Environmental Testing of a FBG Sensor System for Structural Health Monitoring of Building and Transport Structures

被引:9
|
作者
Capova, Kristyna [1 ]
Velebil, Lukas [1 ]
Vaelak, Jan [1 ]
Dvorak, Milan [2 ]
Sasek, Ladislav [2 ]
机构
[1] Czech Tech Univ, Univ Ctr Energy Efficient Bldg, Bustehrad 27343, Czech Republic
[2] Safibra Sro, Ricany 25101, Czech Republic
来源
3RD INTERNATIONAL CONFERENCE ON STRUCTURAL INTEGRITY (ICSI 2019) | 2019年 / 17卷
关键词
FBG; fibre optic sensor; structural health monitoring; environmental testing; mechanical loading test; glued laminated timber;
D O I
10.1016/j.prostr.2019.08.097
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Recently, there has been an increased interest in structural health monitoring (SHM) of building and transport structures. Standard strain gauges placed on a beam surface are mostly used to monitor the mechanical stresses of timber or concrete structures. However, these sensors are susceptible to mechanical damage, electromagnetic interference or negative influences of the measured data during the measurement, such as temperature variations or potential loss of data due to explosive environment. The fibre optic sensor system offers a more suitable and reliable solution the sensors can be integrated directly into the load bearing structure during its production and thus protected by the construction material against ambient environmental conditions. The first part of this paper presents series of environmental tests of a measuring system based on Fibre Bragg Grating principle performed from 2016 to 2018 in a climate chamber. The chamber can generate defined humidity and/or temperature cycles, which can simulate the behavior of the structure under real environmental conditions. The tested fibre optic sensor system is suitable for load bearing timber (glued laminated timber beams) and concrete structures. In the second part of this paper, mechanical loading tests of glued laminated timber beam with integrated fiber optic sensors performed in 2016, 2017 and 2018 are presented. The article describes the design of test cycles, gives the results of testing, and is concluded with the discussion of given results together with the outline of the future research directions. (C) 2019 The Authors. Published by Elsevier B.V.
引用
收藏
页码:726 / 733
页数:8
相关论文
共 50 条
  • [1] Environmental testing of wireless sensor system for structural health monitoring of civil infrastructure
    Fuchs, Michael P.
    Janoyan, Kerop D.
    Sazonov, Edward S.
    Krishnamurthy, Vidya
    Jha, Ratan
    Cross, Kevin
    SMART STRUCTURES AND MATERIALS 2006: SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL , AND AEROSPACE SYSTEMS, PTS 1 AND 2, 2006, 6174
  • [2] Structural health monitoring system using FBG sensor for simultaneous detection of acceleration and strain
    Hayano, H
    Mita, A
    SMART STRUCTURES AND MATERIALS 2005: SENSORS AND SMART STRUCTURES TECHNOLOGIES FOR CIVIL, MECHANICAL, AND AEROSPACE, PTS 1 AND 2, 2005, 5765 : 624 - 633
  • [3] Analysis of the strain transfer in a new FBG sensor for Structural Health Monitoring
    Torres, Benjamin
    Paya-Zaforteza, Ignacio
    Calderon, Pedro A.
    Adam, Jose M.
    ENGINEERING STRUCTURES, 2011, 33 (02) : 539 - 548
  • [4] Structural health monitoring for smart composites using embedded FBG sensor technology
    Lau, K. -T.
    MATERIALS SCIENCE AND TECHNOLOGY, 2014, 30 (13A) : 1642 - 1654
  • [5] Development of FBG sensors for structural health monitoring in civil infrastructures
    Zhou, Z
    Ou, JP
    SENSING ISSUES IN CIVIL STRUCTURAL HEALTH MONITORING, 2005, : 197 - 206
  • [6] Mechanical strength of FBG sensor exposed to cyclic thermal load for structural health monitoring
    Kim, Heonyoung
    Kang, Donghoon
    Kim, Dae-Hyun
    SMART STRUCTURES AND SYSTEMS, 2017, 19 (03) : 335 - 340
  • [7] An innovative embedded wireless sensor network system for the structural health monitoring of RC structures
    Angrisani, L.
    Lo Moriello, R. Schiano
    Bonavolonta, F.
    Gallucci, L.
    Menna, C.
    Asprone, D.
    Fabbrocino, F.
    2017 IEEE 3RD INTERNATIONAL FORUM ON RESEARCH AND TECHNOLOGIES FOR SOCIETY AND INDUSTRY (RTSI), 2017, : 306 - 309
  • [8] Structural Health Monitoring using an Embedded PZT-FBG Ultrasonic Sensor Array
    Botsev, Y.
    Arad, E.
    Tur, M.
    Kressel, I.
    Ben-Simon, U.
    Gail, S.
    Osmont, D.
    PROCEEDINGS OF THE FOURTH EUROPEAN WORKSHOP ON STRUCTURAL HEALTH MONITORING 2008, 2008, : 649 - 656
  • [9] Theoretical investigation of positional influence of FBG sensors for structural health monitoring of offshore structures
    Johny, Jincy
    Summers, Jade
    Bhavsar, Kaushalkumar
    Joseph, Ginson P.
    Fung, Wai Keung
    Prabhu, Radhakrishna
    OCEANS 2017 - ABERDEEN, 2017,
  • [10] Fibre optic sensors for the structural health monitoring of building structures
    Bremer, K.
    Wollweber, M.
    Weigand, F.
    Rahlves, M.
    Kuhne, M.
    Helbig, R.
    Roth, B.