Validation of Automated Perfusion-Weighted Phase-Resolved Functional Lung (PREFUL)-MRI in Patients With Pulmonary Diseases

被引:53
作者
Behrendt, Lea [1 ,2 ,3 ]
Voskrebenzev, Andreas [1 ,2 ,3 ]
Klimes, Filip [1 ,2 ,3 ]
Gutberlet, Marcel [1 ,2 ,3 ]
Winther, Hinrich B. [1 ]
Kaireit, Till F. [1 ,2 ,3 ]
Alsady, Tawfik Moher [1 ,2 ,3 ]
Poehler, Gesa H. [1 ,2 ,3 ]
Derlin, Thorsten [4 ]
Wacker, Frank [1 ,2 ,3 ]
Vogel-Claussen, Jens [1 ,2 ,3 ]
机构
[1] Hannover Med Sch, Dept Diagnost & Intervent Radiol, Carl Neuberg Str 1, D-30625 Hannover, Germany
[2] Biomed Res Endstage & Obstruct Lung Dis BREATH, Hannover, Germany
[3] German Ctr Lung Res DZL, Hannover, Germany
[4] Hannover Med Sch, Dept Nucl Med, Hannover, Germany
关键词
PREFUL; Fourier decomposition; lung MRI; dynamic contrast enhanced MRI; perfusion; validation; BOLUS-TRACKING DATA; FOURIER DECOMPOSITION; GADOLINIUM DEPOSITION; MRI; DECONVOLUTION; VENTILATION; COPD;
D O I
10.1002/jmri.27027
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Perfusion-weighted (Qw) noncontrast-enhanced proton lung MRI is a promising technique for assessment of pulmonary perfusion, but still requires validation. Purpose To improve perfusion-weighted phase-resolved functional lung (PREFUL)-MRI, to validate PREFUL with perfusion single photon emission computed tomography (SPECT) as a gold standard, and to compare PREFUL with dynamic contrast-enhanced (DCE)-MRI as a reference. Study Type: Retrospective. Population Twenty patients with chronic obstructive pulmonary disease (COPD), 14 patients with cystic fibrosis (CF), and 21 patients with chronic thromboembolic pulmonary hypertension (CTEPH) were included. Field Strength/Sequence For PREFUL-MRI, a spoiled gradient echo sequence and for DCE-MRI a 3D time-resolved angiography with stochastic trajectories sequence were used at 1.5T. Assessment PREFUL-MRI coronal slices were acquired in free-breathing. DCE-MRI was performed in breath-hold with injection of 0.03 mmol/kg bodyweight of gadoteric acid at a rate of 4 cc/s. Perfusion SPECT images were obtained for six CTEPH patients. Images were coregistered. An algorithm to define the appropriate PREFUL perfusion phase was developed using perfusion SPECT data. Perfusion defect percentages (QDP) and Qw-values were calculated for all methods. For PREFUL quantitative perfusion values (PREFULQ) and for DCE pulmonary blood flow (PBF) was calculated. Statistical Tests Obtained parameters were assessed using Pearson correlation and Bland-Altman analysis. Results Qw-SPECT correlated with Qw-DCE (r = 0.50, P < 0.01) and Qw-PREFUL (r = 0.47, P < 0.01). Spatial overlap of QDP maps showed an agreement >= 67.7% comparing SPECT and DCE, >= 64.1% for SPECT and PREFUL, and >= 60.2% comparing DCE and PREFUL. Significant correlations of Qw-PREFUL and Qw-DCE were found (COPD: r = 0.79, P < 0.01; CF: r = 0.77, P < 0.01; CTEPH: r = 0.73, P < 0.01). PREFULQ/PBF correlations were similar/lower (CF, CTEPH: P > 0.12; COPD: P < 0.01) compared to Qw-PREFUL/DCE correlations. PREFULQ-values were higher/similar compared to PBF-values (COPD, CF: P < 0.01; CTEPH: P = 0.026). Data Conclusion The automated PREFUL algorithm may allow for noncontrast-enhanced pulmonary perfusion assessment in COPD, CF, and CTEPH patients comparable to DCE-MRI. Level of Evidence 3 Technical Efficacy Stage 2
引用
收藏
页码:103 / 114
页数:12
相关论文
共 32 条
  • [1] Editorial for "Validation of Automated Perfusion-Weighted Phase-Resolved Functional Lung (PREFUL)-MRI in Patients With Pulmonary Diseases"
    Beckmann, Nicolau
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 52 (01) : 115 - 116
  • [2] Comparison of quantitative regional perfusion-weighted phase resolved functional lung (PREFUL) MRI with dynamic gadolinium-enhanced regional pulmonary perfusion MRI in COPD patients
    Kaireit, Till F.
