Implementation and application of PyNE sub-voxel R2S for shutdown dose rate analysis

被引:0
|
作者
Zhang, Xiaokang [1 ]
Shriwise, Patrick C. [2 ]
Liu, Songlin [1 ]
Wilson, Paul P. H. [3 ]
机构
[1] Chinese Acad Sci, Hefei Inst Phys Sci, Inst Plasma Phys, Hefei 230031, Peoples R China
[2] Argonne Natl Lab, 9700 S Cass Ave, Argonne, IL 60439 USA
[3] Univ Wisconsin, 1500 Engn Dr, Madison, WI 53706 USA
基金
中国国家自然科学基金; 中国博士后科学基金; 国家重点研发计划;
关键词
shutdown dose rate; R2S; sub-voxel; PyNE; VERIFICATION; BENCHMARKING; VALIDATION; GEOMETRY; PROPOSAL; MESH;
D O I
10.1088/2058-6272/ac6be3
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
PyNE R2S is a mesh-based R2S implementation with the capability of performing shutdown dose rate (SDR) analysis directly on CAD geometry with Cartesian or tetrahedral meshes. It supports advanced variance reduction for fusion energy systems. However, the assumption of homogenized materials of PyNE R2S with a Cartesian mesh throughout a mesh voxel introduces an approximation in the case where a voxel covers multiple non-void cells. This work implements a sub-voxel method to add fidelity to PyNE R2S with a Cartesian mesh during the process of activation and photon source sampling by performing independent inventory calculations for each cell within a mesh voxel and using the results of those independent calculations to sample the photon source more precisely. PyNE sub-voxel R2S has been verified with the Frascati Neutron Generator (FNG)-ITER and ITER computational shutdown dose rate benchmark problems. The results for sub-voxel R2S show satisfactory agreement with the experimental values or reference results. PyNE sub-voxel R2S has been applied to the shutdown dose rate calculation of the Chinese Fusion Engineering Testing Reactor (CFETR). In conclusion, sub-voxel R2S is a reliable tool for SDR calculation and obtains more accurate results with the same voxel size than voxel R2S.
引用
收藏
页数:7
相关论文
共 24 条
  • [11] Development of unstructured mesh tally capability in cosRMC and application to shutdown dose rate analysis
    Zhang, Xian
    Liu, Shichang
    Wang, Zhenyu
    Chen, Yixue
    FUSION ENGINEERING AND DESIGN, 2022, 181
  • [12] Development of shutdown dose rate calculation code based on cosRMC and application to benchmark analysis
    Zhang, Xian
    Liu, Shichang
    Lu, Peng
    Zhang, Xiaokang
    Zheng, Yu
    Chen, Yixue
    Liu, Songlin
    FUSION ENGINEERING AND DESIGN, 2021, 173
  • [13] Transmutation Approximations for the Application of Hybrid Monte Carlo/Deterministic Neutron Transport to Shutdown Dose Rate Analysis
    Biondo, Elliott D.
    Wilson, Paul P. H.
    NUCLEAR SCIENCE AND ENGINEERING, 2017, 187 (01) : 27 - 48
  • [14] Verification and validation of the R2Smesh approach for the calculation of high resolution shutdown dose rate distributions
    Majerle, Mitja
    Leichtle, Dieter
    Fischer, Ulrich
    Serikov, Arkady
    FUSION ENGINEERING AND DESIGN, 2012, 87 (5-6) : 443 - 447
  • [15] Analysis of discrepancies between D1S and R2S results of 2016 DD JET Campaign
    Alguacil, J.
    Catalan, J. P.
    Sauvan, P.
    Villari, R.
    Batistoni, P.
    Sanz, J.
    NUCLEAR FUSION, 2022, 62 (09)
  • [16] Rate-sensitive analysis of framed structures .2. Implementation and application to steel and R/C frames
    Fang, Q
    Izzuddin, BA
    STRUCTURAL ENGINEERING AND MECHANICS, 1997, 5 (03) : 239 - 256
  • [17] Application of R2S unstructured tetrahedral mesh method to radioactive concrete structure dismantling using AETIUS/FISPACT codes
    Kim, Jong W.
    Cho, Jin Y.
    Lee, Young-Ouk
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2020, 44 (10) : 8181 - 8192
  • [18] RayActive: An all-in-one R2S neutron induced activation analysis tool based on new intrinsic resolution methods.
    Dray, N.
    Suraud, E.
    Dossat, C.
    Chatry, N.
    NUCLEAR ENGINEERING AND DESIGN, 2022, 386
  • [19] FACILE SYNTHESIS OF (2R,3R)-PHENYLALANINE-2,3-D2 AND ITS APPLICATION TO CONFORMATIONAL-ANALYSIS OF GRAMICIDIN-S
    TANIMURA, K
    KATO, T
    WAKI, M
    IZUMIYA, N
    TETRAHEDRON LETTERS, 1983, 24 (35) : 3737 - 3740
  • [20] The Degradation Rate Study of Methyl Orange Using MWCNTs@TiO2 as Photocatalyst, Application of Statistical Analysis Based on Fisher’s F Distribution
    Sedigheh Abbasi
    Journal of Cluster Science, 2022, 33 : 593 - 602