Intrascanner and Interscanner Variability of Magnetization Transfer-Sensitized Balanced Steady-State Free Precession Imaging

被引:10
|
作者
Gloor, M. [1 ]
Scheffler, K. [1 ]
Bieri, O. [1 ]
机构
[1] Univ Basel Hosp, Dept Med Radiol, Div Radiol Phys, CH-4031 Basel, Switzerland
基金
瑞士国家科学基金会;
关键词
magnetization transfer imaging; magnetization transfer ratio; MTR; steady-state free precession; balanced SSFP; TRANSFER RATIO; WHITE-MATTER; MULTIPLE-SCLEROSIS; TISSUE; RELAXATION; SEQUENCE; SSFP; T-1;
D O I
10.1002/mrm.22694
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, a new and fast three-dimensional imaging technique for magnetization transfer ratio (MTR) imaging has been proposed based on a balanced steady-state free precession protocol with modified radiofrequency pulses. In this study, optimal balanced steady-state free precession MTR protocol parameters were derived for maximum stability and reproducibility. Variability between scans was assessed within white and gray matter for nine healthy volunteers using two different 1.5 T clinical systems at six different sites. Intrascanner and interscanner MTR measurements were well reproducible (coefficient of variation: c(v) < 0.012 and c(v) < 0.015, respectively) and results indicate a high stability across sites (c(v) < 0.017) for optimal flip angle settings. This study demonstrates that balanced steady-state free precession MTR not only benefits from short acquisition time and high signal-to-noise ratio but also offers excellent reproducibility and low variability, and it is thus proposed for clinical MTR scans at individual sites as well as for multicenter studies. Magn Reson Med 65:1113-1118, 2011. (C) 2010 Wiley-Liss, Inc.
引用
收藏
页码:1113 / 1118
页数:6
相关论文
共 50 条
  • [1] Optimized balanced steady-state free precession magnetization transfer Imaging
    Bieri, O.
    Scheffler, K.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 58 (03) : 511 - 518
  • [2] Steady State Free Precession Magnetization Transfer Imaging
    Bieri, Oliver
    Mamisch, Tallas C.
    Trattnig, Siegfried
    Scheffler, Klaus
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (05) : 1261 - 1266
  • [3] Spiral balanced steady-state free precession cardiac imaging
    Nayak, KS
    Hargreaves, BA
    Hu, BS
    Nishimura, DG
    Pauly, JM
    Meyer, CH
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1468 - 1473
  • [4] Magnetization evolution in balanced steady-state free precession with continuously moving table
    Stafford, Randall B.
    Sabati, Mohammad
    Mahallati, Houman
    Frayne, Richard
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (08): : N173 - N184
  • [5] Unbiased signal equation for quantitative magnetization transfer mapping in balanced steady-state free precession MRI
    Bayer, Fritz M.
    Bock, Michael
    Jezzard, Peter
    Smith, Alex K.
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (01) : 446 - 456
  • [6] Pure balanced steady-state free precession imaging (pure bSSFP)
    Schaeper, Jessica
    Bauman, Grzegorz
    Ganter, Carl
    Bieri, Oliver
    MAGNETIC RESONANCE IN MEDICINE, 2022, 87 (04) : 1886 - 1893
  • [7] Multiple Repetition Time Balanced Steady-State Free Precession Imaging
    Cukur, Tolga
    Nishimura, Dwight G.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (01) : 193 - 204
  • [8] Imaging periodic currents using alternating balanced steady-state free precession
    Buracas, Giedrius T.
    Liu, Thomas T.
    Buxton, Richard B.
    Frank, Lawrence R.
    Wong, Eric C.
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (01) : 140 - 148
  • [9] Spectrally selective imaging with wideband balanced steady-state free precession MRI
    Cukur, Tolga
    MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (03) : 1132 - 1141
  • [10] Intrinsic fat suppression in TIDE balanced steady-state free precession imaging
    Paul, Dominik
    Hennig, Juergen
    Zaitsev, Maxim
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) : 1328 - 1335