Real-time 3D echocardiographic transilluminated imaging combined with artificially intelligent left atrial appendage measurement for atrial fibrillation interventional procedures

被引:3
|
作者
Sun, Aijiao [1 ]
Ren, Sihua [2 ]
Xiao, Yangjie [1 ]
Chen, Yixin [1 ]
Wang, Nan [1 ]
Li, Chendi [1 ]
Tan, Xueying [1 ]
Pan, Yilong [3 ]
Sun, Feifei [1 ]
Ren, Weidong [1 ]
机构
[1] China Med Univ, Dept Ultrasound, Shengjing Hosp, Shenyang, Peoples R China
[2] China Med Univ, Dept Radiol, Affiliated Hosp 1, Shenyang, Peoples R China
[3] China Med Univ, Dept Cardiol, Shengjing Hosp, Shenyang, Peoples R China
基金
中国国家自然科学基金;
关键词
3D Auto LAA; artificial intelligence-AI; left atrial appendage occlusion; real-time three-dimensional; transesophageal echocardiography; TrueVue Glass; 3-DIMENSIONAL TRANSESOPHAGEAL ECHOCARDIOGRAPHY; COMPUTED-TOMOGRAPHY; CLOSURE; ANGIOGRAPHY; MORPHOLOGY;
D O I
10.3389/fphys.2022.1043551
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Aims: This study investigated the feasibility and accuracy of real-time three-dimensional (3D) echocardiographic transilluminated imaging (TrueVue Glass) in left atrial appendage (LAA) anatomical morphology and artificial intelligence (AI)-assisted 3D automated LAA measurement (3D Auto LAA) software in the preoperative evaluation of LAA occlusion (LAAO) in patients with atrial fibrillation (AF).Method and results: Thirty-seven patients with AF were selected. Two-dimensional (2D) and real-time 3D transesophageal echocardiography (RT3D-TEE) were performed preoperatively, using conventional 3D, the new 3D TrueVue Glass mode, and cardiac computed tomography angiography (CCTA) to assess and type the morphology of LAA. Physiological parameters were measured using traditional 2D and 3D manual (3D Manual LAA), 3D Auto LAA, and CCTA. TrueVue Glass for LAA outer contour display was compared with CCTA. Comparisons were based on correlation and consistency in measuring the maximum diameter (LZ max), minimum diameter (LZ min), area (LZ area), and circumference (LZ cir) of LAA landing zone (LZ). Times and variabilities were compared. The concordance rate for external shape of LAA was 97.14% between TrueVue Glass and CCTA. 3D Auto LAA and 3D Manual LAA have a stronger correlation and higher consistency in all parameters. 3D Auto LAA showed higher intra- and interobserver reproducibility and allowed quicker analysis (p < 0.05). LAAO was performed in 35 patients (94.59%), and none of which had serious adverse events.Conclusion: TrueVue Glass is the first non-invasive and radiation-free visualization of the overall external contour of LAA and its adjacent structures. 3D Auto LAA simplifies the measurement, making the preoperative assessment more efficient and convenient while ensuring the accuracy and reproducibility. A combination of the two is feasible for accurate and rapid assessment of LAA anatomy and physiology in AF patients and has practical application in LAAO.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] 3D Real-Time Intracardiac Echocardiographic Visualization of Atrial Structures Relevant to Atrial Fibrillation Ablation
    Brysiewicz, Neil
    Mitiku, Teferi
    Haleem, Kamran
    Bhatt, Paras
    Al-Shaaraoui, Mustapha
    Clancy, Jude F.
    Marieb, Mark A.
    Sugeng, Lissa
    Akar, Joseph G.
    JACC-CARDIOVASCULAR IMAGING, 2014, 7 (01) : 97 - 100
  • [2] Left atrial volume measurement by real-time 3D echocardiography
    Bauer, F
    Shiota, T
    White, R
    Oin, JX
    Travaglini, A
    Tsujino, H
    Thomas, JD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 437A - 437A
  • [3] The Value of 3D Printing Models of Left Atrial Appendage Using Real-Time 3D Transesophageal Echocardiographic Data in Left Atrial Appendage Occlusion: Applications toward an Era of Truly Personalized Medicine
    Liu, Peng
    Liu, Rijing
    Zhang, Yan
    Liu, Yingfeng
    Tang, Xiaoming
    Cheng, Yanzhen
    CARDIOLOGY, 2016, 135 (04) : 255 - 261
  • [4] 3D transesophageal echocardiographic reconstruction of the left atrial appendage:: Experimental results and first human experiences with an interventional closing device of the left atrial appendage (PLAATO)
    Omran, H
    Hardung, D
    Lesh, M
    Schmidt, H
    von der Recke, G
    Hammerstingl, C
    Lewalter, T
    Kuntz-Hehner, S
    Lüderitz, B
    CIRCULATION, 2002, 106 (19) : 705 - 705
  • [5] Application value of real-time 3D speckle tracking imaging in left atrial function evaluation of patients with paroxysmal atrial fibrillation
    Wang, Yufeng
    Bai, Dong
    Lu, Xiaojun
    Hou, Haijun
    Liang, Lei
    MEDICINE, 2024, 103 (21) : E38206
  • [6] First experience with real-time 3D anatomical fusion imaging during left atrial appendage occluder implantation
    Afzal, Shazia
    Soetemann, Dagmar
    Nijhof, Niels
    Kelm, Malte
    Zeus, Tobias
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (06) : 719 - 720
  • [7] Evaluation of left atrial appendage function and thrombi in patients with atrial fibrillation: from transthoracic to real time 3D transesophageal echocardiography
    Dentamaro, Ilaria
    Vestito, Domenico
    Michelotto, Ennio
    De Santis, Delia
    Ostuni, Vittoria
    Cadeddu, Christian
    Colonna, Paolo
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (04): : 491 - 498
  • [8] Evaluation of left atrial appendage function and thrombi in patients with atrial fibrillation: from transthoracic to real time 3D transesophageal echocardiography
    Ilaria Dentamaro
    Domenico Vestito
    Ennio Michelotto
    Delia De Santis
    Vittoria Ostuni
    Christian Cadeddu
    Paolo Colonna
    The International Journal of Cardiovascular Imaging, 2017, 33 : 491 - 498
  • [9] Real-Time 3D Echocardiographic Quantification of Left Atrial Volume: Multicenter Study for Validation with Magnetic Resonance Imaging
    Mor-Avi, Victor
    Yodwut, Chattanong
    Jenkins, Carly
    Kuhl, Harald
    Nesser, Hans-Joachim
    Marwick, Thomas H.
    Franke, Andreas
    Niel, Johannes
    Steringer-Mascherbauer, Regina
    Sugeng, Lissa
    Lang, Roberto M.
    CIRCULATION, 2011, 124 (21)
  • [10] Real-time 3D transesophageal echocardiography assisted the percutaneous transcatheter left atrial appendage closure
    Cheng, H. -L
    Chou, W. -H
    Wang, Y-C
    Huang, C. -H
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2014, 31 : 74 - 75