Comparative Analysis of von Willebrand Factor Profiles in Pulsatile and Continuous Left Ventricular Assist Device Recipients

被引:84
作者
Crow, Sheri [1 ]
Milano, Carmelo [2 ]
Joyce, Lyle [3 ]
Chen, Dong [4 ]
Arepally, Gowthami [5 ]
Bowles, Dawn [2 ]
Thomas, William [6 ]
Ortiz, Nestor Villamizar [2 ]
机构
[1] Mayo Clin, Div Pediat Crit Care Med, Rochester, MN 55905 USA
[2] Duke Univ, Div Cardiothorac Surg, Durham, NC USA
[3] Mayo Clin, Div Cardiothorac Surg, Rochester, MN 55905 USA
[4] Mayo Clin, Dept Lab Med & Pathol, Rochester, MN 55905 USA
[5] Duke Univ, Div Hematol, Durham, NC USA
[6] Univ Minnesota, Sch Publ Hlth, Div Biostat, Minneapolis, MN 55455 USA
关键词
AORTIC-STENOSIS; SHEAR-STRESS; DISEASE; ANGIODYSPLASIA;
D O I
10.1097/MAT.0b013e3181e5de0a
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A higher rate of nonsurgical bleeding has been observed in nonpulsatile left ventricular assist device (LVAD) recipients. von Willebrand factor (vWF) profiles were compared for nonpulsatile and pulsatile LVAD recipients to explore mechanisms that may contribute to the development of postimplant nonsurgical bleeding. The nonpulsatile mechanism may impair vWF function by creating a deficiency in vWF high molecular weight multimers (HMWMs), essential for hemostasis. High molecular weight multimer deficiency should result in low ristocetin cofactor (RCo) to vWF antigen ratios (vWF:RCo/vWF:Ag) because of impaired platelet (plt)-binding ability. von Willebrand factor profiles and HMWM were measured pre- and post-LVAD placement in 11 nonpulsatile (HeartMate II [HM II[) and 3 pulsatile (HeartMate XVE [HM XVE]) recipients. All the nonpulsatile LVAD recipients exhibited loss of HMWM 30 days postimplant. The vWF:RCo/vWF:Ag ratio was significantly lower after LVAD placement in the nonpulsatile group when compared with the pulsatile group. In addition, the vWF:RCo/vWF:Ag ratio decreased significantly from baseline 30 days postimplant within the nonpulsatile recipients. All nonpulsatile LVAD recipients had low vWF:RCo/vWF:Ag ratios 30 days post-LVAD even if the values were normal at baseline. These data suggest that nonpulsatile HM II recipients develop HMWM loss and impaired vWF platelet (plt)-binding ability after LVAD placement. Similar results were not observed in our small series of pulsatile HM XVE recipients. This finding could suggest a contributing factor to the increase in nonsurgical bleeding observed in nonpulsatile LVAD patients. Further investigation is ongoing to identify specific causes of vWF impairment. ASAIO Journal 2010; 56:441-445.
引用
收藏
页码:441 / 445
页数:5
相关论文
共 16 条
[1]   Gastrointestinal bleeding rates in recipients of nonpulsatile and pulsatile left ventricular assist devices [J].
Crow, Sheri ;
John, Ranjit ;
Boyle, Andrew ;
Shumway, Sara ;
Liao, Kenneth ;
Colvin-Adams, Monica ;
Toninato, Carol ;
Missov, Emil ;
Pritzker, Marc ;
Martin, Cindy ;
Garry, Daniel ;
Thomas, William ;
Joyce, Lyle .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (01) :208-215
[2]   von Willebrand factor: Measuring its antigen or function? Correlation between the level of antigen, activity, and multimer size using various detection systems [J].
Fischer, BE ;
Thomas, KB ;
Dorner, F .
THROMBOSIS RESEARCH, 1998, 91 (01) :39-43
[3]   Non-surgical bleeding in patients with ventricular assist devices could be explained by acquired von Willebrand disease [J].
Geisen, Ulrich ;
Heilmann, Claudia ;
Beyersdorf, Friedhelm ;
Benk, Christoph ;
Berchtold-Herz, Michael ;
Schlensak, Christian ;
Budde, Ulrich ;
Zieger, Barbara .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (04) :679-684
[4]  
HEYDE EC, 1958, NEW ENGL J MED, V259, P196
[5]   Severely Impaired von Willebrand Factor-Dependent Platelet Aggregation in Patients With a Continuous-Flow Left Ventricular Assist Device (HeartMate II) [J].
Klovaite, Jolanta ;
Gustafsson, Finn ;
Mortensen, Svend A. ;
Sander, Kare ;
Nielsen, Lars B. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (23) :2162-2167
[6]   Shear stress and the role of high molecular weight von Willebrand factor multimers in thrombus formation [J].
López, JA ;
Dong, JF .
BLOOD COAGULATION & FIBRINOLYSIS, 2005, 16 :S11-S16
[7]   Acquired von Willebrand syndrome after exchange of the HeartMate XVE to the HeartMate II ventricular assist device [J].
Malehsa, Doris ;
Meyer, Anna L. ;
Bara, Christoph ;
Strueber, Martin .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (06) :1091-1093
[8]   Use of a continuous-flow device in patients awaiting heart transplantation [J].
Miller, Leslie W. ;
Pagani, Francis D. ;
Russell, Stuart D. ;
John, Ranjit ;
Boyle, Andrew J. ;
Aaronson, Keith D. ;
Conte, John V. ;
Naka, Yoshifumi ;
Mancini, Donna ;
Delgado, Reynolds M. ;
MacGillivray, Thomas E. ;
Farrar, David J. ;
Frazier, O. H. .
NEW ENGLAND JOURNAL OF MEDICINE, 2007, 357 (09) :885-896
[9]  
PEDROTTY DM, 2009, ISHLI 29 ANN M PAR
[10]   Long-term use of a left ventricular assist device for end-stage heart failure [J].
Rose, EA ;
Gelijns, AC ;
Moskowitz, AJ ;
Heitjan, DF ;
Stevenson, LW ;
Dembitsky, W ;
Long, JW ;
Ascheim, DD ;
Tierney, AR ;
Levitan, RG ;
Watson, JT ;
Meier, P .
NEW ENGLAND JOURNAL OF MEDICINE, 2001, 345 (20) :1435-1443