Real-time 3D echocardiographic transilluminated imaging combined with artificially intelligent left atrial appendage measurement for atrial fibrillation interventional procedures

被引:3
|
作者
Sun, Aijiao [1 ]
Ren, Sihua [2 ]
Xiao, Yangjie [1 ]
Chen, Yixin [1 ]
Wang, Nan [1 ]
Li, Chendi [1 ]
Tan, Xueying [1 ]
Pan, Yilong [3 ]
Sun, Feifei [1 ]
Ren, Weidong [1 ]
机构
[1] China Med Univ, Dept Ultrasound, Shengjing Hosp, Shenyang, Peoples R China
[2] China Med Univ, Dept Radiol, Affiliated Hosp 1, Shenyang, Peoples R China
[3] China Med Univ, Dept Cardiol, Shengjing Hosp, Shenyang, Peoples R China
基金
中国国家自然科学基金;
关键词
3D Auto LAA; artificial intelligence-AI; left atrial appendage occlusion; real-time three-dimensional; transesophageal echocardiography; TrueVue Glass; 3-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; CLOSURE; ANGIOGRAPHY; MORPHOLOGY;
D O I
10.3389/fphys.2022.1043551
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Aims: This study investigated the feasibility and accuracy of real-time three-dimensional (3D) echocardiographic transilluminated imaging (TrueVue Glass) in left atrial appendage (LAA) anatomical morphology and artificial intelligence (AI)-assisted 3D automated LAA measurement (3D Auto LAA) software in the preoperative evaluation of LAA occlusion (LAAO) in patients with atrial fibrillation (AF).Method and results: Thirty-seven patients with AF were selected. Two-dimensional (2D) and real-time 3D transesophageal echocardiography (RT3D-TEE) were performed preoperatively, using conventional 3D, the new 3D TrueVue Glass mode, and cardiac computed tomography angiography (CCTA) to assess and type the morphology of LAA. Physiological parameters were measured using traditional 2D and 3D manual (3D Manual LAA), 3D Auto LAA, and CCTA. TrueVue Glass for LAA outer contour display was compared with CCTA. Comparisons were based on correlation and consistency in measuring the maximum diameter (LZ max), minimum diameter (LZ min), area (LZ area), and circumference (LZ cir) of LAA landing zone (LZ). Times and variabilities were compared. The concordance rate for external shape of LAA was 97.14% between TrueVue Glass and CCTA. 3D Auto LAA and 3D Manual LAA have a stronger correlation and higher consistency in all parameters. 3D Auto LAA showed higher intra- and interobserver reproducibility and allowed quicker analysis (p < 0.05). LAAO was performed in 35 patients (94.59%), and none of which had serious adverse events.Conclusion: TrueVue Glass is the first non-invasive and radiation-free visualization of the overall external contour of LAA and its adjacent structures. 3D Auto LAA simplifies the measurement, making the preoperative assessment more efficient and convenient while ensuring the accuracy and reproducibility. A combination of the two is feasible for accurate and rapid assessment of LAA anatomy and physiology in AF patients and has practical application in LAAO.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] 3D Real-Time TEE During Pulmonary Vein Isolation in Atrial Fibrillation
    Acena, Marta
    Regoli, Francois
    Faletra, Francesco Fulvio
    Tritto, Massimo
    Klersy, Catherine
    Murzilli, Romina
    Scopigni, Francesca
    Penco, Maria
    Pasotti, Elena
    Moccetti, Tiziano
    Auricchio, Angelo
    JACC-CARDIOVASCULAR IMAGING, 2014, 7 (07) : 737 - 738
  • [22] Left Atrial Appendage Thrombus and Real-Time 3-Dimensional Transesophageal Echocardiography
    Matyal, Robina
    Mahmood, Faraz
    Chaudhry, Hashim
    Cummisford, Kevin
    Hagberg, Robert
    Mahmood, Feroze
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2010, 24 (06) : 977 - 979
  • [23] Evaluation of the Left Atrial Appendage With Real-Time 3-Dimensional Transesophageal Echocardiography Implications for Catheter-Based Left Atrial Appendage Closure
    Nucifora, Gaetano
    Faletra, Francesco F.
    Regoli, Francois
    Pasotti, Elena
    Pedrazzini, Giovanni
    Moccetti, Tiziano
    Auricchio, Angelo
    CIRCULATION-CARDIOVASCULAR IMAGING, 2011, 4 (05) : 514 - 523
  • [24] A comparison of two-dimensional and real-time 3D transoesophageal echocardiography and angiography for assessing the left atrial appendage anatomy for sizing a left atrial appendage occlusion system: impact of volume loading
    Al-Kassou, Baravan
    Tzikas, Apostolos
    Stock, Friederike
    Neikes, Fabian
    Voelz, Alexander
    Omran, Heyder
    EUROINTERVENTION, 2017, 12 (17) : 2083 - 2091
  • [25] Measurement of left and right atrial volume in patients undergoing ablation for atrial arrhythmias: comparison of different algorithms of real-time 3D echocardiography
    Mueller, H.
    Reverdin, S.
    Burri, H.
    Shah, D.
    Lerch, R.
    EUROPEAN HEART JOURNAL, 2012, 33 : 853 - 853
  • [26] Real-time echocardiography-fluoroscopy fusion imaging for left atrial appendage closure: prime time for fusion imaging?
    Afzal, Shazia
    Piayda, Kerstin
    Hellhammer, Katharina
    Veulemans, Verena
    Wolff, Georg
    Heidari, Houtan
    Stuewe, Dominique
    Kanschik, Dominika
    Polzin, Amin
    Kelm, Malte
    Zeus, Tobias
    ACTA CARDIOLOGICA, 2021, 76 (09) : 1004 - 1012
  • [27] Relationship between left atrial and left ventricular function in hypertrophic carcliomyopathy: A real time 3D echocardiographic study
    Shin, MS
    Fukuda, S
    Song, JM
    Daimon, M
    Tran, H
    Thomas, JD
    Shiola, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 50A - 51A
  • [28] Interventional left atrial appendage occlusion: added value of 3D transesophageal echocardiography for device sizing
    Björn Goebel
    Stephanie Wieg
    Ali Hamadanchi
    Sylvia Otto
    Christian Jung
    Daniel Kretzschmar
    Hans R. Figulla
    P. Christian Schulze
    Tudor C. Poerner
    The International Journal of Cardiovascular Imaging, 2016, 32 : 1363 - 1370
  • [29] Interventional left atrial appendage occlusion: added value of 3D transesophageal echocardiography for device sizing
    Goebel, Bjoern
    Wieg, Stephanie
    Hamadanchi, Ali
    Otto, Sylvia
    Jung, Christian
    Kretzschmar, Daniel
    Figulla, Hans R.
    Schulze, P. Christian
    Poerner, Tudor C.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2016, 32 (09): : 1363 - 1370
  • [30] Interventional left atrial appendage occlusion: Added value of 3D transesophageal echocardiography for orifice sizing
    Goebel, B.
    Wieg, S.
    Hamadanchi, A.
    Otto, S.
    Kretzschmar, D.
    Jung, C.
    Figulla, H. R.
    Poerner, T. C.
    EUROPEAN HEART JOURNAL, 2014, 35 : 40 - 40