Application of the Stationary Wavelet Transform to Reduce Power-line Interference in Atrial Electrograms

被引:0
|
作者
Martinez-Iniesta, Miguel [1 ]
Rodenas, Juan [1 ]
Alcaraz, Raul [1 ]
Rieta, Jose J. [2 ]
机构
[1] Univ Castilla La Mancha, Res Grp Elect Biomed & Telecomm Engn, Ciudad Real, Spain
[2] Univ Politecn Valencia, Elect Engn Dept, BioMIT Org, Valencia, Spain
来源
关键词
FIBRILLATION; SIGNALS; MECHANISMS;
D O I
10.22489/CinC.2017.112-049
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The atrial electrical activity analysis is nowadays playing a key role to improve current knowledge about the mechanisms triggering and maintaining atrial arrhythmias, such as atrial fibrillation (AF). Indeed, the intraatrial electrograms (EGMs) provide essential information to guide the prevailing cornerstone treatment of AF, i.e., catheter ablation. Bearing in mind that cardiac electrophysiology laboratories are plenty of technology, such a kind of operating rooms are a very adverse environment when it comes to avoid power-line interference in EGM recordings. However, the reduction of this nuisance signal deserves more attention. Thus, aimed at reducing power-line noise but, at the same time, preserving the original EGM morphology, a novel algorithm based on the stationary Wavelet transform (SWT) is proposed. To validate the method, 150 bipolar EGMs with 10 seconds in length have been synthesized with different noise levels. The original and denoised EGMs have then been compared by means of an adaptive signed correlation index (ASCI), computed both in time and frequency domains. The obtained results have shown improvements between 9% and 17% for the proposed method regarding a reference notch filtering. Consequently, this new algorithm may enable more reliable and truthful further analyses of atrial EGMs.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Investigation of the immunity of computer equipment to the power-line electromagnetic interference
    Gizatullin, Z. M.
    Gizatullin, R. M.
    JOURNAL OF COMMUNICATIONS TECHNOLOGY AND ELECTRONICS, 2016, 61 (05) : 546 - 550
  • [22] An adaptive power-line interference removal technique for biopotential measurement
    Lin, Y.-D., 2000, Institute of Biomedical Engineering (12):
  • [23] On the application of wavelet transform for symmetrical components computations in the presence of stationary and non-stationary power quality disturbances
    Morsi, W. G.
    El-Hawary, M. E.
    ELECTRIC POWER SYSTEMS RESEARCH, 2011, 81 (07) : 1373 - 1380
  • [24] The application of stationary wavelet transform in crop image segmentation
    Cai Zhenjiang
    Hu Yihua
    Sun Yumei
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 1170 - 1172
  • [25] Robust suppression of nonstationary power-line interference in electrocardiogram signals
    Li, Guojun
    Zeng, Xiaopin
    Zhou, Xiaona
    Zhou, Yu
    Liu, Guojin
    Zhou, Xichuan
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (07) : 1151 - 1169
  • [26] Investigation of the immunity of computer equipment to the power-line electromagnetic interference
    Z. M. Gizatullin
    R. M. Gizatullin
    Journal of Communications Technology and Electronics, 2016, 61 : 546 - 550
  • [27] Power-line interference elimination from ECG in case of non-multiplicity between the sampling rate and the power-line frequency
    Mihov, Georgy
    Dotsinsky, Ivan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2008, 3 (04) : 334 - 340
  • [28] POWER-LINE CARRIER INTERFERENCE FROM HVDC CONVERTER TERMINALS
    TATRO, PJ
    ERIKSSON, KA
    RAY, R
    ROSENQVIST, R
    SHORE, NL
    ADAMSON, KA
    EITZMANN, MA
    SMEAD, M
    IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (03) : 827 - 840
  • [29] Power-line interference detection and suppression in ECG signal processing
    Lin, Yue-Der
    Hu, Yu Hen
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2008, 55 (01) : 354 - 357
  • [30] An Approach to Successful Power-line Interference Suppression in ECG Signals
    Dotsinsky I.
    Dotsinsky, Ivan, 1600, Institute of Biophysics and Biomedical Engineering (26): : 83 - 92