Calibration of RGBD camera and cone-beam CT for 3D intra-operative mixed reality visualization

被引:28
作者
Lee, Sing Chun [1 ]
Fuerst, Bernhard [1 ,2 ]
Fotouhi, Javad [1 ]
Fischer, Marius [1 ,3 ]
Osgood, Greg [4 ]
Navab, Nassir [1 ,2 ]
机构
[1] Johns Hopkins Univ, Comp Aided Med Procedures, Baltimore, MD USA
[2] Tech Univ Munich, Comp Aided Med Procedures, D-80290 Munich, Germany
[3] Ludwig Maximilians Univ Munchen, Klinikum Innenstadt, Dept Trauma Surg, Munich, Germany
[4] Johns Hopkins Univ Hosp, Dept Orthopaed Surg, Orthopaed Trauma, Baltimore, MD 21287 USA
关键词
Augmented reality; Cone-beam CT; C-arm; Intra-operative imaging; 3D-3D calibration; NAVIGATION; RADIATION; FLUOROSCOPY; ACCURACY; SYSTEM;
D O I
10.1007/s11548-016-1396-1
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This work proposes a novel algorithm to register cone-beam computed tomography (CBCT) volumes and 3D optical (RGBD) camera views. The co-registered real-time RGBD camera and CBCT imaging enable a novel augmented reality solution for orthopedic surgeries, which allows arbitrary views using digitally reconstructed radiographs overlaid on the reconstructed patient's surface without the need to move the C-arm. An RGBD camera is rigidly mounted on the C-arm near the detector. We introduce a calibration method based on the simultaneous reconstruction of the surface and the CBCT scan of an object. The transformation between the two coordinate spaces is recovered using Fast Point Feature Histogram descriptors and the Iterative Closest Point algorithm. Several experiments are performed to assess the repeatability and the accuracy of this method. Target registration error is measured on multiple visual and radio-opaque landmarks to evaluate the accuracy of the registration. Mixed reality visualizations from arbitrary angles are also presented for simulated orthopedic surgeries. To the best of our knowledge, this is the first calibration method which uses only tomographic and RGBD reconstructions. This means that the method does not impose a particular shape of the phantom. We demonstrate a marker-less calibration of CBCT volumes and 3D depth cameras, achieving reasonable registration accuracy. This design requires a one-time factory calibration, is self-contained, and could be integrated into existing mobile C-arms to provide real-time augmented reality views from arbitrary angles.
引用
收藏
页码:967 / 975
页数:9
相关论文
共 50 条
[31]   Using cone-beam CT as a low-dose 3D imaging technique for the extremities: initial experience in 50 subjects [J].
Huang, Ambrose J. ;
Chang, Connie Y. ;
Thomas, Bijoy J. ;
MacMahon, Peter J. ;
Palmer, William E. .
SKELETAL RADIOLOGY, 2015, 44 (06) :797-809
[32]   Marker-less real-time intra-operative camera and hand-eye calibration procedure for surgical augmented reality [J].
Kalia, Megha ;
Mathur, Prateek ;
Navab, Nassir ;
Salcudean, Septimiu E. .
HEALTHCARE TECHNOLOGY LETTERS, 2019, 6 (06) :255-260
[33]   Performance of a feature-based algorithm for 3D-3D registration of CT angiography to cone-beam CT for endovascular repair of complex abdominal aortic aneurysms [J].
Koutouzi, Giasemi ;
Nasihatkton, Behrooz ;
Danielak-Nowak, Monika ;
Leonhardt, Henrik ;
Falkenberg, Marten ;
Kahl, Fredrik .
BMC MEDICAL IMAGING, 2018, 18
[34]   3D CT pancreatography vs. cone beam CT pancreatography [J].
Ueno, J ;
Kitagawa, M ;
Makimoto, Y ;
Matsuzaki, K ;
Yoshida, S ;
Nishitani, H .
CARS '99: COMPUTER ASSISTED RADIOLOGY AND SURGERY, 1999, 1191 :982-982
[35]   Twin robotic x-ray system for 2D radiographic and 3D cone-beam CT imaging [J].
Fieselmann, Andreas ;
Steinbrener, Jan ;
Jerebko, Anna K. ;
Voigt, Johannes M. ;
Scholz, Rosemarie ;
Ritschl, Ludwig ;
Mertelmeier, Thomas .
MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
[36]   Reliability of the Planned Pedicle Screw Trajectory versus the Actual Pedicle Screw Trajectory using Intra-operative 3D CT and Image Guidance [J].
Miller, Catherine A. ;
Ledonio, Charles G. ;
Hunt, Matthew A. ;
Siddiq, Farhan ;
Polly, David W., Jr. .
INTERNATIONAL JOURNAL OF SPINE SURGERY, 2016, 10
[37]   The correlation between intra-operative 2D-and 3D fluoroscopy with postoperative CT-scans in the treatment of calcaneal fractures [J].
Beerekamp, M. S. H. ;
Keizer, R. J. O. de Muinck ;
Schepers, T. ;
Beenen, L. F. M. ;
Luitse, J. S. K. ;
Schep, N. W. ;
Ubbink, D. T. ;
Goslings, J. C. ;
Segers, M. J. M. ;
Blokhuis, T. J. ;
de Jong, V. M. ;
Winkelhagen, J. ;
Twigt, B. ;
Maas, M. .
EUROPEAN JOURNAL OF RADIOLOGY, 2019, 112 :222-228
[38]   Soft tissue coverage on the segmentation accuracy of the 3D surface-rendered model from cone-beam CT [J].
Dusseldorp, J. K. ;
Stamatakis, H. C. ;
Ren, Y. .
CLINICAL ORAL INVESTIGATIONS, 2017, 21 (03) :921-930
[39]   Relaxed Statistical Shape Models for 3D Image Segmentation - Application to Mandible Bone in Cone-beam CT Data [J].
Gollmer, Sebastian T. ;
Buzug, Thorsten M. .
CURRENT MEDICAL IMAGING REVIEWS, 2013, 9 (02) :129-137
[40]   Evaluation of dental and basal arch forms using cone-beam CT and 3D virtual models of normal occlusion [J].
Bayome, Mohamed ;
Park, Jae Hyun ;
Han, Seong Ho ;
Baek, Seung-Hak ;
Sameshima, Glenn T. ;
Kook, Yoon-Ah .