Improved NADH Electroanalysis on Nickel(II) Phthalocyanine Tetrasulfonic Acid/Calf Thymus Deoxyribonucleic Acid/Reduced Graphene Oxide Composite

被引:13
作者
Ribeiro, Izabela Aparecida L. [1 ]
Yotsumoto-Neto, Sakae [2 ]
dos Santos, Wallans T. P. [3 ]
Fernandes, Ridvan N. [2 ]
Goulart, Marilia O. F. [4 ]
Damos, Flavio S. [2 ]
Luz, Rita de Cassia S. [2 ]
机构
[1] Univ Fed Vales Jequitinhonha & Mucuri, Dept Quim, Rodovia MGT 367,Km 583, BR-39100000 Diamantina, MG, Brazil
[2] Univ Fed Maranhao, Dept Quim, BR-65080805 Sao Luis, MA, Brazil
[3] Univ Fed Vales Jequitinhonha & Mucuri, Dept Farm, Rodovia MGT 367,Km 583, BR-39100000 Diamantina, MG, Brazil
[4] Univ Fed Alagoas, Inst Quim & Biotecnol, Av Lourival Melo Mota S-N,Cidade Univ, BR-57072900 Maceio, AL, Brazil
关键词
reduced graphene oxide; CT-DNA; nickel tetrasulfonated phthalocyanine; NADH; electroanalysis; sensor; GLASSY-CARBON ELECTRODE; ELECTROCATALYTIC OXIDATION; ELECTROCHEMICAL SENSOR; AMPEROMETRIC SENSOR; CONDUCTING POLYMER; REDOX MEDIATOR; ASCORBIC-ACID; NANOTUBES; DNA; NANOPARTICLES;
D O I
10.21577/0103-5053.20170030
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
This work describes the electrochemical performance of a novel composite based on nickel tetrasulfonated phthalocyanine (NiTsPc), deoxyribonucleic acid from calf thymus (CT-DNA) and reduced graphene oxide (rGO) for the electroanalysis of reduced beta-nicotinamide adenine dinucleotide (NADH), through electrocatalytic oxidation. The modified electrode was denoted as CT-DNA/NiTsPc/rGO. Fourier transform infrared and ultraviolet-visible spectroscopies were performed to characterize the composite material. The electrochemical performance of the composite for NADH oxidation was investigated by cyclic voltammetry(CV), chronoamperometry and differential pulse voltammetry (DPV). The CT-DNA/NiTsPc/rGO modified glassy carbon electrode (GCE) showed an excellent electrocatalytic activity for NADH oxidation with apparent electrocatalytic rate constant (k(obs)) of 7.35 x 10(5) L mol(-1) s(-1) and linear response range for NADH from 1 up to 1350 mu mol L-1 for n = 12 (r = 0.999). The proposed sensor shows sensitivity, detection limit and quantification limit of 0.014 mu A L mol(-1), 0.3 and 1 mu mol L-1, respectively. The prepared sensor was further tested for the determination of NADH in artificial human urine samples, showing promising biomedical applications.
引用
收藏
页码:1768 / 1778
页数:11
相关论文
共 63 条
[1]  
Aghaie M., 2007, J PHYS THEOR CHEM, V3, P27
[2]  
[Anonymous], 1987, ANALYST, V112, P199
[3]   Electrocatalytic oxidation of NADH at single-wall carbon-nanotube-paste electrodes: kinetic considerations for use of a redox mediator in solution and dissolved in the paste [J].
Antiochia, R ;
Lavagnini, I ;
Magno, F .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 381 (07) :1355-1361
[4]   Thermodynamic and spectroscopic study on the binding of cationic Zn(II) and Co(II) tetrapyridinoporphyrazines to calf thymus DNA: the role of the central metal in binding parameters [J].
Asadi, M ;
Safaei, E ;
Ranjbar, B ;
Hasani, L .
NEW JOURNAL OF CHEMISTRY, 2004, 28 (10) :1227-1234
[5]   Electrochemical sensing of NADH based on Meldola Blue immobilized silver nanoparticle-conducting polymer electrode [J].
Balamurugan, A. ;
Ho, Kun-Cheng ;
Chen, Shen-Ming ;
Huang, Tzu-Yen .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2010, 362 (1-3) :1-7
[6]  
Bard A. J., 2001, ELECTROCHEMICAL METH, P833
[7]   Theoretical and spectroscopic study of nickel(II) porphyrin derivatives [J].
Berrios, Cristhian ;
Cardenas-Jiron, Gloria I. ;
Marco, Jose F. ;
Gutierrez, Claudio ;
Ureta-Zanartu, Maria Soledad .
JOURNAL OF PHYSICAL CHEMISTRY A, 2007, 111 (14) :2706-2714
[8]   An investigation on the self-aggregation properties of sulfonated copper(II) phthalocyanine (CuTsPc) thin films [J].
Bertoncello, Paolo ;
Peruffo, Massimo .
COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2008, 321 (1-3) :106-112
[9]   SiO2/SnO2/Sb2O5 microporous ceramic material for immobilization of Meldola's blue: Application as an electrochemical sensor for NADH [J].
Canevari, Thiago C. ;
Vinhas, Rita C. G. ;
Landers, Richard ;
Gushikem, Yoshitaka .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (05) :2402-2406
[10]  
Castro Jr J.G., 2014, J ELECTROANAL CHEM, V732, P93