Highly selective and sensitive reversible sensor for Cu (II) detection based on hollow TiO2 spheres modified by fluorescein hydrozine-3,6-diacetic acid

被引:18
作者
Kang, Mengmeng [1 ]
Wang, Minghua [1 ,2 ]
Zhang, Shuai [1 ]
Dong, Xiaodong [1 ]
He, Linghao [1 ]
Zhang, Yonghui [1 ]
Guo, Dongjie [1 ]
Wang, Peiyuan [1 ]
Fang, Shaoming [1 ,2 ]
Zhang, Zhihong [1 ,2 ]
机构
[1] Zhengzhou Univ Light Ind, State Lab Surface & Interface Sci Henan Prov, Zhengzhou 450001, Peoples R China
[2] Zhengzhou Univ Light Ind, Henan Collaborat Innovat Ctr Environm Pollut Cont, Zhengzhou 450001, Peoples R China
基金
中国国家自然科学基金;
关键词
Fluorescein hydrozine; Cu(II) detection; Hollow TiO2 spheres; Electrochemical sensor; ELECTRODE MATERIAL; IMPEDANCE SPECTROSCOPY; AQUEOUS-SOLUTION; GLUCOSE-OXIDASE; ON FLUORESCENT; MECHANISM; HG2+; NANOPARTICLES; MICROSPHERES; BIOSENSOR;
D O I
10.1016/j.electacta.2015.02.094
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We report a novel electrochemical sensor for the sensitive detection of Cu(II) ions based on hollow TiO2 spheres modified by fluorescein hydrozine-3,6-diacetic acid (FH). Herein, hollow TiO2 spheres were synthesized via the hydrothermal method with the carbon spheres as the template then modified by (3-aminopropyl) trimethoxysilane (APTMS) to form the amino group-modified TiO2 spheres (TiO2-APTMS). Simultaneously, FH was activated by 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride/N-hydroxysuccinimide, in which the carboxyl groups were changed to active ester groups. Consequently, TiO2-APTMS spheres could be modified by FH with the activated ester groups via the bonding of amide groups to produce the composite electrode with TiO2 and FH (Au-TiO2-FH). The resulting Au-TiO2-FH was used to develop the electrochemical sensor for the highly sensitive detection of Cu2+ in aqueous solution because of the coordination between Cu2+ and FH, the whole process of which was determined via electrochemical impedance spectroscopy. The results showed that a detection limit of 4.29 pM of the developed sensor within the range from 5 pM to 1mM was obtained. Furthermore, the interference from other metal ions, such as K+, Na+, Ag+, Ni2+, Mn2+, Zn2+, Mg2+, and Fe3+, associated with Cu2+ analysis could be effectively inhibited. Most importantly, the developed electrochemical sensor could be reproduced and degraded by UV light irradiation because of the light degradation ability of TiO2 toward FH. This novel sensor could also be used to detect other heavy metal ions when TiO2 spheres are modified by the relative FH. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:186 / 194
页数:9
相关论文
共 61 条
  • [1] Gold electrode modified with a self-assembled glucose oxidase and 2,6-pyridinedicarboxylic acid as novel glucose bioanode for biofuel cells
    Ammam, Malika
    Fransaer, Jan
    [J]. JOURNAL OF POWER SOURCES, 2014, 257 : 272 - 279
  • [2] Synthesis and applications of Rhodamine derivatives as fluorescent probes
    Beija, Mariana
    Afonso, Carlos A. M.
    Martinho, Jose M. G.
    [J]. CHEMICAL SOCIETY REVIEWS, 2009, 38 (08) : 2410 - 2433
  • [3] Control of the size and shape of TiO2 nanoparticles in restricted media
    Biswas, Abhijit
    Corani, Alice
    Kathiravan, Arunkumar
    Infahsaeng, Yingyot
    Yartsev, Arkady
    Sundstrom, Villy
    De, Swati
    [J]. NANOTECHNOLOGY, 2013, 24 (19)
  • [4] A Glucose Biosensor Based on Immobilization of Glucose Oxidase into 3D Macroporous TiO2
    Cao, Huimin
    Zhu, Yihua
    Tang, Longhua
    Yang, Xiaoling
    Li, Chunzhong
    [J]. ELECTROANALYSIS, 2008, 20 (20) : 2223 - 2228
  • [5] Oligonucleotides-based biosensors with high sensitivity and selectivity for mercury using electrochemical impedance spectroscopy
    Cao, Rui-Guo
    Zhu, Bin
    Li, Jingjian
    Xu, Dongsheng
    [J]. ELECTROCHEMISTRY COMMUNICATIONS, 2009, 11 (09) : 1815 - 1818
  • [6] Photosensitized degradation of dyes in polyoxometalate solutions versus TiO2 dispersions under visible-light irradiation:: Mechanistic implications
    Chen, CC
    Zhao, W
    Lei, PX
    Zhao, JC
    Serponer, N
    [J]. CHEMISTRY-A EUROPEAN JOURNAL, 2004, 10 (08) : 1956 - 1965
  • [7] Modification of silica nanoparticles with fluorescein hydrozide for Cu(II) sensing
    Chen, Xiaotong
    Tong, Aijun
    [J]. DYES AND PIGMENTS, 2012, 95 (03) : 776 - 783
  • [8] Aptamer biosensor for label-free impedance spectroscopy detection of potassium ion based on DNA G-quadruplex conformation
    Chen, Zhengbo
    Chen, Liang
    Ma, He
    Zhou, Tong
    Li, Xiaoxiao
    [J]. BIOSENSORS & BIOELECTRONICS, 2013, 48 : 108 - 112
  • [9] Solvent-assisted selective detection of sub-micromolar levels of Cu2+ ions in aqueous samples and live-cells
    Chereddy, Narendra Reddy
    Janakipriya, Subramaniyan
    Korrapati, Purna Sai
    Thennarasu, Sathiah
    Mandal, Asit Baran
    [J]. ANALYST, 2013, 138 (04) : 1130 - 1136
  • [10] Membrane Composition Effects on the Analytical Behavior of Solid Contact Potentiometric Pb2+ Selective Electrodes Based on Diazadibenzo-18-crown-6 Ionophores
    Cuervo Ochoa, G.
    Aguilar-Cordero, J. C.