Fast modelling of the collimator-detector response in Monte Carlo simulation of SPECT imaging using the angular response function

被引:62
作者
Song, X [1 ]
Segars, WP [1 ]
Du, Y [1 ]
Tsui, BMW [1 ]
Frey, EC [1 ]
机构
[1] Johns Hopkins Univ, Dept Radiol & Radiol Sci, Baltimore, MD 21218 USA
关键词
D O I
10.1088/0031-9155/50/8/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Interactions of incident photons with the collimator and detector, including septal penetration, scatter and x-ray fluorescence, are significant sources of image degradation in applications of SPECT including dual isotope imaging and imaging using radioisotopes that emit high- or medium-energy photons. Modelling these interactions using full Monte Carlo (MC) simulations is computationally very demanding. We present a new method based on the use of angular response functions (ARFs). The ARF is a function of the incident photon's direction and energy and represents the probability that a photon will either interact with or pass through the collimator, and be detected at the intersection of the photon's direction vector and the detection plane in an energy window of interest. The ARFs were pre-computed using full MC simulations of point sources that include propagation through the collimator-detector system. We have implemented the ARF method for use in conjunction with the SimSET/PHG MC code to provide fast modelling of both interactions in the patient and in the collimator-detector system. Validation results in the three cases studied show that there was good agreement between the projections generated using the ARF method and those from previously validated full MC simulations, but with hundred to thousand fold reductions in simulation time.
引用
收藏
页码:1791 / 1804
页数:14
相关论文
共 31 条
[1]  
BECK JW, 1982, IEEE T NUCL SCI, V29, P506, DOI 10.1109/TNS.1982.4335896
[2]  
De Jong HW, 2001, J NUCL MED, V42, p193P
[3]   DEVELOPMENT AND VALIDATION OF A MONTE-CARLO SIMULATION OF PHOTON TRANSPORT IN AN ANGER CAMERA [J].
DEVRIES, DJ ;
MOORE, SC ;
ZIMMERMAN, RE ;
MUELLER, SP ;
FRIEDLAND, B ;
LANZA, RC .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1990, 9 (04) :430-438
[4]  
DEVRIES DJ, 1994, J NUCL MED, V35, pP192
[5]   Monte Carlo evaluation of object shape effects in iodine-1 31 SPET tumor activity quantification [J].
Dewaraja, YK ;
Ljungberg, M ;
Koral, KF .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 2001, 28 (07) :900-906
[6]   Combination of MCNP and SimSET for Monte Carlo simulation of SPECT with medium- and high-energy photons [J].
Du, Y ;
Frey, EC ;
Wang, WT ;
Tocharoenchai, C ;
Baird, WH ;
Tsui, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (03) :668-674
[7]   MONTE-CARLO EVALUATION OF COMPTON SCATTER SUBTRACTION IN SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY [J].
FLOYD, CE ;
JASZCZAK, RJ ;
HARRIS, CC ;
GREER, KL ;
COLEMAN, RE .
MEDICAL PHYSICS, 1985, 12 (06) :776-778
[8]   Geometrical response of multihole collimators [J].
Formiconi, AR .
PHYSICS IN MEDICINE AND BIOLOGY, 1998, 43 (11) :3359-3379
[9]   PARAMETERIZATION OF THE SCATTER RESPONSE FUNCTION IN SPECT IMAGING USING MONTE-CARLO SIMULATION [J].
FREY, EC ;
TSUI, BMW .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1990, 37 (03) :1308-1315
[10]   Application of task-based measures of image quality to optimization and evaluation of three-dimensional reconstruction-based compensation methods in myocardial perfusion SPECT [J].
Frey, EC ;
Gilland, KL ;
Tsui, BMW .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) :1040-1050