Detection of Subclinical Keratoconus With a Validated Alternative Method to Corneal Densitometry

被引:10
|
作者
Consejot, Alejandra [1 ,2 ]
Jimenez-Garcia, Marta [3 ,4 ]
Issarti, Ikram [3 ,4 ]
Rozema, Jos J. [3 ,4 ]
机构
[1] Univ Zaragoza, Dept Appl Phys, C Pedro Cerbuna 12, Zaragoza 50009, Spain
[2] Polish Acad Sci, Inst Phys Chem, Warsaw, Poland
[3] Antwerp Univ Hosp, Dept Ophthalmol, Edegem, Belgium
[4] Univ Antwerp, Dept Med & Hlth Sci, Antwerp, Belgium
来源
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY | 2021年 / 10卷 / 09期
关键词
keratoconus; subclinical keratoconus; forme fruste; densitometry; statistical image analysis; DIAGNOSIS; TOMOGRAPHY; ECTASIA; RISK;
D O I
10.1167/tvst.10.9.32
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To enhance the current standards of subclinical keratoconus screening based on the statistical modeling of the pixel intensity distribution of Scheimpflug images. Methods: Scheimpflug corneal tomographies corresponding to 25 corneal meridians of 60 participants were retrospectively collected and divided into three groups: controls (20 eyes), subclinical keratoconus (20 eyes), and clinical keratoconus (20 eyes). Only right eyes were selected. After corneal segmentation, pixel intensities of the stromal tissue were statistically modeled using aWeibull probability density function from which parameter alpha (pixel brightness) was derived. Further, data were transformed to polar coordinates, smoothed, and interpolated to build amap of the corneal alpha parameter. The discriminative power of the method was analyzed using receiver operating characteristic curves. Results: The proposed platform-independent method achieved a higher performance in discriminating subclinical keratoconus from control eyes (90.0% sensitivity, 95.0% specificity, 0.97 area under the curve [AUC]) than the standard method (Belin-Ambrosio enhanced ectasia display), which uses only corneal morphometry (85.0% sensitivity, 85.0% specificity, 0.80 AUC). Conclusions: Analysis of light backscatter at the cornea successfully discriminates subclinical keratoconus from control eyes, upgrading the results previously reported in the literature. Translational Relevance: The proposed methodology has the potential to support clinicians in the detection of keratoconus before showing clinical signs.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Comparison of Discriminant Analysis and Decision Trees for the Detection of Subclinical Keratoconus
    Kleinhans, Sonja
    Herrmann, Eva
    Kohnen, Thomas
    Buehren, Jens
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2019, 236 (06) : 798 - 805
  • [22] Corneal thickness and volume in subclinical and clinical keratoconus
    Seyed Mahdi Ahmadi Hosseini
    Norhani Mohidin
    Fereshteh Abolbashari
    Bariah Mohd-Ali
    Chandramalar T. Santhirathelagan
    International Ophthalmology, 2013, 33 : 139 - 145
  • [23] Corneal thickness and volume in subclinical and clinical keratoconus
    Hosseini, Seyed Mahdi Ahmadi
    Mohidin, Norhani
    Abolbashari, Fereshteh
    Mohd-Ali, Bariah
    Santhirathelagan, Chandramalar T.
    INTERNATIONAL OPHTHALMOLOGY, 2013, 33 (02) : 139 - 145
  • [24] Detection of the early keratoconus based on corneal biomechanical properties in the refractive surgery candidates
    Pniakowska, Zofia
    Jurowski, Piotr
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (02) : 109 - 113
  • [25] Scheimpflug Densitometry in Keratoconus: A New Method of Visualizing the Cone
    Jimenez-Garcia, Marta
    Dhubhghaill, Sorcha Ni
    Consejo, Alejandra
    Hershko, Sarah
    Koppen, Carina
    Rozema, Jos J.
    CORNEA, 2021, 40 (02) : 194 - 202
  • [26] Evaluation of corneal elevation in eyes with subclinical keratoconus and keratoconus using Galilei double Scheimpflug analyzer
    Jafarinasab, Mohammad Reza
    Feizi, Sepehr
    Karimian, Farid
    Hasanpour, Hossein
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2013, 23 (03) : 377 - 384
  • [27] Quantitative assessment of corneal clarity in keratoconus: a case control study of corneal densitometry
    Anayol, Mustafa Alpaslan
    Sekeroglu, Mehmet Ali
    Ceran, Basak Bostanci
    Dogan, Mehmethan
    Gunaydin, Suleyman
    Yilmazbas, Pelin
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2016, 26 (01) : 18 - 23
  • [28] Evaluation of corneal topographic, tomographic and biomechanical indices for detecting clinical and subclinical keratoconus: a comprehensive three-device study
    Heidari, Zahra
    Mohammadpour, Mehrdad
    Amanzadeh, Kazem
    Fotouhi, Akbar
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2021, 14 (02) : 228 - 239
  • [29] Diagnostic Value of Corneal Epithelial and Stromal Thickness Distribution Profiles in Forme Fruste Keratoconus and Subclinical Keratoconus
    Toprak, Ibrahim
    Vega, Alfredo
    Alio del Barrio, Jorge L.
    Espla, Elias
    Cavas, Francisco
    Alio, Jorge L.
    CORNEA, 2021, 40 (01) : 61 - 72
  • [30] Survival Analysis of Corneal Densitometry After Collagen Cross-Linking for Progressive Keratoconus
    Chan, Tommy C. Y.
    Chan, Jason C. K.
    Wang, Yu Meng
    Rapuano, Christopher J.
    CORNEA, 2018, 37 (11) : 1449 - 1456