Experimental study on seismic performance of hybrid steel-polypropylene fiber-reinforced recycled aggregate concrete-filled circular steel tube columns

被引:24
作者
Zhao, Pengtuan [1 ]
Huang, Yue [1 ]
Liu, Zhenzhen [1 ]
Lu, Yiyan [1 ]
Wang, Han [1 ]
机构
[1] Wuhan Univ, Sch Civil Engn, Wuhan 430072, Peoples R China
关键词
Steel-polypropylene hybrid fiber; Recycled aggregate concrete filled square steel; tube; Hysteretic performance; Pseudo-static test; Restoring force model; HIGH-STRENGTH CONCRETE; EXPERIMENTAL BEHAVIOR; DEMOLISHED CONCRETE; SQUARE;
D O I
10.1016/j.conbuildmat.2022.129418
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, 1 recycled aggregate concrete-filled circular steel tube column (RACFST) and 11 hybrid steel -polypropylene fiber-reinforced recycled aggregate concrete-filled circular steel tube (HFRACFST) columns were designed given the variables of steel fiber (SF) volume content (Vsf = 0.6 %,1.2 %,1.8 %), polypropylene fiber (PPF) content fractions (Vpf = 0.05 %,0.10 %,0.15 %), concrete strengths (C40, C50, C60), thickness of steel tube (t = 2.70 mm, 3.65 mm, 4.50 mm), axial compression ratios (n = 0.25, 0.35, 0.45). Then the influence of variables on hysteretic curves, ductility, energy dissipation and stiffness degradation were studied experimen-tally using the pseudo-static tests. Subsequently, the restoring force models of HFRACFST were proposed based on the experimental results. The results indicated that: (1) The incorporation of HF (hybrid steel-polypropylene fiber) could enhance the hysteretic behaviour of HFRACFST columns. An increase in PPF content had little effect on the lateral bearing capacity and energy dissipation capability. Nevertheless, it could improve the ductility to some extent. As the SF content increased, the lateral bearing capacity, energy dissipation capability and ductility of the specimens increased. (2) An increase in concrete strength resulted in the increase of the bearing capacity and energy dissipation capability, but led to inferior ultimate deformation and ductility. (3) The comprehensive hysteretic behaviour was improved significantly as the thickness of steel tube increased, especially in the energy dissipation capability. (4) The specimens with higher axial compression ratio experienced inferior ultimate deformation and ductility. (5) The ductility indexes of all specimens were higher than 3.0. The yielding elastic and ultimate elastoplastic drift ratios were in the ranges 0.012-0.013 and 0.038-0.054, respectively. The hys-teretic performance of HFRACFST columns could satisfy the requirement of seismic design. It is feasible to apply the HFRACFST columns to vertical load-bearing structures in the seismic zones.
引用
收藏
页数:18
相关论文
共 62 条
[11]   Fatigue life analysis of polypropylene fiber reinforced concrete under axial constant-amplitude cyclic compression [J].
Cui, Kai ;
Xu, Lihua ;
Li, Xuefeng ;
Hu, Xuan ;
Huang, Le ;
Deng, Fangqian ;
Chi, Yin .
JOURNAL OF CLEANER PRODUCTION, 2021, 319
[12]   Creep and shrinkage of recycled aggregate concrete [J].
Domingo-Cabo, A. ;
Lazaro, C. ;
Lopez-Gayarre, F. ;
Serrano-Lopez, M. A. ;
Serna, P. ;
Castano-Tabares, J. O. .
CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (07) :2545-2553
[13]   Durability performance of concrete made with fine recycled concrete aggregates [J].
Evangelista, L. ;
de Brito, J. .
CEMENT & CONCRETE COMPOSITES, 2010, 32 (01) :9-14
[14]   Uniaxial compressive behavior of hook-end steel and macro-polypropylene hybrid fibers reinforced recycled aggregate concrete [J].
Feng, Junjie ;
Yin, Guansheng ;
Tuo, Hongliang ;
Wen, Congge ;
Liu, Zhu ;
Liang, Jianhong ;
Zhang, Yunjie .
CONSTRUCTION AND BUILDING MATERIALS, 2021, 304
[15]   Bond strength and prediction model for deformed bar embedded in hybrid fiber reinforced recycled aggregate concrete [J].
Gao, Danying ;
Yan, Huanhuan ;
Fang, Dong ;
Yang, Lin .
CONSTRUCTION AND BUILDING MATERIALS, 2020, 265
[16]   Influence Study of Reinforced Fiber on the Impact Resistance Performance of Recycled Aggregate Concrete [J].
Gao, Lin ;
Shi, Yan ;
Liu, Yachang .
MATERIALS PROCESSING TECHNOLOGY, PTS 1-3, 2012, 418-420 :250-+
[17]  
GB, 2015, GB 50010-2010
[18]  
GB, 2016, The Partial Revision of the National Standard 'Code for Seismic Design of Buildings' (2016 Edition) Passed the Examination
[19]  
GB/T, 2019, GB/T 50081-2019
[20]  
Guler S, 2014, ADV STEEL CONSTR, V10, P234