Detection of Subclinical Keratoconus With a Validated Alternative Method to Corneal Densitometry

被引:10
|
作者
Consejot, Alejandra [1 ,2 ]
Jimenez-Garcia, Marta [3 ,4 ]
Issarti, Ikram [3 ,4 ]
Rozema, Jos J. [3 ,4 ]
机构
[1] Univ Zaragoza, Dept Appl Phys, C Pedro Cerbuna 12, Zaragoza 50009, Spain
[2] Polish Acad Sci, Inst Phys Chem, Warsaw, Poland
[3] Antwerp Univ Hosp, Dept Ophthalmol, Edegem, Belgium
[4] Univ Antwerp, Dept Med & Hlth Sci, Antwerp, Belgium
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2021年 / 10卷 / 09期
关键词
keratoconus; subclinical keratoconus; forme fruste; densitometry; statistical image analysis; DIAGNOSIS; TOMOGRAPHY; ECTASIA; RISK;
D O I
10.1167/tvst.10.9.32
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To enhance the current standards of subclinical keratoconus screening based on the statistical modeling of the pixel intensity distribution of Scheimpflug images. Methods: Scheimpflug corneal tomographies corresponding to 25 corneal meridians of 60 participants were retrospectively collected and divided into three groups: controls (20 eyes), subclinical keratoconus (20 eyes), and clinical keratoconus (20 eyes). Only right eyes were selected. After corneal segmentation, pixel intensities of the stromal tissue were statistically modeled using aWeibull probability density function from which parameter alpha (pixel brightness) was derived. Further, data were transformed to polar coordinates, smoothed, and interpolated to build amap of the corneal alpha parameter. The discriminative power of the method was analyzed using receiver operating characteristic curves. Results: The proposed platform-independent method achieved a higher performance in discriminating subclinical keratoconus from control eyes (90.0% sensitivity, 95.0% specificity, 0.97 area under the curve [AUC]) than the standard method (Belin-Ambrosio enhanced ectasia display), which uses only corneal morphometry (85.0% sensitivity, 85.0% specificity, 0.80 AUC). Conclusions: Analysis of light backscatter at the cornea successfully discriminates subclinical keratoconus from control eyes, upgrading the results previously reported in the literature. Translational Relevance: The proposed methodology has the potential to support clinicians in the detection of keratoconus before showing clinical signs.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Corneal Stromal Densitometry Evolution in a Clinical Model of Cellular Therapy for Advanced Keratoconus
    El Zarif, Mona
    Alio del Barrio, Jorge L.
    Mingo, David
    Jawad, Karim A.
    Alio, Jorge L.
    CORNEA, 2023, 42 (03) : 332 - 343
  • [42] Corneal densitometry in bilateral keratoconus patients with unilateral corneal Vogt's striae: a contralateral eye study
    Wei, Shengsheng
    Li, Jing
    Li, Yong
    Zhang, Yaohua
    Cai, Yan
    Du, Jing
    Liu, Jianguo
    Wang, Yan
    INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (03) : 885 - 897
  • [43] Corneal densitometry in bilateral keratoconus patients with unilateral corneal Vogt’s striae: a contralateral eye study
    Shengsheng Wei
    Jing Li
    Yong Li
    Yaohua Zhang
    Yan Cai
    Jing Du
    Jianguo Liu
    Yan Wang
    International Ophthalmology, 2023, 43 : 885 - 897
  • [44] Detection of Subclinical Keratoconus Using Biometric Parameters
    Sebastian Velazquez-Blazquez, Jose
    Cavas-Martinez, Francisco
    Alio del Barrio, Jorge
    Fernandez-Pacheco, Daniel G.
    Canavate, Francisco J. F.
    Parras-Burgos, Dolores
    Alio, Jorge
    BIOINFORMATICS AND BIOMEDICAL ENGINEERING (IWBBIO 2019), PT II, 2019, 11466 : 490 - 501
  • [45] Subclinical keratoconus detection with three-dimensional (3-D) morphogeometric and volumetric analysis
    Toprak, Ibrahim
    Cavas, Francisco
    Velazquez, Jose S.
    Alio del Barrio, Jorge L.
    Alio, Jorge L.
    ACTA OPHTHALMOLOGICA, 2020, 98 (08) : E933 - E942
  • [46] Systematic detection of keratoconus in OCT: corneal and epithelial thickness maps
    Yuecekul, Burcu
    Dick, H. Burkhard
    Taneri, Suphi
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (12) : 1360 - 1365
  • [47] SmartKC: Smartphone-based Corneal Topographer for Keratoconus Detection
    Gairola, Siddhartha
    Bohra, Murtuza
    Shaheer, Nadeem
    Jayaprakash, Navya
    Joshi, Pallavi
    Balasubramaniam, Anand
    Murali, Kaushik
    Kwatra, Nipun
    Jain, Mohit
    PROCEEDINGS OF THE ACM ON INTERACTIVE MOBILE WEARABLE AND UBIQUITOUS TECHNOLOGIES-IMWUT, 2021, 5 (04):
  • [48] A new approach to keratoconus detection based on corneal morphogeometric analysis
    Cavas-Martinez, Francisco
    Bataille, Laurent
    Fernandez-Pacheco, Daniel G.
    Canavate, Francisco J. F.
    Alio, Jorge L.
    PLOS ONE, 2017, 12 (09):
  • [49] Evaluation of the diagnostic ability of vector parameters characterizing the corneal astigmatism and regularity in clinical and subclinical keratoconus
    Martinez-Abad, Antonio
    Pinero, David P.
    Ruiz-Fortes, Pedro
    Artola, Alberto
    CONTACT LENS & ANTERIOR EYE, 2017, 40 (02) : 88 - 96
  • [50] Influencing Factors in Corneal Densitometry Recovery After Accelerated Cross-Linking for Keratoconus
    Huang, Kuan-, I
    Yeh, Cyuan-Yi
    Hu, Chao-Chien
    Cheng, Sheng-Fu
    JOURNAL OF OPHTHALMOLOGY, 2025, 2025 (01)