Modelling for post-dryout heat transfer and droplet sizes at low pressure and low flow conditions

被引:5
作者
Jeong, HY
No, HC
机构
[1] Department of Nuclear Engineering, Korea Adv. Inst. Sci. and Technol., Yusung-gu, Taejon 305-701
关键词
D O I
10.1016/0735-1933(96)00060-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
A correlation describing the initial droplet size just after the CRF position at low mass flux is suggested through regression analysis. The history-dependent post-dryout model of Varone and Rohsenow replaced by the Webb-Chen model for wall-vapor heat transfer is used as a reference model in the analysis. In the post-dryout region at low pressure and low flow, it is found that the suggested one-dimensional mechanistic model is valid only in the churn-turbulent how regime (j(g)* = 0.5 similar to 4.5). It is also suggested that the droplet size generated from the churn-turbulent surface is dependent not only on the pressure but also on the vapor velocity. It turns out that the present model can predict the measured cladding and vapor temperatures within 20% and 15%, respectively.
引用
收藏
页码:767 / 778
页数:12
相关论文
共 22 条
[1]  
ANDREANI M., 1992, THESIS SWISS FEDERAL
[2]  
ARDRON K. H., 1981, RDB5007N81 CEGB BERK
[3]  
BARTAK J, 1994, P INT C NEW TRENDS N, V1, P297
[4]   VAPOR HEAT-TRANSFER IN POST-CHF REGION INCLUDING EFFECT OF THERMODYNAMIC NONEQUILIBRIUM [J].
CHEN, JC ;
OZKAYNAK, FT ;
SUNDARAM, RK .
NUCLEAR ENGINEERING AND DESIGN, 1979, 51 (02) :143-155
[5]  
DORE P., 1991, AEARS1064
[6]  
EVANS DG, 1983, NUREGCR3363 NRC
[7]  
ewitt D.M. N., 1954, Trans Inst Chem Eng, V32, P244, DOI DOI 10.1016/J.NEUBIOREV.2012.07.005
[8]  
Garner F.H., 1954, Chemical Engineering Research and Design, V32, P222
[9]  
GOTTULA RC, 1985, NUREGCR319 NRC
[10]   PREDICTION OF THERMAL NONEQUILIBRIUM IN POST-DRYOUT REGIME [J].
GROENEVELD, DC ;
DELORME, GGJ .
NUCLEAR ENGINEERING AND DESIGN, 1976, 36 (01) :17-26