
Lacheheb, Lotfi [2 ]
机构
[1] MENACI, Hydratight, Benguluru 560080, Karnataka, India
[2] MENACI, Hydratight, Swiss Tower,Unit 902,Jumeirah Lakes Towers, Dubai, U Arab Emirates
来源
3RD INTERNATIONAL CONFERENCE ON ADVANCEMENTS IN AEROMECHANICAL MATERIALS FOR MANUFACTURING: ICAAMM-2020 | 2021年 / 2317卷
关键词
Heat Exchanger; Shell & Tube Heat Exchanger fouling; Effect of Fouling; Crude product fouling and chemical process treatment;
D O I
10.1063/5.0036112
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The heat exchanger calcium sulphate fouling in tube side is the deposition on the tube surfaces which affect the heat transfer. It's found that the oil refinery process plant having an issue of calcium sulphate fouling in heat exchangers due to the crude product which form by hydrous calcium with Sulphur trioxide developed calcium sulphate deposit. The crystalline form of aqueous solution in three forms: gypsum (CaSO4 center dot 2H2O), hemihydrate (CaSO4 center dot 1/2H2O), and anhydrate (CaSO4), which is created by reacting Sulphur trioxide with calcium oxide in the presence of moisture in hydrous form (i.e. CaO + SO3 +2H2O = CaSO4 center dot 2H2O and CaO + SO3 -> CaSO4) form. Calcium sulfate deposits as a crystalline mass which adheres tenaciously to the metal surface, builds up and tends to undesirably reduce the heat transfer characteristics as well as causes plugging. The heat exchanger fouling removal are difficult which is not remove by any normal online cleaning and flushing. The objective of this work is to provide essential understanding of calcium base fouling removal techniques by EDTA chemical cleaning methodology. The mechanical cleaning, needs major shutdown, bundle pulling and retro-jetting which associated with huge cost and additional integrity test. The results of an experimental study on fouling phenomena, environment of fouling, and mitigation of fouling in shell and tube heat exchanger have been clearly explained.
引用
收藏
页数:8
相关论文
共 11 条
[1]  
Abda A. A., 2018, PERFORMANCE ANAL SHE, V12, P563
[2]   Design of shell-and-tube heat exchangers when the fouling depends on local temperature and velocity [J].
Butterworth, D .
APPLIED THERMAL ENGINEERING, 2002, 22 (07) :789-801
[3]  
Coletti F, 2015, INTRO CRUDE OIL FOUL, DOI [10.1016/B978-0- 12-801256-7.00001-4, DOI 10.1016/B978-0-12-801256-7.00001-4]
[4]  
Fahiminia F., 2007, ECI S SER JUL 1 6 ECI S SER JUL 1 6
[5]  
Hou T.K., 2017, HEAT EXCHANGERS ADV, P193, DOI [10.5772/66274, DOI 10.5772/66274]
[6]  
KUSHWAHA DK, 2015, AFR INT C SCI ENG TE
[7]  
Mwaba M.G., 2003, INT J RES GATE
[8]  
Naseema Dr. S. N., 2017, INT J ENG TECHNIQUES, V3
[9]   Fouling phenomenon and its effect on heat exchanger: A review [J].
Ogbonnaya S.K. ;
Ajayi O.O. .
Frontiers in Heat and Mass Transfer, 2017, 9
[10]   Fouling and its effect on the thermal performance of heat exchanger tubes [J].
Sarma P.K. ;
Konijeti R. ;
Subramanyam T. ;
Prasad L.S.V. ;
Korada V.S. ;
Srinivas V. ;
Vedula D.R. ;
Prasad V.S.R.K. .
International Journal of Heat and Technology, 2017, 35 (03) :509-519