Statistical analysis of parameters influencing the relationship between outdoor and indoor air quality in schools

被引:100
|
作者
Poupard, O [1 ]
Blondeau, P [1 ]
Iordache, V [1 ]
Allard, F [1 ]
机构
[1] Univ La Rochelle, LEPTAB, F-17042 La Rochelle, France
关键词
schools; principal component analysis; I/O ratios; particulate matter; nitrogen dioxide; nitric oxide; ozone; building permeability;
D O I
10.1016/j.atmosenv.2004.12.016
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Under the French national research program PRIMEQUAL, measurements of outdoor and indoor pollution have been performed in eight school buildings in La Rochelle (France) and its suburbs. The school buildings were either naturally ventilated by opening the windows or mechanically ventilated with minimum fresh air, and demonstrated various permeabilities. Ozone, nitrogen oxides (NO and NO2), and particulate matter (PM) (15 size intervals ranging from 0.3 to 20 mu m) concentrations were monitored continuously indoors and outdoors for two 2-week periods. The indoor relative humidity, temperature, CO2 concentration (room occupancy), window openings and permeability of the building were also measured. Principal component analysis (PCA), a multivariate observation-based statistical method, was used to determine the parameters influencing the relationship between the outdoor and indoor concentration levels. After a brief description of the experimental data and methodology, the paper presents a detailed analysis of the PCA diagrams. This analysis leads to distinguish between positively correlated, negatively correlated and non-correlated variables. The main conclusions arising from the study are: (1) the influence of the room occupancy on the particle concentrations indoors changes with different particle sizes, (2) the building air-tightness and the outdoor concentration level greatly influence the indoor/outdoor (I/O) concentration ratios of ozone, and (3) indoor ozone and particles concentrations are negatively correlated, which may be the result of complex homogeneous and/or heterogeneous processes. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2071 / 2080
页数:10
相关论文
共 50 条
  • [41] A review of relevant parameters for assessing indoor air quality in educational facilities
    Branco, Pedro T. B. S.
    Sousa, Sofia I. V.
    Dudzinska, Marzenna R.
    Ruzgar, Duygu Gazioglu
    Mutlu, Mustafa
    Panaras, Georgios
    Papadopoulos, Giannis
    Saffell, John
    Scutaru, Ana Maria
    Struck, Christian
    Weersink, Annemarie
    ENVIRONMENTAL RESEARCH, 2024, 261
  • [42] Indoor Air Quality in Schools Located in Poland, Lublin Province
    Dumala, Slawomira Maria
    Guz, Lukasz
    Badora, Anna
    JOURNAL OF ECOLOGICAL ENGINEERING, 2024, 25 (01): : 17 - 26
  • [43] Characterization of indoor air quality in primary schools in Antwerp, Belgium
    Stranger, M.
    Potgieter-Vermaak, S. S.
    Van Grieken, R.
    INDOOR AIR, 2008, 18 (06) : 454 - 463
  • [44] Can changing the timing of outdoor air intake reduce indoor concentrations of traffic-related pollutants in schools?
    MacNeill, M.
    Dobbin, N.
    St-Jean, M.
    Wallace, L.
    Marro, L.
    Shin, T.
    You, H.
    Kulka, R.
    Allen, R. W.
    Wheeler, A. J.
    INDOOR AIR, 2016, 26 (05) : 687 - 701
  • [45] The relationship between indoor and outdoor levels of PM10 and its chemical composition at schools in a coastal region in Spain
    Pallares, Susana
    Gomez, EvaTrinidad
    Martinez, Africa
    Miguel Jordan, Manuel
    HELIYON, 2019, 5 (08)
  • [46] The relationship between outdoor air pollutants and atopic dermatitis of adults: A systematic review and meta-analysis
    Hsiao, Yu -Yu
    Chen, Yi-Hsing
    Hung, Wei-Ting
    Tang, Kuo-Tung
    ASIAN PACIFIC JOURNAL OF ALLERGY AND IMMUNOLOGY, 2022, 40 (04): : 295 - 307
  • [47] Statistical correlation analysis on indoor air high-priority pollutants in Spanish public primary schools
    Calama-Gonzalez, Carmen Maria
    Redondas, Dolores
    Sabariego-Moreno, Kevin
    Barbero-Barrera, Maria del Mar
    JOURNAL OF BUILDING ENGINEERING, 2025, 101
  • [48] Analysis on Indoor Air Quality of School
    He, Wen-hao
    Wang, Hai-juan
    Xie, Chao-yang
    Wang, Cui-cui
    Gao, Hua-ping
    2016 INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND ENGINEERING (ESE 2016), 2016, : 936 - 941
  • [49] Indoor/outdoor relationship of PM2.5 concentration in typical buildings with and without air cleaning in Beijing
    Deng, Gaofeng
    Li, Zenghe
    Wang, Zhichao
    Gao, Jubao
    Xu, Zhaowei
    Li, Jiandong
    Wang, Zhiyong
    INDOOR AND BUILT ENVIRONMENT, 2017, 26 (01) : 60 - 68
  • [50] Machine learning and statistical models for predicting indoor air quality
    Wei, Wenjuan
    Ramalho, Olivier
    Malingre, Laeticia
    Sivanantham, Sutharsini
    Little, John C.
    Mandin, Corinne
    INDOOR AIR, 2019, 29 (05) : 704 - 726