Uterine Perforation with the Levonorgestrel-Releasing Intrauterine Device Analysis of Reports from Four National Pharmacovigilance Centres

被引:25
作者
van Grootheest, Kees [1 ,2 ]
Sachs, Bernhardt [3 ]
Harrison-Woolrych, Mira [4 ]
Caduff-Janosa, Pia [5 ]
van Puijenbroek, Eugene [1 ]
机构
[1] Netherlands Pharmacovigilance Ctr Lareb, NL-5237 MH Shertogenbosch, Netherlands
[2] Univ Groningen, Dept Pharm, Sect Pharmacotherapy & Pharmaceut Care, Groningen, Netherlands
[3] Fed Inst Drugs & Med Devices BfArM, Div Pharmacovigilance, Bonn, Germany
[4] Univ Otago, Dept Prevent & Social Med, Intens Med Monitoring Programme, Dunedin, New Zealand
[5] Swiss Agcy Therapeut Prod, Div Safety Med, Unit Vigilance, Bern, Switzerland
关键词
SYSTEM; INSERTION; WOMEN; RISK;
D O I
10.2165/11585050-000000000-00000
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Levonorgestrel-releasing intrauterine devices (LNG-IUD) are commonly used for contraception and other indications in many countries. National pharmacovigilance centres have been receiving reports from healthcare professionals and patients of uterine perforation associated with the use of these LNG-IUDs. Methods: National pharmacovigilance centres in the Netherlands, New Zealand, Switzerland and Germany did a search on their adverse drug reaction databases for reports of cases of uterine perforation after insertion of a LNG-IUD received between the introduction of the LNG-IUD onto the market in the late 1990s and 15 July 2007. The number of women affected and patient characteristics such as age, parity and breastfeeding status were examined. In addition, the method of detection of the perforation and the time until discovery of the perforation were analysed. Results: Between the introduction of the LNG-IUD onto the market in each country and 15 July 2007, 701 cases of uterine perforation with a LNG-IUD were reported; 8.5% of the perforations were detected at the time of insertion. Abdominal pain and control/check-up visits were the most common events that lead to the detection of a perforation. Of 462 women known to be parous, 192(42%) were breastfeeding at the time the perforation was discovered. Conclusions: Uterine perforations can be asymptomatic and may remain undetected for a long time after IUD insertion. Abdominal pain, control/check-up visits or changes in bleeding patterns are triggers for detection of perforation and should therefore be taken seriously.
引用
收藏
页码:83 / 88
页数:6
相关论文
共 27 条
  • [1] Levonorgestrel-releasing intrauterine device (LNG-IUD) for symptomatic endometriosis following surgery
    Abou-Setta, A. M.
    Al-Inany, H. G.
    Farquhar, C. M.
    [J]. COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2006, (04):
  • [2] Perforations with intrauterine devices - Report from a Swedish survey
    Andersson, K
    Ryde-Blomqvist, E
    Lindell, K
    Odlind, V
    Milsom, I
    [J]. CONTRACEPTION, 1998, 57 (04) : 251 - 255
  • [3] [Anonymous], 2004, COCHRANE DB SYST REV, DOI DOI 10.1002/14651858.CD001776.PUB2
  • [4] Use of the levonorgestrel-releasing intrauterine system and breast cancer
    Backman, T
    Rauramo, I
    Jaakkola, K
    Inki, P
    Vaahtera, K
    Launonen, A
    Koskenvuo, M
    [J]. OBSTETRICS AND GYNECOLOGY, 2005, 106 (04) : 813 - 817
  • [5] Benefit-risk-assessment of the levonorgestrel intrauterine system in contraception
    Backman, T
    [J]. DRUG SAFETY, 2004, 27 (15) : 1185 - 1204
  • [6] Pregnancy during the use of levonorgestrel intrauterine system
    Backman, T
    Rauramo, I
    Huhtala, S
    Koskenvuo, M
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 190 (01) : 50 - 54
  • [7] Boutet G, 2006, Gynecol Obstet Fertil, V34, P1015, DOI 10.1016/j.gyobfe.2006.09.015
  • [8] Ileal penetration by a Multiload-Cu 375® intrauterine contraceptive device -: A case report with review of the literature
    Chen, CP
    Hsu, TC
    Wang, W
    [J]. CONTRACEPTION, 1998, 58 (05) : 295 - 304
  • [9] CERVICAL DILATATION IN INTERVAL INSERTION OF AN IUD - WHO REQUIRES IT AND DOES IT LEAD TO A HIGH EXPULSION RATE
    CHI, IC
    CHAMPION, CB
    WILKENS, LR
    [J]. CONTRACEPTION, 1987, 36 (04) : 403 - 415
  • [10] PERFORMANCE OF THE COPPER T-380A INTRAUTERINE-DEVICE IN BREASTFEEDING WOMEN