Role of stationary phase and eluent composition on the determination of log P values of N-hydroxyethylamide of aryloxyalkylen- and pyridine carboxylic acids by reversed-phase high-performance liquid chromatography

被引:30
|
作者
Cimpan, G
Irimie, F
Gocan, S
Claessens, HA
机构
[1] Eindhoven Univ Technol, Dept Chem Engn, Instrumental Anal Lab, NL-5600 Eindhoven, Netherlands
[2] Univ Babes Bolyai, Fac Chem & Chem Engn, Dept Analyt Chem, R-3400 Cluj Napoca, Romania
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 1998年 / 714卷 / 02期
关键词
stationary phases; LC; mobile phases; N-hydroxyethylamide; aryloxyalkylen carboxylic acid; pyridine carboxylic acid;
D O I
10.1016/S0378-4347(98)00228-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The partition coefficients, P, between n-octanol and water of a number of growth stimulating substances, N-hydroxyethylamide of aryloxyalkylen- and pyridine carboxylic acids were obtained from Pomona College (Clog P), and Rekker's (log P-Rekker) revised fragmental constant system was used to calculate log P data sets. Both of these data sets were correlated with two different substance lipophilicity parameters, log k(w) and phi(o). Log k(w) was obtained by extrapolation of log retention factor (k) to 0% organic modifier measured in reversed-phase liquid chromatography (RPLC) systems. phi(o) values were obtained from the slopes and intercepts of these relationships. The RPLC experiments were performed on four commercially available reversed-phase columns. Binary mixtures of methanol-water, methanol-phosphate buffer (pH 7.0), methanol-tricine buffer (pH 7.0) and acetonitrile-water were used as mobile phases for the determination of log k(w) values. For the methanolic eluents linear regression provided satisfactory correlations (r>0.99) for the relationships log k vs, organic modifier content in the eluent, while for the acetonitrile-containing eluents a second-degree polynominal regression was necessary. For all four RPLC columns, by linear regression satisfactory correlations (r>0.99) were obtained between log k(w) and log P data using methanolic eluents. In such eluents phi(o) values were shown to be the second-best lipophilicity parameters. For acetonitrile-containing eluents the use of second-degree polynominal regression was necessary and, in contrast to methanol, significant influence of the applied column on regression results was observed. For acetonitrile-containing eluents the phi(o)-index does not provide satisfactory results for our substances. No difference in regression results between the use of buffered and non-buffered eluents was observed. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:247 / 261
页数:15
相关论文
共 34 条
  • [21] Impact of the post-treatment conditions of parent silica on the silanization of n-octadecyl bonded silica packings in reversed-phase high-performance liquid chromatography
    Grossmann, F
    Ehwald, V
    von Hohenesche, CD
    Unger, KK
    JOURNAL OF CHROMATOGRAPHY A, 2001, 910 (02) : 223 - 236
  • [22] Determination of the retention behavior of barbituric acid derivatives in reversed-phase high-performance liquid chromatography by using quantitative structure-retention relationships
    Jakab, A
    Schubert, G
    Prodan, M
    Forgács, E
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 770 (1-2): : 227 - 236
  • [23] Laterally attached liquid-crystalline polymers as stationary phases in reversed-phase high-performance liquid chromatography III.: Effect of the local anisotropic order on the separation of polycyclic aromatic hydrocarbons
    Gritti, F
    Félix, G
    Achard, MF
    Hardouin, F
    JOURNAL OF CHROMATOGRAPHY A, 2001, 913 (1-2) : 147 - 157
  • [24] Determination of amino acids in the foods by reversed-phase high-performance liquid chromatography with a new precolumn derivative, butylthiocarbamyl amino acid, compared to the conventional phenylthiocarbamyl derivatives and ion-exchange chromatography
    Woo, KL
    Hwang, QC
    Kim, HS
    JOURNAL OF CHROMATOGRAPHY A, 1996, 740 (01) : 31 - 40
  • [25] Determination of gentamicin in urine samples after inhalation by reversed-phase high-performance liquid chromatography using pre-column derivatisation with o-phthalaldehyde
    Al-Amoud, AI
    Clark, BJ
    Chrystyn, H
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 769 (01): : 89 - 95
  • [26] Determination of 1-deoxynojirimycin in Morus alba L. leaves by derivatization with 9-fluorenylmethyl chloroformate followed by reversed-phase high-performance liquid chromatography
    Kim, JW
    Kim, SU
    Lee, HS
    Kim, I
    Ahn, MY
    Ryu, KS
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1002 (1-2) : 93 - 99
  • [27] Determination of 9-nitrocamptothecin by precolumn derivatization and its metabolite 9-aminocamptothecin in a biological fluid using reversed-phase high-performance liquid chromatography with fluorescence detection
    Zhang, JH
    Burke, TG
    Latus, LJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 795 (02): : 309 - 318
  • [28] Separation of enantiomers of chiral weak acids with polysaccharide-based chiral columns and aqueous-organic mobile phases in high-performance liquid chromatography: Typical reversed-phase behavior?
    Matarashvili, Iza
    Ghughunishvili, Darejan
    Chankvetadze, Lali
    Takaishvili, Nino
    Khatiashvili, Tamar
    Tsintsadze, Maia
    Farkas, Tivadar
    Chankvetadze, Bezhan
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1483 : 86 - 92
  • [29] Determination of Ro 48-3656 in rat plasma by reversed-phase high-performance liquid chromatography -: Comparison of 1.5-μm nonporous silica to 3.5-μm porous silica analytical columns
    Paasch, BD
    Lin, YS
    Porter, S
    Modi, NB
    Barder, TJ
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 704 (1-2): : 231 - 242
  • [30] Simultaneous determination of dopamine and 3,4-dihydroxyphenylacetic acid in mouse striatum using mixed-mode reversed-phase and cation-exchange high-performance liquid chromatography
    Tsunoda, Makoto
    Aoyama, Chiaki
    Nomura, Hiroshi
    Toyoda, Takeshi
    Matsuki, Norio
    Funatsu, Takashi
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2010, 51 (03) : 712 - 715