Capsular capture of silicone intraocular lenses

被引:16
作者
Hayashi, K
Hayashi, H
Nakao, F
Hayashi, F
机构
[1] Hayashi Eye Hospital, Hakata-Ku, Fukuoka 812
关键词
D O I
10.1016/S0886-3350(96)80082-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To examine the incidence of capsular capture in silicone IOL implantation and determine its effect on visual acuity. Setting: Hayashi Eye Hospital, Fukuoka, Japan. Methods: This study comprised 144 eyes that had phacoemulsification with three-piece silicone intraocular lens (IOL) implantation that were evaluated about 3 months after surgery. The examination included the status of the haptic and optic placement, extent of posterior capsular opacification (PCO), and the best corrected visual acuity. Results: One hundred twenty-eight eyes had an in-in haptic placement, 15 had in-out placement, and 1 had out-out placement. Capsular capture occurred in 30 eyes (20.8%). The extent of PCO in eyes with capsular capture was greater than in those without capture. The best corrected visual acuity in eyes with capsular capture was worse than in those without capture. In addition, eyes with in-out and out-out haptic placement had significantly worse PCO and visual impairment than the eyes with in-in placement. Conclusion: There was a high incidence of capsular capture after silicone IOL implantation. This complication, along with the undesirable placement of the haptics, led to PCO and thus visual impairment.
引用
收藏
页码:1267 / 1271
页数:5
相关论文
共 17 条
  • [1] AYAKI M, 1990, J JPN OPHTHALMOL SOC, V94, P553
  • [2] KERATOMETRIC CYLINDER AND VISUAL PERFORMANCE FOLLOWING PHACOEMULSIFICATION AND IMPLANTATION WITH SILICONE SMALL-INCISION OR POLY(METHYL METHACRYLATE) INTRAOCULAR LENSES
    BRINT, SF
    OSTRICK, DM
    BRYAN, JE
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1991, 17 (01) : 32 - 36
  • [3] EVALUATION OF THE BIOCOMPATIBILITY AND FIXATION OF A NEW SILICONE INTRAOCULAR-LENS IN THE FELINE MODEL
    BUCHEN, SY
    RICHARDS, SC
    SOLOMON, KD
    APPLE, DJ
    KNIGHT, PM
    CHRIST, R
    PHAM, LT
    NELSON, DL
    CLAYMAN, HM
    KARPINSKI, LG
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (05) : 545 - 553
  • [4] CLINICAL AND PATHOLOGICAL EVALUATION OF A FLEXIBLE SILICONE POSTERIOR CHAMBER LENS DESIGN IN A RABBIT MODEL
    COOK, CS
    PEIFFER, RL
    MAZZOCCO, TR
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1986, 12 (02) : 130 - 134
  • [5] ANTERIOR CAPSULE OPACIFICATION IN MONKEY EYES WITH POSTERIOR CHAMBER INTRAOCULAR LENSES
    ISHIBASHI, T
    ARAKI, H
    SUGAI, S
    TAWARA, A
    OHNISHI, Y
    INOMATA, H
    [J]. ARCHIVES OF OPHTHALMOLOGY, 1993, 111 (12) : 1685 - 1690
  • [6] INHIBITION OF POSTERIOR CAPSULE OPACIFICATION - THE EFFECT OF COLCHICINE IN A SUSTAINED DRUG-DELIVERY SYSTEM
    LEGLER, UFC
    APPLE, DJ
    ASSIA, EI
    BLUESTEIN, EC
    CASTANEDA, VE
    MOWBRAY, SL
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1993, 19 (04) : 462 - 470
  • [7] MARTIN RG, 1992, OPHTHALMIC SURG LAS, V23, P770
  • [8] EFFECT OF SMALL INCISION INTRAOCULAR-LENS SURGERY ON POSTOPERATIVE INFLAMMATION AND ASTIGMATISM - A STUDY OF THE AMO SI-18NB SMALL INCISION LENS
    MARTIN, RG
    SANDERS, DR
    VANDERKARR, MA
    DELUCA, M
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (01) : 51 - 57
  • [9] MCDONNELL PJ, 1983, OPHTHALMOLOGY, V90, P1548
  • [10] EVALUATION OF THE 1ST 100 CONSECUTIVE PHACOFLEX SILICONE LENSES IMPLANTED IN THE BAG THROUGH A SELF-SEALING TUNNEL INCISION USING THE PRODIGY INSERTER
    MENAPACE, R
    AMON, M
    PAPAPANOS, P
    RADAX, U
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1994, 20 (03) : 299 - 309