The effect of vessel material properties and pulsatile wall motion on the fixation of a proximal stent of an endovascular graft

被引:12
作者
Corbett, T. J. [1 ]
Molony, D. S. [1 ]
Callanan, A. [1 ]
McGloughlin, T. M. [1 ]
机构
[1] Univ Limerick, MSSi, Dept Mech & Aeronaut Engn, CABER, Limerick, Ireland
关键词
Abdominal aortic aneurysm (AAA); Stent-graft migration; Artery analogue; Proximal stent attachment force; ABDOMINAL AORTIC-ANEURYSMS; IN-VIVO; ILIAC FIXATION; MIGRATION; REPAIR; MODEL; DISPLACEMENT; RESISTANCE; AAA;
D O I
10.1016/j.medengphy.2010.09.013
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Migration is a serious failure mechanism associated with endovascular abdominal aortic aneurysm (AAA) repair (EVAR). The effect of vessel material properties and pulsatile wall motion on stent fixation has not been previously investigated. A proximal stent from a commercially available stent graft was implanted into the proximal neck of silicone rubber abdominal aortic aneurysm models of varying proximal neck stiffness (beta = 25.39 and 20.44). The stent was then dislodged by placing distal force on the stent struts. The peak force to completely dislodge the stent was measured using a loadcell. Dislodgment was performed at ambient pressure with no flow (NF) and during pulsatile flow (PF) at pressures of 120/80 mmHg and 140/100 mmHg to determine if pulsatile wall motions affected the dislodgement force. An imaging analysis was performed at ambient pressure and at pressures of 120 mmHg and 140 mmHg to investigate diameter changes on the model due to the radial force of the stent and internal pressurisation. Stent displacement forces were similar to 50% higher in the stiffer model (7.16-8.4 N) than in the more compliant model (3.67-4.21 N). The mean displacement force was significantly reduced by 10.95-12.83% from the case of NF to the case of PF at 120/80 mmHg. A further increase in pressure to 140/120 mmHg had no significant effect on the displacement force. The imaging analysis showed that the diameter in the region of the stent was 0.37 mm greater in the less stiff model at all the pressures which could reduce the fixation of the stent. The results suggest that the fixation of passively fixated aortic stents could be comprised in more compliant walls and that pulsatile motions of the wall can reduce the maximum stent fixation. (C) 2010 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:106 / 111
页数:6
相关论文
共 38 条
[1]  
*AM HEART ASS, 2002, HEART DIS STROK STAT
[2]   Iliac fixation length and resistance to in-vivo stent-graft displacement [J].
Arko, FR ;
Heikkinen, M ;
Lee, ES ;
Bass, A ;
Alsac, JM ;
Zarins, CK .
JOURNAL OF VASCULAR SURGERY, 2005, 41 (04) :664-670
[3]  
BROWN R, 2006, PHYS TESTING RUBBERS, P218
[4]   Device migration after endoluminal abdominal aortic aneurysm repair: Analysis of 113 cases with a minimum follow-up period of 2 years [J].
Cao, P ;
Verzini, F ;
Zannetti, S ;
De Rango, P ;
Parlani, G ;
Lupattelli, L ;
Maselli, A .
JOURNAL OF VASCULAR SURGERY, 2002, 35 (02) :229-235
[5]   Engineering Silicone Rubbers for In Vitro Studies: Creating AAA Models and ILT Analogues With Physiological Properties [J].
Corbett, T. J. ;
Doyle, B. J. ;
Callanan, A. ;
Walsh, M. T. ;
McGloughlin, T. M. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2010, 132 (01)
[6]   A Review of the In Vivo and In Vitro Biomechanical Behavior and Performance of Postoperative Abdominal Aortic Aneurysms and Implanted Stent-Grafts [J].
Corbett, Timothy J. ;
Callanan, Anthony ;
Morris, Liam G. ;
Doyle, Barry J. ;
Grace, Pierce A. ;
Kavanagh, Eamon G. ;
McGloughlin, Tim M. .
JOURNAL OF ENDOVASCULAR THERAPY, 2008, 15 (04) :468-484
[7]  
CORBETT TJ, 2009, INT UN PHYS ENG SCI
[8]   THE INFLUENCE OF LOAD AND SURFACE ROUGHNESS ON THE FRICTION OF RUBBER-LIKE MATERIALS [J].
DENNY, DF .
PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON SECTION B, 1953, 66 (405) :721-727
[9]   3D reconstruction and manufacture of real abdominal aortic aneurysms: From CT scan to silicone model [J].
Doyle, B. J. ;
Morris, L. G. ;
Callanan, A. ;
Kelly, P. ;
Vorp, D. A. ;
McGloughlin, T. M. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (03)
[10]   Experimental modelling of aortic aneurysms: Novel applications of silicone rubbers [J].
Doyle, Barry J. ;
Corbett, Timothy J. ;
Cloonan, Aidan J. ;
O'Donnell, Michael R. ;
Walsh, Michael T. ;
Vorp, David A. ;
McGloughlin, Timothy M. .
MEDICAL ENGINEERING & PHYSICS, 2009, 31 (08) :1002-1012