Effect of trypan blue on the elasticity of the human anterior lens capsule

被引:51
作者
Dick, H. Burkhard [1 ]
Aliyeva, Shakhsanarn E. [2 ]
Hengerer, Fritz [3 ]
机构
[1] Ruhr Univ Bochum, Hosp Eye, Ctr Vis Sci, Dept Ophthalmol, D-44892 Bochum, Germany
[2] Johannes Gutenberg Univ Mainz, Dept Ophthalmol, Mainz, Germany
[3] Germany Ctr Vis Sci, Bochum, Germany
关键词
D O I
10.1016/j.jcrs.2008.03.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the effect of trypan blue (VisionBlue) staining on the elastic properties of the human anterior lens capsule. SETTING: Center for Vision Science, Ruhr University Eye Hospital, Bochum, Germany. METHODS: Nineteen anterior capsules were obtained from 19 human eyes at the time of cataract operation. Two same-size strips were prepared from each capsule; 1 was exposed to trypan blue staining for 10 seconds, and the other was a control. The elasticity measurements were performed on both specimens using a modified rheometer. RESULTS: The mean age of the patients was 75.3 years +/- 13.3 (SD) (range 35 to 89 years). Sixty-three measurements of 19 suitable specimen pairs were performed. In 13 pairs, the elasticity measurements were eligible for statistical analysis. The stress value at the tearing point was statistically significantly lower in the treated group (mean 169 +/- 55 Pa) than in the control group without staining (mean 252 +/- 67 Pa) (P=.023). The difference in stress between the stained and control samples at 3 seconds and 5 seconds was not statistically significant (P=.093 versus P=.316). Dynamic frequency sweep measurements showed a statistically significant elevation of the viscosity modulus in the samples stained with trypan blue. CONCLUSIONS: Trypan blue staining affected the biomechanical properties of the human lens capsule and led to a significant reduction in elasticity and an increase in stiffness. These results confirm clinical reports of changes in the capsule by dye and should be taken into consideration in dye-enhanced cataract surgery.
引用
收藏
页码:1367 / 1373
页数:7
相关论文
共 50 条
[41]   Trypan blue dye for anterior segment surgeries [J].
V Jhanji ;
E Chan ;
S Das ;
H Zhang ;
R B Vajpayee .
Eye, 2011, 25 :1113-1120
[42]   A SAFE, NON-INVASIVE TECHNIQUE FOR ELIMINATION OF ANTERIOR CHAMBER TRYPAN BLUE USED FOR ANTERIOR CAPSULE STAINING IN CATARACT SURGERY [J].
Ewe, Shaun Y. P. ;
Shah, Saumil A. ;
Agar, Ashish ;
Francis, Ian C. .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2015, 43 :74-75
[43]   Anterior lens capsule as a tool to study the physiology of human lens epithelial cells [J].
Andjelic, Sofija ;
Zupancic, Gregor ;
Perovsek, Darko ;
Robic, Tatjana ;
Hawlina, Marko .
ZDRAVNISKI VESTNIK-SLOVENIAN MEDICAL JOURNAL, 2010, 79 :123-130
[44]   Effect of intraocular lens and anterior capsule opening type on posterior capsule opacification [J].
Birinci, H ;
Kuruoglu, S ;
Öge, I ;
Öge, F ;
Acar, E .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1999, 25 (08) :1140-1146
[45]   Trypan blue staining for capsulorhexis: Ultrastructural effect on lens epithelial cells and capsules [J].
Portes, Andre Luis F. ;
Almeida, Andrea C. ;
Allodi, Silvana ;
Monteiro, Mario L. R. ;
Miguel, Nadia C. O. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2010, 36 (04) :582-587
[46]   Effects of trypan blue on corneal endothelium and anterior lens capsule in albino Wistar rats:: An investigator-masked, controlled, two-period, experimental study [J].
Ari, Seyhmus ;
Caca, Ihsan ;
Unlu, Kaan ;
Nergiz, Yusuf ;
Aksit, Ihsan .
CURRENT THERAPEUTIC RESEARCH-CLINICAL AND EXPERIMENTAL, 2006, 67 (06) :366-377
[47]   Time course of lens capsule staining using trypan blue and indocyanine green - In vitro study in porcine eyes [J].
Satofuka, S ;
Nakamura, K ;
Negishi, K ;
Kato, K ;
Kurosaka, D ;
Yoshino, M .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (08) :1751-1754
[48]   Presumed interference colours at the level of the human anterior lens capsule [J].
Yasuyuki Nakashima ;
Fumiaki Yoshitomi ;
Shiro Amano ;
Tetsuro Oshika .
Eye, 2001, 15 :206-208
[49]   Biomechanical characteristics of the human anterior lens capsule in relation to age [J].
Krag, S ;
Olsen, T ;
Andreassen, TT .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (02) :357-363
[50]   Presumed interference colours at the level of the human anterior lens capsule [J].
Nakashima, Y ;
Yoshitomi, F ;
Amano, S ;
Oshika, T .
EYE, 2001, 15 (2) :206-208