Coherent noise reduction in digital holographic phase contrast microscopy by slightly shifting object

被引:77
作者
Pan, Feng [1 ]
Xiao, Wen [1 ]
Liu, Shuo [1 ]
Wang, FanJing [1 ]
Rong, Lu [1 ]
Li, Rui [1 ]
机构
[1] Beihang Univ, Sch Instrumentat Sci & Optoelect Engn, Beijing 100191, Peoples R China
基金
美国国家科学基金会;
关键词
SPECKLE NOISE; SPATIAL COHERENCE; RECONSTRUCTION; IMPROVEMENT; CELLS; LIGHT;
D O I
10.1364/OE.19.003862
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A method to reduce coherent noise in digital holographic phase contrast microscopy is proposed. By slightly shifting the specimen, a series of digital holograms with different coherent noise patterns is recorded. Each hologram is reconstructed individually, while the different phase tilts of the reconstructed complex amplitudes due to the specimen shifts are corrected in the hologram plane by using numerical parametric lens method. Afterward, the lateral displacements of the phase maps from different holograms are compensated in the image plane by using digital image registration method. Thus, all phase images have same distribution, but uncorrelated coherent noise patterns. By a proper averaging procedure, the coherent noise of phase contrast image is reduced significantly. The experimental results are given to confirm the proposed method. (C) 2011 Optical Society of America
引用
收藏
页码:3862 / 3869
页数:8
相关论文
共 25 条
[1]   Reduction of speckle noise in the reconstructed image of digital holography [J].
Cai, Xiao-ou .
OPTIK, 2010, 121 (04) :394-399
[2]   Characterization of microlenses by digital holographic microscopy [J].
Charrière, F ;
Kühn, J ;
Colomb, T ;
Montfort, F ;
Cuche, E ;
Emery, Y ;
Weible, K ;
Marquet, P ;
Depeursinge, C .
APPLIED OPTICS, 2006, 45 (05) :829-835
[3]   Automatic procedure for aberration compensation in digital holographic microscopy and applications to specimen shape compensation [J].
Colomb, T ;
Cuche, E ;
Charrière, F ;
Kühn, J ;
Aspert, N ;
Montfort, F ;
Marquet, P ;
Depeursinge, C .
APPLIED OPTICS, 2006, 45 (05) :851-863
[4]   Digital holographic microscopy with reduced spatial coherence for three-dimensional particle flow analysis [J].
Dubois, F ;
Callens, N ;
Yourassowsky, C ;
Hoyos, M ;
Kurowski, P ;
Monnom, O .
APPLIED OPTICS, 2006, 45 (05) :864-871
[5]   Partial spatial coherence effects in digital holographic microscopy with a laser source [J].
Dubois, F ;
Requena, MLN ;
Minetti, C ;
Monnom, O ;
Istasse, E .
APPLIED OPTICS, 2004, 43 (05) :1131-1139
[6]   Long-working-distance synthetic aperture Fresnel off-axis digital holography [J].
Feng, Pan ;
Wen, Xiao ;
Lu, Rong .
OPTICS EXPRESS, 2009, 17 (07) :5473-5480
[7]   Reduction of speckle noise in digital holography by using digital image processing [J].
Garcia-Sucerquia, J ;
Ramírez, JAH ;
Prieto, DV .
OPTIK, 2005, 116 (01) :44-48
[8]   Coherence effects in digital in-line holographic microscopy [J].
Gopinathan, Unnikrishnan ;
Pedrini, Giancarlo ;
Osten, Wolfgang .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2008, 25 (10) :2459-2466
[9]   Efficient subpixel image registration algorithms [J].
Guizar-Sicairos, Manuel ;
Thurman, Samuel T. ;
Fienup, James R. .
OPTICS LETTERS, 2008, 33 (02) :156-158
[10]  
Kang X, 2008, CHIN OPT LETT, V6, P100