Evaluation of double-tuned single-sided planar microcoils for the analysis of small 13C enriched biological samples using 1H-13C 2D heteronuclear correlation NMR spectroscopy

被引:7
作者
Moxley-Paquette, Vincent [1 ]
Wu, Bing [1 ]
Lane, Daniel [1 ]
Bastawrous, Monica [1 ]
Ning, Paris [1 ]
Soong, Ronald [1 ]
De Castro, Peter [2 ]
Kovacevic, Ivan [2 ]
Frei, Thomas [2 ]
Stuessi, Juerg [2 ]
Al Adwan-Stojilkovic, Danijela [2 ]
Graf, Stephan [2 ]
Vincent, Franck [2 ]
Schmidig, Daniel [2 ]
Kuehn, Till [2 ]
Kuemmerle, Rainer [2 ]
Beck, Armin [2 ]
Fey, Michael [3 ]
Bermel, Wolfgang [4 ]
Busse, Falko [4 ]
Gundy, Marcel [5 ]
Boenisch, Holger [5 ]
Heumann, Hermann [5 ]
Nashman, Ben [6 ]
Majumdar, Rudraksha Dutta [6 ]
Lacerda, Andressa [6 ]
Simpson, Andre J. [1 ]
机构
[1] Univ Toronto, Environm NMR Ctr, 1265 Mil Trail, Toronto, ON, Canada
[2] Bruker BioSpin AG, Magnet Resonance Spect Div, Fallanden, Switzerland
[3] Bruker Corp, Magnet Resonance Spect Div, Billerica, MA USA
[4] Bruker Biospin GmbH, Magnet Resonance Spect Div, Rheinstetten, Germany
[5] Silantes GmbH, Res & Dev, Munich, Germany
[6] Synex Med, Res & Dev, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
C-13 enriched mass limited biological samples; heteronuclear 2D NMR; metabolites; surface microcoils; IN-VIVO NMR; DAPHNIA-MAGNA RESPONSES; SOLUTION-STATE NMR; SUBLETHAL EXPOSURE; TOXICITY; METABOLOMICS; IDENTIFICATION; PROTON;
D O I
10.1002/mrc.5227
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Microcoils provide a cost-effective approach to improve detection limits for mass-limited samples. Single-sided planar microcoils are advantageous in comparison to volume coils, in that the sample can simply be placed on top. However, the considerable drawback is that the RF field that is produced by the coil decreases with distance from the coil surface, which potentially limits more complex multi-pulse NMR pulse sequences. Unfortunately, H-1 NMR alone is not very informative for intact biological samples due to line broadening caused by magnetic susceptibility distortions, and H-1-C-13 2D NMR correlations are required to provide the additional spectral dispersion for metabolic assignments in vivo or in situ. To our knowledge, double-tuned single-sided microcoils have not been applied for the 2D H-1-C-13 analysis of intact C-13 enriched biological samples. Questions include the following: Can H-1-C-13 2D NMR be performed on single-sided planar microcoils? If so, do they still hold sensitivity advantages over conventional 5 mm NMR technology for mass limited samples? Here, 2D H-1-C-13 HSQC, HMQC, and HETCOR variants were compared and then applied to C-13 enriched broccoli seeds and Daphnia magna (water fleas). Compared to 5 mm NMR probes, the microcoils showed a sixfold improvement in mass sensitivity (albeit only for a small localized region) and allowed for the identification of metabolites in a single intact D. magna for the first time. Single-sided planar microcoils show practical benefit for H-1-C-13 NMR of intact biological samples, if localized information within similar to 0.7 mm of the 1 mm I.D. planar microcoil surface is of specific interest.
引用
收藏
页码:386 / 397
页数:12
相关论文
共 59 条
[21]  
Haase A, 2000, CONCEPT MAGNETIC RES, V12, P361, DOI 10.1002/1099-0534(2000)12:6<361::AID-CMR1>3.0.CO
[22]  
2-L
[23]   Zooplankton egg banks as biotic reservoirs in changing environments [J].
Hairston, NG .
LIMNOLOGY AND OCEANOGRAPHY, 1996, 41 (05) :1087-1092
[24]   High-precision frequency measurements: indispensable tools at the core of the molecular-level analysis of complex systems [J].
Hertkorn, N. ;
Ruecker, C. ;
Meringer, M. ;
Gugisch, R. ;
Frommberger, M. ;
Perdue, E. M. ;
Witt, M. ;
Schmitt-Kopplin, P. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (05) :1311-1327
[25]  
JANSSEN CR, 1993, ENVIRON TOXICOL CHEM, V12, P711, DOI [10.1897/1552-8618(1993)12[711:RTSTFA]2.0.CO
[26]  
2, 10.1002/etc.5620120413]
[27]   High-throughput microcoil NMR of compound libraries using zero-dispersion segmented flow analysis [J].
Kautz, RA ;
Goetzinger, WK ;
Karger, BL .
JOURNAL OF COMBINATORIAL CHEMISTRY, 2005, 7 (01) :14-20
[28]   Sample concentration and separation for nanoliter-volume NMR spectroscopy using capillary isotachophoresis [J].
Kautz, RA ;
Lacey, ME ;
Wolters, AM ;
Foret, F ;
Webb, AG ;
Karger, BL ;
Sweedler, JV .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2001, 123 (13) :3159-3160
[29]   PURE ABSORPTION GRADIENT ENHANCED HETERONUCLEAR SINGLE QUANTUM CORRELATION SPECTROSCOPY WITH IMPROVED SENSITIVITY [J].
KAY, LE ;
KEIFER, P ;
SAARINEN, T .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1992, 114 (26) :10663-10665
[30]   On-line NMR detection of microgram quantities of heparin-derived oligosaccharides and their structure elucidation by microcoil NMR [J].
Korir, Albert K. ;
Larive, Cynthia K. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 388 (08) :1707-1716