    Voskrebenzev, Andreas
    Gutberlet, Marcel
    Freise, Julia
    Jobst, Bertram
    Kauczor, Hans-Ulrich
    Welte, Tobias
    Wacker, Frank
    Vogel-Claussen, Jens
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2019, 49 (04) : 1122 - 1132
  • [3] Diagnostic accuracy of perfusion-weighted phase-resolved functional lung magnetic resonance imaging in patients with chronic pulmonary embolism
    Duan, Jianghui
    Xie, Sheng
    Sun, Hongliang
    An, Jing
    Li, Huan
    Li, Ling
    Grimm, Robert
    Voskrebenzev, Andreas
    Vogel-Claussen, Jens
    FRONTIERS IN MEDICINE, 2023, 10
  • [4] Influence of echo time on pulmonary ventilation and perfusion derived by phase-resolved functional lung (PREFUL) MRI using multi-echo ultrashort echo time acquisition
    Behrendt, Lea
    Gutberlet, Marcel
    Voskrebenzev, Andreas
    Klimes, Filip
    Obert, Arnd J.
    Kern, Agilo L.
    Horstmann, Dominik
    Wernz, Marius M.
    Mueller, Robin A.
    Wacker, Frank
    Vogel-Claussen, Jens
    NMR IN BIOMEDICINE, 2024, 37 (12)
  • [5] Phase-Resolved Functional Lung MRI for Pulmonary Ventilation and Perfusion (V/Q) Assessment
    Voskrebenzev, Andreas
    Klimes, Filip
    Wacker, Frank
    Vogel-Claussen, Jens
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (210):
  • [6] Chronic Thromboembolic Pulmonary Hypertension Perioperative Monitoring Using Phase-Resolved Functional Lung (PREFUL)-MRI
    Poehler, Gesa H.
    Klimes, Filip
    Voskrebenzev, Andreas
    Behrendt, Lea
    Czerner, Christoph
    Gutberlet, Marcel
    Cebotari, Serghei
    Ius, Fabio
    Fegbeutel, Christine
    Schoenfeld, Christian
    Kaireit, Till F.
    Hauck, Erik F.
    Olsson, Karen M.
    Hoeper, Marius M.
    Wacker, Frank
    Vogel-Claussen, Jens
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2020, 52 (02) : 610 - 619
  • [7] Free-breathing quantification of regional ventilation derived by phase-resolved functional lung (PREFUL) MRI
    Klimes, F.
    Voskrebenzev, A.
    Gutberlet, M.
    Kern, A.
    Behrendt, L.
    Kaireit, T. F.
    Czerner, C.
    Renne, J.
    Wacker, F.
    Vogel-Claussen, J.
    NMR IN BIOMEDICINE, 2019, 32 (06)
  • [8] Repeatability of Phase-Resolved Functional Lung (PREFUL)-MRIVentilation and Perfusion Parameters in Healthy Subjects andCOPDPatients
    Poehler, Gesa H.
    Klimes, Filip
    Behrendt, Lea
    Voskrebenzev, Andreas
    Gonzalez, Cristian Crisosto
    Wacker, Frank
    Hohlfeld, Jens M.
    Vogel-Claussen, Jens
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 53 (03) : 915 - 927
  • [9] A dual center and dual vendor comparison study of automated perfusion-weighted phase-resolved functional lung magnetic resonance imaging with dynamic contrast-enhanced magnetic resonance imaging in patients with cystic fibrosis
    Behrendt, Lea
    Smith, Laurie J.
    Voskrebenzev, Andreas
    Klimes, Filip
    Kaireit, Till F.
    Poehler, Gesa H.
    Kern, Agilo L.
    Gonzalez, Cristian Crisosto
    Dittrich, Anna-Maria
    Marshall, Helen
    Schuetz, Katharina
    Hughes, Paul J. C.
    Ciet, Pierluigi
    Tiddens, Harm A. W. M.
    Wild, Jim M.
    Vogel-Claussen, Jens
    PULMONARY CIRCULATION, 2022, 12 (02)
  • [10] Feasibility, Repeatability, and Correlation to Lung Function of Phase-Resolved Functional Lung (PREFUL) MRI-derived Pulmonary Artery Pulse Wave Velocity Measurements
    Wernz, Marius M.
    Voskrebenzev, Andreas
    Mueller, Robin A.
    Zubke, Maximilian
    Klimes, Filip
    Glandorf, Julian
    Czerner, Christoph
    Wacker, Frank
    Olsson, Karen M.
    Hoeper, Marius M.
    Hohlfeld, Jens M.
    Vogel-Claussen, Jens
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (05) : 2216 - 2228