Effects of posture and prolonged pneumoperitoneum on hemodynamic parameters during laparoscopy

被引:65
|
作者
Meininger, Dirk [1 ]
Westphal, Klaus [2 ]
Bremerich, Dorothee H. [3 ]
Runkel, Heiner [1 ]
Probst, Michael [4 ]
Zwissler, Bernhard [1 ]
Byhahn, Christian [1 ]
机构
[1] JW Goethe Univ Hosp, Dept Anesthesiol Intens Care Med & Pain Control, D-60596 Frankfurt, Germany
[2] Katharina Kasper Kliniken, Dept Anesthesiol & Intens Care Med, D-60318 Frankfurt, Germany
[3] St Vincenz Hosp, Dept Anesthesiol & Intens Care Med, D-65549 Limburg, Germany
[4] JW Goethe Univ Hosp, Dept Urol & Pediat Urol, D-60596 Frankfurt, Germany
关键词
D O I
10.1007/s00268-007-9424-5
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The present prospective study was designed to evaluate hemodynamic changes associated with head-down positioning and prolonged pneumoperitoneum during totally endoscopic robot-assisted radical prostatectomy. Methods Ten American Society of Anesthesiologists (ASA) physical status I-III patients undergoing totally endoscopic robot-assisted radical prostatectomy were enrolled in the study. Invasive hemodynamic parameters were measured by transpulmonary arterial thermodilution using the PiCCO(R) system with a femoral artery catheter. Cardiac index (CI), heart rate (HR), mean arterial pressure (MAP), systemic vascular resistance index (SVRI), intrathoracic blood volume (ITBV), and central venous pressure (CVP) were recorded with the patient in the supine position, after head-down tilt, intraoperatively after 30 min, 1 h, 2 h, 3 h, and 4 h of pneumoperitoneum at an insufflation pressure of 12 mmHg, after deflation still with head-down positioning, and finally, with the patient in the supine position. Results Placing the patient in the Trendelenburg (head-down) position caused a significant increase in CVP (from 9.9 +/- 3.4 to 15.1 +/- 2.3 mmHg), whereas all other hemodynamic parameters remained nearly unaffected. The induction of pneumoperitoneum resulted in a significant increase in MAP (from 74.9 +/- 12.9 to 95.4 +/- 11.9 mmHg). No other parameter was affected. Even at 4 h of pneumoperitoneum only mild hemodynamic changes were observed. After release of the pneumoperitoneum with the patient still in the head-down position, HR (49.0 +/- 4 versus 63.9 +/- 12.4 min(-1)) and after placing the patient in the supine position, CI (2.4 +/- 0.2 versus 3.3 +/- 0.7 l min(-1)m(-2)) increased significantly, whereas CVP returned to baseline values. Conclusions Patients undergoing totally endoscopic radical prostatectomy with 4 h of pneumoperitoneum in the Trendelenburg position experienced no significant hemodynamic depression during posture and pneumoperitoneum.
引用
收藏
页码:1400 / 1405
页数:6
相关论文
共 50 条
  • [31] Cardiac Effects of Carbon Dioxide Pneumoperitoneum in Veterinary Laparoscopy for Dogs
    Patil, H. R.
    Khandekar, G. S.
    Tripathi, S. D.
    Gaikwad, S. V.
    Sawant, R. L.
    Saini, Dishant
    Chauhan, S. A.
    INDIAN JOURNAL OF ANIMAL RESEARCH, 2025, 59 (02) : 349 - 353
  • [32] Reversal of adverse hemodynamic effects of pneumoperitoneum by pressure equilibration
    Bickel, A
    Arzomanov, T
    Ivry, S
    Zveibl, F
    Eitan, A
    ARCHIVES OF SURGERY, 2004, 139 (12) : 1320 - 1325
  • [33] HEMODYNAMIC-EFFECTS OF A PNEUMOPERITONEUM OF 4 HOURS DURING ISOFLURANE, DESFLURANE AND PROPOFOL ANESTHESIA IN PIGS
    BAZIN, JE
    GILLART, T
    VALLET, L
    WATTIEZ, A
    SCHOEFFLER, P
    ANESTHESIOLOGY, 1994, 81 (3A) : A664 - A664
  • [34] SONOGRAPHIC STUDY OF PNEUMOPERITONEUM TO AVOID INTESTINAL TROCAR INJURIES DURING LAPAROSCOPY
    SALMI, A
    LANZANI, G
    MASSIMO, G
    RANGONI, G
    VINCENZI, L
    GASTROINTESTINAL ENDOSCOPY, 1994, 40 (04) : 492 - 493
  • [35] Time-related changes in hemodynamic parameters and pressure-derived indices of left ventricular function in a porcine model of prolonged pneumoperitoneum
    I. G. Kaklamanos
    S. Condos
    R. C. Merrell
    Surgical Endoscopy, 2000, 14 : 834 - 838
  • [36] Time-related changes in hemodynamic parameters and pressure-derived indices of left ventricular function in a porcine model of prolonged pneumoperitoneum
    Kaklamanos, IG
    Condos, S
    Merrell, RC
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2000, 14 (09): : 834 - 838
  • [37] Hemodynamic effects of helium abdominal insufflation during laparoscopy in high-risk patients
    Dougherty, TB
    Fleming, RYD
    Feig, BW
    ANESTHESIA AND ANALGESIA, 1997, 84 : S153 - S153
  • [38] Portal and liver hemodynamic changes in rats during laparoscopy
    Schäfer, M
    Sägesser, H
    Reichen, J
    Krähenbühl, L
    JOURNAL OF HEPATOLOGY, 2000, 32 : 223 - 223
  • [39] A porcine model for renal hemodynamic study during laparoscopy
    Chiu, AW
    Chang, LS
    Birkett, DH
    Babayan, RK
    JOURNAL OF SURGICAL RESEARCH, 1996, 60 (01) : 61 - 68
  • [40] The Effects of Nasal High Flow on Hemodynamic Parameters During Sedation
    Ayuse, Takao
    Tatsuta, Erika
    Tatkov, Stanislav
    MIshima, Gaku
    ANESTHESIA AND ANALGESIA, 2024, 139 (06): : 88 - 89