Intrascanner and Interscanner Variability of Magnetization Transfer-Sensitized Balanced Steady-State Free Precession Imaging

被引:10
|
作者
Gloor, M. [1 ]
Scheffler, K. [1 ]
Bieri, O. [1 ]
机构
[1] Univ Basel Hosp, Dept Med Radiol, Div Radiol Phys, CH-4031 Basel, Switzerland
基金
瑞士国家科学基金会;
关键词
magnetization transfer imaging; magnetization transfer ratio; MTR; steady-state free precession; balanced SSFP; TRANSFER RATIO; WHITE-MATTER; MULTIPLE-SCLEROSIS; TISSUE; RELAXATION; SEQUENCE; SSFP; T-1;
D O I
10.1002/mrm.22694
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, a new and fast three-dimensional imaging technique for magnetization transfer ratio (MTR) imaging has been proposed based on a balanced steady-state free precession protocol with modified radiofrequency pulses. In this study, optimal balanced steady-state free precession MTR protocol parameters were derived for maximum stability and reproducibility. Variability between scans was assessed within white and gray matter for nine healthy volunteers using two different 1.5 T clinical systems at six different sites. Intrascanner and interscanner MTR measurements were well reproducible (coefficient of variation: c(v) < 0.012 and c(v) < 0.015, respectively) and results indicate a high stability across sites (c(v) < 0.017) for optimal flip angle settings. This study demonstrates that balanced steady-state free precession MTR not only benefits from short acquisition time and high signal-to-noise ratio but also offers excellent reproducibility and low variability, and it is thus proposed for clinical MTR scans at individual sites as well as for multicenter studies. Magn Reson Med 65:1113-1118, 2011. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1113 / 1118
页数:6
相关论文
共 50 条
  • [31] Frequency-modulated steady-state free precession imaging
    Foxall, DL
    MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (03) : 502 - 508
  • [32] STEADY-STATE FREE PRECESSION IMAGING OF THE INNER-EAR
    STILLMAN, AE
    REMLEY, K
    LOES, DJ
    HU, XP
    LATCHAW, RE
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1994, 15 (02) : 348 - 350
  • [33] RAPID FOURIER-IMAGING WITH STEADY-STATE FREE PRECESSION
    PATZ, S
    HAWKES, RC
    INVESTIGATIVE RADIOLOGY, 1986, 21 (09) : S35 - S35
  • [34] THE DIFFUSION SENSITIVITY OF FAST STEADY-STATE FREE PRECESSION IMAGING
    BUXTON, RB
    MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (02) : 235 - 243
  • [35] Arterial spin labeled perfusion imaging with balanced steady-state free precession readout and radial sampling
    Han, Paul Kyu
    Marin, Thibault
    Zhuo, Yue
    Ouyang, Jinsong
    El Fakhri, Georges
    Ma, Chao
    MAGNETIC RESONANCE IMAGING, 2023, 102 : 126 - 132
  • [36] Resting-State fMRI Using Passband Balanced Steady-State Free Precession
    Cheng, Joe S.
    Gao, Patrick P.
    Zhou, Iris Y.
    Chan, Russell W.
    Chan, Queenie
    Mak, Henry K.
    Khong, Pek L.
    Wu, Ed X.
    PLOS ONE, 2014, 9 (03):
  • [37] Profile-encoding reconstruction for multiple-acquisition balanced steady-state free precession imaging
    Ilicak, Efe
    Senel, Lutfi Kerem
    Biyik, Erdem
    Cukur, Tolga
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (04) : 1316 - 1329
  • [38] 6 Improved dark blood imaging of the heart using radial balanced steady-state free precession
    Edelman, Robert R.
    Botelho, Marcos
    Pursnani, Amit
    Giri, Shivraman
    Koktzoglou, Ioannis
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
  • [39] Use of simulated annealing for the design of multiple repetition time balanced steady-state free precession imaging
    Lee, Kuan J.
    Lee, Hsu-Lei
    Hennig, Juergen
    Leupold, Jochen
    MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (01) : 220 - 226
  • [40] Off-resonance-dependent slice profile effects in balanced steady-state free precession imaging
    Staehle, F.
    Leupold, J.
    Hennig, J.
    Markl, M.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (05) : 1197 - 1202