AC flashover dynamic model suggestion and insulation level selection under fan-shaped pollution

被引:15
|
作者
Ghayedi, Morteza [1 ]
Shariatinasab, Reza [1 ]
Mirzaie, Mohammad [2 ]
机构
[1] Univ Birjand, Dept Elect & Comp Engn, Birjand 97175, Iran
[2] Babol Noshirvani Univ Technol, Fac Elect & Comp Engn, Babol 47148, Iran
关键词
Dynamic model; Flashover; Insulation level; Non-uniform pollution; Porcelain insulator; NONUNIFORM POLLUTION; PARTIAL-ARC; VOLTAGE; PERFORMANCE; COMPUTATION;
D O I
10.1016/j.ijepes.2021.107438
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The geometry of fan-shaped pollution on the surface of an insulator accounts for two different values of Salt Deposit Density (SDD), conductivity, and resistance on the leeward and windward sides of the insulator. This paper proposes a novel dynamic theory model of AC flashover based on equivalent resistance in the presence of a fan-shaped pollution layer. The proposed model can calculate flashover parameters for different values of the fan-shaped pollution density degree (T) and extension degree (J) considering instantaneous variables in arc progression. In this model, the arc current is formulated using the arc equivalent circuit for a constant arc voltage in terms of arc length propagation. Also, the Form Factor (F) is defined as a function of the arc length by sampling from the desired insulator and curve fitting. To validate the analytical model, some experiments are performed on an insulator unit of suspension porcelain by applying artificial pollution at three levels: light, medium, and heavy. Test results show that the critical flashover voltage (CFO) is reduced by 19% by varying J from 1 (uniform pollution) to 1/15. Moreover, by varying T from 10% to 30%, the CFO decreases by 9%. As the non-uniformity degree increases, the correction factor varies in the range of 0.798 similar to 0.938. The proposed modeling of flashover provided by the paper could be used to perform a dimensioning method on insulators under fan-shaped pollution conditions. Also, the proposed model can be included in the EMTP-type platforms to determine the minimum insulator flashover characteristic that will provide an adequate flashover performance under pollution conditions.
引用
收藏
页数:11
相关论文
共 17 条
  • [1] AC flashover dynamic theoretical and experimental model under fan-shaped and longitudinal pollution on silicone rubber insulator
    Ghayedi, Morteza
    Shariatinasab, Reza
    Mirzaie, Mohammad
    IET Science, Measurement and Technology, 2021, 15 (09): : 719 - 729
  • [2] AC flashover dynamic theoretical and experimental model under fan-shaped and longitudinal pollution on silicone rubber insulator
    Ghayedi, Morteza
    Shariatinasab, Reza
    Mirzaie, Mohammad
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2021, 15 (09) : 719 - 729
  • [3] AC Flashover Performance of Various Types of Insulators under Fan-shaped Non-uniform Pollution
    Zhang, Zhijin
    You, Jinwei
    Zhang, Dongdong
    Jiang, Xingliang
    Hu, Jianlin
    Zhang, Wei
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (03) : 1760 - 1768
  • [4] AC Flashover Performance of Post Insulator With Fan-shaped Non-uniform Pollution
    Zhang Z.
    Xiang Y.
    Qiao X.
    Jiang X.
    Wu J.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2019, 39 (24): : 7385 - 7393
  • [5] AC flashover performance of different shed configurations of composite insulators under fan-shaped non-uniform pollution
    Zhang, Zhijin
    Qiao, Xinhan
    Zhang, Yi
    Tian, Liang
    Zhang, Dongdong
    Jiang, Xingliang
    HIGH VOLTAGE, 2018, 3 (03): : 199 - 206
  • [6] Experimental investigation on composite insulators AC flashover performance with fan-shaped non-uniform pollution under electro-thermal stress
    Savadkoohi, Ehsan Mohammadi
    Mirzaie, Mohammad
    Seyyedbarzegar, SeyyedMeysam
    Mohammadi, Mohsen
    Khodsuz, Masume
    Pashakolae, Mehrdad Ghorbani
    Ghadikolaei, Milad Biazar
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 121
  • [7] Study on the DC Flashover Performance of Various Types of Insulators With Fan-Shaped Nonuniform Pollution
    Zhang, Zhijin
    Zhang, Dongdong
    You, Jinwei
    Zhao, Jiayao
    Jiang, Xingliang
    Hu, Jianlin
    IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (04) : 1871 - 1879
  • [8] DC Flashover Performance of Insulator String with Fan-shaped Non-uniform Pollution
    Zhang, Zhijin
    Zhang, Dongdong
    Zhang, Wei
    Yang, Chao
    Jiang, Xingliang
    Hu, Jianlin
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (01) : 177 - 184
  • [9] Investigation and analysis of AC flashover voltage of SiR insulators under longitudinal and fan-shaped non-uniform pollutions
    Samakosh, Jaber Dadashizadeh
    Mirzaie, Mohammad
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2019, 108 : 382 - 391
  • [10] Influence of fan-shaped non-uniform pollution on the electrical property of typical type HVDC insulator and insulation selection
    Zhang, Dongdong
    Zhang, Zhijin
    Jiang, Xingliang
    Zhang, Wei
    Zhao, Jiayao
    Bi, Maoqiang
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (14) : 3555 - 3562