Calibration of RGBD camera and cone-beam CT for 3D intra-operative mixed reality visualization

被引:28
作者
Lee, Sing Chun [1 ]
Fuerst, Bernhard [1 ,2 ]
Fotouhi, Javad [1 ]
Fischer, Marius [1 ,3 ]
Osgood, Greg [4 ]
Navab, Nassir [1 ,2 ]
机构
[1] Johns Hopkins Univ, Comp Aided Med Procedures, Baltimore, MD USA
[2] Tech Univ Munich, Comp Aided Med Procedures, D-80290 Munich, Germany
[3] Ludwig Maximilians Univ Munchen, Klinikum Innenstadt, Dept Trauma Surg, Munich, Germany
[4] Johns Hopkins Univ Hosp, Dept Orthopaed Surg, Orthopaed Trauma, Baltimore, MD 21287 USA
关键词
Augmented reality; Cone-beam CT; C-arm; Intra-operative imaging; 3D-3D calibration; NAVIGATION; RADIATION; FLUOROSCOPY; ACCURACY; SYSTEM;
D O I
10.1007/s11548-016-1396-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work proposes a novel algorithm to register cone-beam computed tomography (CBCT) volumes and 3D optical (RGBD) camera views. The co-registered real-time RGBD camera and CBCT imaging enable a novel augmented reality solution for orthopedic surgeries, which allows arbitrary views using digitally reconstructed radiographs overlaid on the reconstructed patient's surface without the need to move the C-arm. An RGBD camera is rigidly mounted on the C-arm near the detector. We introduce a calibration method based on the simultaneous reconstruction of the surface and the CBCT scan of an object. The transformation between the two coordinate spaces is recovered using Fast Point Feature Histogram descriptors and the Iterative Closest Point algorithm. Several experiments are performed to assess the repeatability and the accuracy of this method. Target registration error is measured on multiple visual and radio-opaque landmarks to evaluate the accuracy of the registration. Mixed reality visualizations from arbitrary angles are also presented for simulated orthopedic surgeries. To the best of our knowledge, this is the first calibration method which uses only tomographic and RGBD reconstructions. This means that the method does not impose a particular shape of the phantom. We demonstrate a marker-less calibration of CBCT volumes and 3D depth cameras, achieving reasonable registration accuracy. This design requires a one-time factory calibration, is self-contained, and could be integrated into existing mobile C-arms to provide real-time augmented reality views from arbitrary angles.
引用
收藏
页码:967 / 975
页数:9
相关论文
共 50 条
[41]   The Study on the Implementation of the X-Ray CT System Using the Cone-Beam for the 3D Dynamic Image Acquisition [J].
Jeong, Chan-Woong ;
Jun, Kyu-Suk .
JOURNAL OF THE ACOUSTICAL SOCIETY OF KOREA, 2009, 28 (04) :370-374
[42]   Deep Learning-Based Workflow for Bone Segmentation and 3D Modeling in Cone-Beam CT Orthopedic Imaging [J].
Tiribilli, Eleonora ;
Bocchi, Leonardo .
APPLIED SCIENCES-BASEL, 2024, 14 (17)
[43]   Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT [J].
J. K. Dusseldorp ;
H. C. Stamatakis ;
Y. Ren .
Clinical Oral Investigations, 2017, 21 :921-930
[44]   ADVANCING THE FRONTIERS OF DEEP LEARNING FOR LOW-DOSE 3D CONE-BEAM COMPUTED TOMOGRAPHY (CT) RECONSTRUCTION [J].
Biguri, Ander ;
Mukherjee, Subhadip .
2024 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING WORKSHOPS, ICASSPW 2024, 2024, :81-82
[45]   MRCM-UCTransNet: Automatic and Accurate 3D Tooth Segmentation Network From Cone-Beam CT Images [J].
Wen, Xinyang ;
Liu, Zhuoxuan ;
Chu, Yanbo ;
Le, Min ;
Li, Liang .
INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2024, 34 (04)
[46]   A 3D metal artifact correction method in cone-beam CT bone imaging by using an implant image library [J].
Zhang, Yan ;
Ning, Ruola ;
Conover, David .
MEDICAL IMAGING 2008: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2008, 6913
[47]   Feasibility of differential quantification of 3D temporomandibular kinematics during various oral activities using a cone-beam computed tomography-based 3D fluoroscopic method [J].
Chen, Chien-Chih ;
Lin, Cheng-Chung ;
Lu, Tung-Wu ;
Chiang, Hao ;
Chen, Yunn-Jy .
JOURNAL OF DENTAL SCIENCES, 2013, 8 (02) :151-159
[48]   Application of cone beam CT 3D images to cephalometric analysis [J].
Ogawa, Naoki ;
Miyazaki, Yoshikazu ;
Kubota, Masato ;
Huang, John C. ;
Miller, Arthur J. ;
Maki, Koutaro .
ORTHODONTIC WAVES, 2010, 26 (04) :415-454
[49]   Intra-operative Cone Beam Computed Tomography can Help Avoid Reinterventions and Reduce CT Follow up after Infrarenal EVAR [J].
Tornqvist, P. ;
Dias, N. ;
Sonesson, B. ;
Kristmundsson, T. ;
Resch, T. .
EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2015, 49 (04) :390-395
[50]   Integration of free-hand 3D ultrasound and mobile C-arm cone-beam CT: Feasibility and characterization for real-time guidance of needle insertione [J].
Marinetto, E. ;
Uneri, A. ;
De Silva, T. ;
Reaungamornrat, S. ;
Zbijewski, W. ;
Sisniega, A. ;
Vogt, S. ;
Kleinszig, G. ;
Pascau, J. ;
Siewerdsen, J. H. .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2017, 58 :13-22