Thermodynamic analysis of refrigerant mixtures for possible replacements for CFCs by an algorithm compiling property data

被引:14
作者
Arcaklioglu, E [1 ]
Çavusoglu, A
Erisen, A
机构
[1] Kirikkale Univ, Dept Mech Engn, Fac Engn, TR-71450 Yahsihan, Kirikkale, Turkey
[2] Gazi Univ, Tech Educ Fac, TR-06503 Besevler, Ankara, Turkey
关键词
refrigerant mixtures; CFC replacements; COP; REFPROP;
D O I
10.1016/j.applthermaleng.2005.06.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this study, we formed an algorithm to find refrigerant mixtures of equal volumetric cooling capacity (VCC) when compared to CFC based refrigerants in vapor compression refrigeration systems. To achieve this aim the point properties of the refrigerants are obtained from REFPROP where appropriate. We used replacement mixture ratios-of varying mass percentages-suggested by various authors along with our newly formed mixture ratios. In other words, we tried to see the effect of changing mass percentages of the suggested (i.e. in the literature) replacement refrigerants on the VCC of the cooling system. Secondly, we used this algorithm to calculate the coefficient of performance (COP) of the same refrigeration system. This mechanism has provided us the ability to compare the COP of the suggested refrigerant mixtures and our newly formed mixture ratios with the conventional CFC based ones. According to our results, for R12 R290/R600a (56/44) mixture, for R22 R32/R125/R134a (32.5/5/62.5) mixture, and for R502 R32/R125/R134a (43/5/52) mixture are appropriate and can be used as replacements. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:430 / 439
页数:10
相关论文
共 17 条
[1]   Behaviour and performances of R502 alternative working fluids in refrigerating plants [J].
Aprea, C ;
Mastrullo, R ;
deRossi, F .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1996, 19 (04) :257-263
[2]   A method for the prediction of vapour-liquid equilibria of refrigerant mixtures at low and moderate pressure [J].
Barolo, M ;
Bertucco, A ;
Scalabrin, G .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1995, 18 (08) :550-556
[3]   Experimental evaluation of refrigerant mixtures as substitutes for CFC12 and R502 [J].
Camporese, R ;
Bigolaro, G ;
Bobbo, S ;
Cortella, G .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1997, 20 (01) :22-31
[4]   ASSESSMENT OF HFCS, FLUORINATED ETHERS AND AMINE AS ALTERNATIVES TO CFC12 [J].
DEVOTTA, S ;
GOPICHAND, S ;
PENDYALA, VR .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1993, 16 (02) :84-90
[5]   Mixing rules for the specific heat capacities of several HFC-mixtures [J].
Gunther, D ;
Steimle, F .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1997, 20 (04) :235-243
[6]  
HOGBERG M, 1994, INT J REFRIG, V17, P417
[7]   Evaluation of supplementary/retrofit refrigerants for automobile air-conditioners charged with CFC12 [J].
Jung, D ;
Park, B ;
Lee, H .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (07) :558-568
[8]   A study on the performance of multi-stage heat pumps using mixtures [J].
Jung, DS ;
Kim, HJ ;
Kim, O .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1999, 22 (05) :402-413
[9]   PERFORMANCE SIMULATION OF SINGLE-EVAPORATOR DOMESTIC REFRIGERATORS CHARGED WITH PURE AND MIXED REFRIGERANTS [J].
JUNG, DS ;
RADERMACHER, R .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1991, 14 (04) :223-232
[10]   PERFORMANCE EVALUATION OF 2 AZEOTROPIC REFRIGERANT MIXTURES OF HFC-134A WITH R-290 (PROPANE) AND R-600A (ISOBUTANE) [J].
KIM, MS ;
MULROY, WJ ;
DIDION, DA .
JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 1994, 116 (02) :148-154