Intrascanner and Interscanner Variability of Magnetization Transfer-Sensitized Balanced Steady-State Free Precession Imaging

被引:10
作者
Gloor, M. [1 ]
Scheffler, K. [1 ]
Bieri, O. [1 ]
机构
[1] Univ Basel Hosp, Dept Med Radiol, Div Radiol Phys, CH-4031 Basel, Switzerland
基金
瑞士国家科学基金会;
关键词
magnetization transfer imaging; magnetization transfer ratio; MTR; steady-state free precession; balanced SSFP; TRANSFER RATIO; WHITE-MATTER; MULTIPLE-SCLEROSIS; TISSUE; RELAXATION; SEQUENCE; SSFP; T-1;
D O I
10.1002/mrm.22694
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, a new and fast three-dimensional imaging technique for magnetization transfer ratio (MTR) imaging has been proposed based on a balanced steady-state free precession protocol with modified radiofrequency pulses. In this study, optimal balanced steady-state free precession MTR protocol parameters were derived for maximum stability and reproducibility. Variability between scans was assessed within white and gray matter for nine healthy volunteers using two different 1.5 T clinical systems at six different sites. Intrascanner and interscanner MTR measurements were well reproducible (coefficient of variation: c(v) < 0.012 and c(v) < 0.015, respectively) and results indicate a high stability across sites (c(v) < 0.017) for optimal flip angle settings. This study demonstrates that balanced steady-state free precession MTR not only benefits from short acquisition time and high signal-to-noise ratio but also offers excellent reproducibility and low variability, and it is thus proposed for clinical MTR scans at individual sites as well as for multicenter studies. Magn Reson Med 65:1113-1118, 2011. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1113 / 1118
页数:6
相关论文
共 50 条
  • [31] Effect of diffusion in inhomogeneous magnetic fields on balanced steady-state free precession
    Bieri, O.
    Scheffler, K.
    NMR IN BIOMEDICINE, 2007, 20 (01) : 1 - 10
  • [32] Spin-Locked Balanced Steady-State Free-Precession (slSSFP)
    Witschey, Walter R. T.
    Borthakur, Ari
    Elliott, Mark A.
    Magland, Jeremy
    McArdle, Erin L.
    Wheaton, Andrew
    Reddy, Ravinder
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (04) : 993 - 1001
  • [33] Whole Heart Magnetization-Prepared Steady-State Free Precession Coronary Vein MRI
    Stoeck, Christian T.
    Han, Yuchi
    Peters, Dana C.
    Hu, Peng
    Yeon, Susan B.
    Kissinger, Kraig V.
    Goddu, Beth
    Goepfert, Lois
    Manning, Warren J.
    Kozerke, Sebastian
    Nezafat, Reza
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (06) : 1293 - 1299
  • [34] Investigating exchange and multicomponent relaxation in fully-balanced steady-state free precession imagaing
    Deoni, Sean C. L.
    Rutt, Brian K.
    Jones, Derek K.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (06) : 1421 - 1429
  • [35] Balanced steady-state free precession with parallel imaging gives distortion-free fMRI with high temporal resolution
    Chappell, Michael
    Haberg, Asta K.
    Kristoffersen, Anders
    MAGNETIC RESONANCE IMAGING, 2011, 29 (01) : 1 - 8
  • [36] Linear combination steady-state free precession MRI
    Vasanawala, SS
    Pauly, JM
    Nishimura, DG
    MAGNETIC RESONANCE IN MEDICINE, 2000, 43 (01) : 82 - 90
  • [37] Magnetic resonance imaging of knee cartilage using a water selective balanced steady-state free precession sequence
    Kornaat, PR
    Doornbos, J
    van der Molen, AJ
    Kloppenburg, M
    Nelissen, RG
    Hogendoorn, PCW
    Bloem, JL
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (05) : 850 - 856
  • [38] On flow effects in balanced steady-state free precession imaging: Pictorial description, parameter dependence, and clinical implications
    Markl, M
    Pelc, NJ
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (04) : 697 - 705
  • [39] Influence of MT Effects on T2 Quantification with 3D Balanced Steady-State Free Precession Imaging
    Crooijmans, Hendrikus J. A.
    Gloor, Monika
    Bieri, Oliver
    Scheffler, Klaus
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (01) : 195 - 201
  • [40] Fat and water separation in balanced steady-state free precession using the Dixon method
    Huang, TY
    Chung, HW
    Wang, FN
    Ko, CW
    Chen, CY
    MAGNETIC RESONANCE IN MEDICINE, 2004, 51 (02) : 243 - 247