10-year experience with the ATS mechanical valve in the mitral position

被引:15
|
作者
Stefanidis, C [1 ]
Nana, AM [1 ]
De Cannière, D [1 ]
Antoine, M [1 ]
Jansens, JL [1 ]
Huynh, CH [1 ]
Le Clerc, JL [1 ]
机构
[1] Free Univ Brussels, Erasme Hosp, Dept Cardiac Surg, B-1070 Brussels, Belgium
来源
ANNALS OF THORACIC SURGERY | 2005年 / 79卷 / 06期
关键词
D O I
10.1016/j.athoracsur.2005.01.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The ATS Medical Open Pivot mechanical heart valve was introduced in 1992. Previous reports have focused on the low rate of thromboembolic complications in the aortic position. The purpose of this retrospective study is to analyze the rate of midterm thromboembolic events and other valve-related complications when the ATS Open Pivot valve is implanted in the mitral position. Methods. Between June 1992 and June 2002, 177 patients (63 male and 114 female; mean age 57.5 years) underwent mitral replacement with an ATS Open Pivot mechanical heart valve. Preoperatively, 17 patients (10%) were in New York Heart Association functional class II, 117 patients (66%) in class III, and 43 patients (24%) in class IV. Seventy-four patients (42%) were in chronic atrial fibrillation. Seventy-f our mitral valve replacements (42%) were associated with other cardiac procedures. Etiologies included degenerative disease (56%), rheumatic disease (38%), and endocarditis (6%). On the second postoperative day, 100 mg acetylsalicylic acid and oral acenocournarol (Sintrom) was introduced to obtain a target INR of 2.0 to 3.0. All patients were followed up by one cardiologist and underwent annual transthoracic echocardiographic examination. Results. Percent follow-up was 90.4%. Data represent 724 total patient-years. Mean follow-up was 48 +/- 34 months (range, 1 to 119). Operative morbidity was 15%. Overall hospital mortality was 2.8% (5 patients). At hospital discharge, the mean INR for all the patients was 2.38 +/- 0.68 (range, 1.32 to 6.44). Five early neurologic complications occurred: 3 transient cerebrovascular accidents and 2 strokes. Three late transient cerebrovascular ischemic accidents occurred at 3, 4, and 6 years, respectively. No other complications such as paravalvular leak, valve dysfunction, thrombosis, or valve explant occurred. Postoperative echocardiographic data revealed low mean pressure gradient as related to the valvular size. Conclusions. The ATS Medical Open Pivot mitral valve demonstrates low rates of bleeding, thromboembolic, and other valve-related complications. (c) 2005 by The Society of Thoracic Surgeons.
引用
收藏
页码:1934 / 1938
页数:5
相关论文
共 50 条
  • [31] BOTULISM - 10-YEAR EXPERIENCE
    CHERINGTON, M
    ARCHIVES OF NEUROLOGY, 1974, 30 (06) : 432 - 437
  • [32] SYRINGOMYELIA - A 10-YEAR EXPERIENCE
    BUTLER, EG
    GILLIGAN, BS
    SIU, K
    STARK, RJ
    WODAK, J
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1988, 18 (03): : 475 - 475
  • [33] A 10-YEAR EXPERIENCE WITH URETEROILEOSTOMY
    COHEN, SM
    PERSKY, L
    ARCHIVES OF SURGERY, 1967, 95 (02) : 278 - &
  • [34] SURGERY FOR INFECTIVE MITRAL VALVE ENDOCARDITIS: A 10 YEAR SINGLE CENTRE EXPERIENCE
    Jahangeer, S.
    Hannan, M.
    Blake, G.
    Healy, D.
    Redmond, M.
    McGuinness, J.
    Javadpour, H.
    Chughtai, Z. J.
    Nolke, L.
    McCarthy, J.
    HEART, 2015, 101 : A16 - A16
  • [35] 10-YEAR EXPERIENCE WITH THE ST-JUDE MEDICAL VALVE FOR PRIMARY VALVE-REPLACEMENT
    CZER, LSC
    CHAUX, A
    MATLOFF, JM
    DEROBERTIS, MA
    NESSIM, SA
    SCARLATA, D
    KHAN, SS
    KASS, RM
    TSAI, TP
    BLANCHE, C
    GRAY, RJ
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1990, 100 (01): : 44 - 55
  • [36] Fifteen years of experience with ATS mechanical heart valve prostheses
    Sezai, Akira
    Hata, Mitsumasa
    Niino, Tetsuya
    Yoshitake, Isamu
    Kasamaki, Yuji
    Hirayama, Atsushi
    Minami, Kazutomo
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (06): : 1494 - 1500
  • [37] Twelve years of experience with the ATS mechanical heart valve prostheses
    Taniguchi S.
    Hashizume K.
    Ariyoshi T.
    Hisata Y.
    Tanigawa K.
    Miura T.
    Odate T.
    Matsukuma S.
    Nakaji S.
    Eishi K.
    General Thoracic and Cardiovascular Surgery, 2012, 60 (9) : 561 - 568
  • [38] The initial experience with the ATS medical mechanical cardiac valve prosthesis
    Emery, RW
    Van Nooten, GJ
    Tesar, PJ
    ANNALS OF THORACIC SURGERY, 2003, 75 (02): : 444 - 452
  • [39] EARLY CARDIAC-VALVE REPLACEMENT IN INFECTIVE ENDOCARDITIS - A 10-YEAR EXPERIENCE
    SURYAPRANATA, H
    ROELANDT, J
    HAALEBOS, M
    DEGENER, J
    BOS, E
    HUGENHOLTZ, PG
    EUROPEAN HEART JOURNAL, 1987, 8 (05) : 464 - 470
  • [40] 10-YEAR EXPERIENCE WITH FASCIA-LATA REPLACEMENT OF AORTIC-VALVE
    ROTHLIN, M
    WALKER, P
    GADIENT, A
    SENNING, A
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1973, 103 (50) : 1802 - 1804