Strategies for the elimination of matrix effects in the liquid chromatography tandem mass spectrometry analysis of the lipophilic toxins okadaic acid and azaspiracid-1 in molluscan shellfish

被引:57
作者
Kilcoyne, Jane [1 ]
Fux, Elie [2 ]
机构
[1] Marine Inst Renville, Oranmore, Galway, Ireland
[2] US FDA, Gulf Coast Seafood Lab, Dauphin Isl, AL 36528 USA
关键词
Lipophilic marine biotoxins; Azaspiracid; Okadaic acid; LC-MS; On-line SPE; Matrix effects; MYTILUS-EDULIS; SPORTS DRINKS; SOFT DRINKS; PERFORMANCE; MUSSELS; RESIDUES;
D O I
10.1016/j.chroma.2010.09.020
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Considerable efforts are being made worldwide to replace in vivo assays with instrumental methods of analysis for the monitoring of marine biotoxins in shellfish Analysis of these compounds by the preferred technique of liquid chromatography tandem mass spectrometry (LC-MS/MS) is challenged by matrix effects associated with the shellfish tissues In methods validation assessment of matrix interferences is imperative to ensure the validity and accuracy of results being produced Matrix Interferences for the analysis of okadaic acid (OA) and azaspiracid 1 (AZA1) were assessed using acidic methods on electrospray triple stage quadrupole (TSQ) and hybrid quadrupole time of flight (QToF) instruments by the use of matrix matched standards for different tissue types Using an acidic method no matrix interference and suppression was observed on the TSQ for OA and AZA1 respectively whilst the opposite was observed on the QToF matrix enhancement for OA and no matrix interference for AZA1 The suppression of AZAs on the TSQ was found to be due to interfering compounds being carried over from previous injections The degree of suppression is very much dependant on the tissue type ranging from 15 to 70% Several strategies were evaluated to eliminate these interferences including the partitioning of the extract with hexane optimisation of the chromatographic method and the use of on-line SPE Hexane clean up did not have any impact on matrix effects The use of an alkaline method and a modified acidic method eliminated matrix suppression for AZA1 on the TSQ instrument while an on-line SPE method proved to be effective for matrix enhancement of OA on the QToF (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:7123 / 7130
页数:8
相关论文
共 40 条
[1]  
ALVAREZ G, 2009, TOXICON, V55, P692
[2]  
[Anonymous], 2001, Guidance for industry: bioanalytical method validation
[3]  
[Anonymous], HARM GUID SINGL LAB
[4]  
AOAC, 2002, GUID SINGL LAB VAL C
[5]  
Aune Tore, 1993, P87
[6]  
Baker R, 2010, EFSA J, V8, DOI [10.2903/j.efsa.2010.1495, 10.2903/j.efsa.2009.306r]
[7]  
*EUR FOOD SAF AUTH, 2009, EFSA J, V1016, P1
[8]  
*EURACHEM, 1998, EURACHEM GUID LAB GU
[9]  
*FAO, REP JOINT FAO IOC WH
[10]   Approaches to the evaluation of matrix effects in the liquid chromatography-mass spectrometry (LC-MS) analysis of three regulated lipophilic toxin groups in mussel matrix (Mytilus edulis) [J].
Fux, E. ;
Rode, D. ;
Bire, R. ;
Hess, P. .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2008, 25 (08) :1024-1032