Fast evaluation of the likelihood of an HMM: Ion channel currents with filtering and colored noise

被引:21
作者
Fredkin, DR [1 ]
Rice, JA
机构
[1] Univ Calif San Diego, Dept Phys, La Jolla, CA 92093 USA
[2] Univ Calif Berkeley, Dept Stat, Berkeley, CA 94720 USA
关键词
D O I
10.1109/78.905892
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Hidden Markov models (HMMs) have been used in the study of single-channel recordings of ion channel currents for restoration of idealized signals from noisy recordings and for estimation of kinetic parameters, A key to their effectiveness from a computational point of view is that the number of operations to evaluate the likelihood, posterior probabilities and the most likely state sequence is proportional to the product of the square of the dimension of the state space and the length of the series, However, when the state space is quite large, computations can become infeasible, This can happen when the record has been low pass filtered and when the noise is colored. In this paper, we present an approximate method that can provide very substantial reductions in computational cost at the expense of only a very small error. we describe the method and illustrate through examples the gains that can be made in evaluating the likelihood.
引用
收藏
页码:625 / 633
页数:9
相关论文
共 20 条
[1]  
Aho A.V., 1974, The Design and Analysis of Computer Algorithms
[2]   ESTIMATION OF KINETIC RATE CONSTANTS FROM MULTICHANNEL RECORDINGS BY A DIRECT FIT OF THE TIME-SERIES [J].
ALBERTSEN, A ;
HANSEN, UP .
BIOPHYSICAL JOURNAL, 1994, 67 (04) :1393-1403
[3]   A MAXIMIZATION TECHNIQUE OCCURRING IN STATISTICAL ANALYSIS OF PROBABILISTIC FUNCTIONS OF MARKOV CHAINS [J].
BAUM, LE ;
PETRIE, T ;
SOULES, G ;
WEISS, N .
ANNALS OF MATHEMATICAL STATISTICS, 1970, 41 (01) :164-&
[4]   CHARACTERIZATION OF SINGLE CHANNEL CURRENTS USING DIGITAL SIGNAL-PROCESSING TECHNIQUES BASED ON HIDDEN MARKOV-MODELS [J].
CHUNG, SH ;
MOORE, JB ;
XIA, L ;
PREMKUMAR, LS ;
GAGE, PW .
PHILOSOPHICAL TRANSACTIONS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 1990, 329 (1254) :265-285
[5]  
COLQUHOUN D, 1995, SINGLE CHANNEL RECOR, pCH18
[6]   GATING KINETICS OF BATRACHOTOXIN-MODIFIED NA(+) CHANNELS IN THE SQUID GIANT-AXON - VOLTAGE AND TEMPERATURE EFFECTS [J].
CORREA, AM ;
BEZANILLA, F ;
LATORRE, R .
BIOPHYSICAL JOURNAL, 1992, 61 (05) :1332-1352
[7]  
COX D. R., 2000, Theoretical Statistics
[8]  
Fletcher R., 1981, PRACTICAL METHODS OP
[9]   BAYESIAN RESTORATION OF SINGLE-CHANNEL PATCH CLAMP RECORDINGS [J].
FREDKIN, DR ;
RICE, JA .
BIOMETRICS, 1992, 48 (02) :427-448
[10]   MAXIMUM-LIKELIHOOD-ESTIMATION AND IDENTIFICATION DIRECTLY FROM SINGLE-CHANNEL RECORDINGS [J].
FREDKIN, DR ;
RICE, JA .
PROCEEDINGS OF THE ROYAL SOCIETY B-BIOLOGICAL SCIENCES, 1992, 249 (1325) :125-132