Cone-Beam Computed Tomography: Accuracy of Three-dimensional Cephalometry Analysis and Influence of Patient Scanning Position

被引:15
作者
Frongia, Gianluigi [1 ]
Piancino, Maria Grazia [1 ]
Bracco, Pietro [1 ]
机构
[1] Univ Turin, Dept Orthodont & Gnathol Masticatory Funct, I-10126 Turin, Italy
关键词
CBCT; three-dimensional cephalometry; cephalometry software; head holder; cephalostat; HEAD FILM MEASUREMENTS; LANDMARK IDENTIFICATION; ORTHOGNATHIC SURGERY; RELIABILITY; CT; SUPERIMPOSITION; MULTISLICE; IMAGES;
D O I
10.1097/SCS.0b013e318252d5e1
中图分类号
R61 [外科手术学];
学科分类号
摘要
The aim of this research was to analyze the influence of the position of the skull during cone-beam computed tomography (CBCT) scan and if the three-dimensional cephalometric measurements are influenced by skull orientation during CBCT scan. The study consisted of 5 CBCT scanning (KODAK 9500 Cone Beam 3D System unit) in 5 different positions of a dry skull. The data were imported in SIMPLANT OMS Software version 13.0. Fifteen three-dimensional cephalometric measurements were calculated; moreover, the mean, the SD, the maximum/minimum Delta, and the maximum/minimum Delta percentage were calculated. The statistical analysis was performed by an independent-samples t-test to evaluate differences between the 5 scans. No difference was found in all the three-dimensional analysis. Twelve of 15 measurements have a Delta greater than 1.5, and 7 of 15 measurements have a Delta greater than 2. Nine of 15 have a Delta percentage greater than 5%. The preliminary results suggest that the three-dimensional cephalometric analysis is influenced by patient scanning position.
引用
收藏
页码:1038 / 1043
页数:6
相关论文
共 36 条
  • [1] Reliability and accuracy of cone-beam computed tomography dental measurements
    Baumgaertel, Sebastian
    Palomo, J. Martin
    Palomo, Leena
    Hans, Mark G.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 19 - 25
  • [2] RELIABILITY OF HEAD FILM MEASUREMENTS .1. LANDMARK IDENTIFICATION
    BAUMRIND, S
    FRANTZ, RC
    [J]. AMERICAN JOURNAL OF ORTHODONTICS, 1971, 60 (02): : 111 - &
  • [3] RELIABILITY OF HEAD FILM MEASUREMENTS .2. CONVENTIONAL ANGULAR AND LINEAR MEASURES
    BAUMRIND, S
    FRANTZ, RC
    [J]. AMERICAN JOURNAL OF ORTHODONTICS, 1971, 60 (05): : 505 - &
  • [4] Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull
    Berco, Mauricio
    Rigali, Paul H., Jr.
    Miner, R. Matthew
    DeLuca, Stephelynn
    Anderson, Nina K.
    Will, Leslie A.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 17.e1 - 17.e9
  • [5] Bracco P, 1984, MIN ORTOGNAT, V2, P147
  • [6] Broadbent Sr BH, 1975, BOLTON STANDARDS DEN, P1
  • [7] Superimposition of 3D cone-beam CT models of orthognathic surgery patients
    Cevidanes, LHS
    Bailey, LJ
    Tucker, GR
    Styner, MA
    Mol, A
    Phillips, CL
    Proffit, WR
    Turvey, T
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2005, 34 (06) : 369 - 375
  • [8] Head Orientation in CBCT-generated Cephalograms
    Cevidanes, Lucia
    Oliveira, Ana E. F.
    Motta, Alexandre
    Phillips, Ceib
    Burke, Brandon
    Tyndall, Donald
    [J]. ANGLE ORTHODONTIST, 2009, 79 (05) : 971 - 977
  • [9] Image analysis and superimposition of 3-dimensional cone-beam computed tomography models
    Cevidanes, Lucia H. S.
    Styner, Martin A.
    Proffit, William R.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2006, 129 (05) : 611 - 618
  • [10] Observer reliability of three-dimensional cephalometric landmark identification on cone-beam computerized tomography
    de Oliveira, Ana Emilia F.
    Cevidanes, Lucia Helena S.
    Phillips, Ceib
    Motta, Alexandre
    Burke, Brandon
    Tyndall, Donald
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 2009, 107 (02): : 256 - 265