摘要
Purpose: To enhance the current standards of subclinical keratoconus screening based on the statistical modeling of the pixel intensity distribution of Scheimpflug images. Methods: Scheimpflug corneal tomographies corresponding to 25 corneal meridians of 60 participants were retrospectively collected and divided into three groups: controls (20 eyes), subclinical keratoconus (20 eyes), and clinical keratoconus (20 eyes). Only right eyes were selected. After corneal segmentation, pixel intensities of the stromal tissue were statistically modeled using aWeibull probability density function from which parameter alpha (pixel brightness) was derived. Further, data were transformed to polar coordinates, smoothed, and interpolated to build amap of the corneal alpha parameter. The discriminative power of the method was analyzed using receiver operating characteristic curves. Results: The proposed platform-independent method achieved a higher performance in discriminating subclinical keratoconus from control eyes (90.0% sensitivity, 95.0% specificity, 0.97 area under the curve [AUC]) than the standard method (Belin-Ambrosio enhanced ectasia display), which uses only corneal morphometry (85.0% sensitivity, 85.0% specificity, 0.80 AUC). Conclusions: Analysis of light backscatter at the cornea successfully discriminates subclinical keratoconus from control eyes, upgrading the results previously reported in the literature. Translational Relevance: The proposed methodology has the potential to support clinicians in the detection of keratoconus before showing clinical signs.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Corneal densitometry changes in keratoconus patients after intrastromal corneal ring segments implantation
    Basiony, Ahmed I.
    Abdulfattah, Mohammad M. E. Mohammad
    Ibrahim, Asmaa M.
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2024, 117 (01) : 28 - 38
  • [32] Corneal densitometry in patients with keratoconus undergoing intrastromal Ferrara ring implantation
    Rodrigues, Pablo Felipe
    Moscovici, Bernardo Kaplan
    Ferrara, Guilherme
    Lamazales, Luciano
    Freitas, Marcela Mara Silva
    Torquetti, Leonardo
    Ambrosio, Renato
    Gomes, Jose Alvaro Pereira
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (06) : 3505 - 3510
  • [33] Subclinical Keratoconus Detection and Characterization Using Motion-Tracking Brillouin Microscopy
    Randleman, J. Bradley
    Zhang, Hongyuan
    Asroui, Lara
    Tarib, Imane
    Dupps, William J., Jr.
    Scarcelli, Giuliano
    OPHTHALMOLOGY, 2024, 131 (03) : 310 - 321
  • [34] Combining Placido and Corneal Wavefront Data for the Detection of Forme Fruste Keratoconus
    Saad, Alain
    Gatinel, Damien
    JOURNAL OF REFRACTIVE SURGERY, 2016, 32 (08) : 510 - 516
  • [35] Detection of Subclinical Keratoconus by Using Corneal Anterior and Posterior Surface Aberrations and Thickness Spatial Profiles
    Buehren, Jens
    Kook, Daniel
    Yoon, Geunyoung
    Kohnen, Thomas
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (07) : 3424 - 3432
  • [36] Assessment of Corneal Pachymetry Distribution and Morphologic Changes in Subclinical Keratoconus with Normal Biomechanics
    Song, Peng
    Yang, Kaili
    Li, Pei
    Liu, Yu
    Liang, Dengfeng
    Ren, Shengwei
    Zeng, Qingyan
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [37] Correlation Between Corneal Topographic, Densitometry, and Biomechanical Parameters in Keratoconus Eyes
    Shen, Yang
    Han, Tian
    Jhanji, Vishal
    Shang, Jianmin
    Zhao, Jing
    Li, Meiyan
    Zhou, Xingtao
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2019, 8 (03):
  • [38] Corneal Densitometry: Repeatability in Eyes With Keratoconus and Postcollagen Cross-Linking
    Pahuja, Natasha
    Shetty, Rohit
    Subbiah, Priya
    Nagaraja, Harsha
    Nuijts, Rudy M. M. A.
    Jayadev, Chaitra
    CORNEA, 2016, 35 (06) : 833 - 837
  • [39] Corneal Haze and Densitometry in Keratoconus after Collagen Cross-Linking by Three Different Protocols
    Badawi, Amani E.
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2021, 33 (04): : 422 - +
  • [40] Validation of metrics for the detection of subclinical keratoconus in a new patient collective
    Buehren, Jens
    Schaeffeler, Thomas
    Kohnen, Thomas
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (02) : 259 - 268