Intrascanner and Interscanner Variability of Magnetization Transfer-Sensitized Balanced Steady-State Free Precession Imaging

被引:10
|
作者
Gloor, M. [1 ]
Scheffler, K. [1 ]
Bieri, O. [1 ]
机构
[1] Univ Basel Hosp, Dept Med Radiol, Div Radiol Phys, CH-4031 Basel, Switzerland
基金
瑞士国家科学基金会;
关键词
magnetization transfer imaging; magnetization transfer ratio; MTR; steady-state free precession; balanced SSFP; TRANSFER RATIO; WHITE-MATTER; MULTIPLE-SCLEROSIS; TISSUE; RELAXATION; SEQUENCE; SSFP; T-1;
D O I
10.1002/mrm.22694
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, a new and fast three-dimensional imaging technique for magnetization transfer ratio (MTR) imaging has been proposed based on a balanced steady-state free precession protocol with modified radiofrequency pulses. In this study, optimal balanced steady-state free precession MTR protocol parameters were derived for maximum stability and reproducibility. Variability between scans was assessed within white and gray matter for nine healthy volunteers using two different 1.5 T clinical systems at six different sites. Intrascanner and interscanner MTR measurements were well reproducible (coefficient of variation: c(v) < 0.012 and c(v) < 0.015, respectively) and results indicate a high stability across sites (c(v) < 0.017) for optimal flip angle settings. This study demonstrates that balanced steady-state free precession MTR not only benefits from short acquisition time and high signal-to-noise ratio but also offers excellent reproducibility and low variability, and it is thus proposed for clinical MTR scans at individual sites as well as for multicenter studies. Magn Reson Med 65:1113-1118, 2011. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1113 / 1118
页数:6
相关论文
共 50 条
  • [41] Whole-brain perfusion imaging with balanced steady-state free precession arterial spin labeling
    Han, Paul Kyu
    Ye, Jong Chul
    Kim, Eung Yeop
    Choi, Seung Hong
    Park, Sung-Hong
    NMR IN BIOMEDICINE, 2016, 29 (03) : 264 - 274
  • [42] Morphing steady-state free precession
    Bieri, O.
    Patil, S.
    Quick, H. H.
    Scheffler, K.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (06) : 1242 - 1248
  • [43] Balanced Steady State Free Precession fMRI
    Lee, Jin Hyung
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2010, 20 (01) : 23 - 30
  • [44] Effect of diffusion in inhomogeneous magnetic fields on balanced steady-state free precession
    Bieri, O.
    Scheffler, K.
    NMR IN BIOMEDICINE, 2007, 20 (01) : 1 - 10
  • [45] Balanced steady-state free precession fMRI with intravascular susceptibility contrast agent
    Zhou, Iris Y.
    Cheung, Matthew M.
    Lau, Condon
    Chan, Kevin C.
    Wu, Ed X.
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 65 - 73
  • [46] Use of Balanced Steady-State Free Precession Sequences in Evaluation of Drop Metastases
    Vossough, A.
    Melhem, E. R.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (05) : E20 - E20
  • [47] Monitoring and Compensating Phase Imperfections in Cine Balanced Steady-State Free Precession
    Fischer, Rudolf Fritz
    Barmet, Christoph
    Rudin, Markus
    Boesiger, Peter
    Pruessmann, Klaas Paul
    Kozerke, Sebastian
    MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (06) : 1567 - 1579
  • [48] Spin-Locked Balanced Steady-State Free-Precession (slSSFP)
    Witschey, Walter R. T.
    Borthakur, Ari
    Elliott, Mark A.
    Magland, Jeremy
    McArdle, Erin L.
    Wheaton, Andrew
    Reddy, Ravinder
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) : 993 - 1001
  • [50] Balanced steady-state free precession with parallel imaging gives distortion-free fMRI with high temporal resolution
    Chappell, Michael
    Haberg, Asta K.
    Kristoffersen, Anders
    MAGNETIC RESONANCE IMAGING, 2011, 29 (01) : 1 - 8