Effect of trypan blue on the elasticity of the human anterior lens capsule

被引:51
|
作者
Dick, H. Burkhard [1 ]
Aliyeva, Shakhsanarn E. [2 ]
Hengerer, Fritz [3 ]
机构
[1] Ruhr Univ Bochum, Hosp Eye, Ctr Vis Sci, Dept Ophthalmol, D-44892 Bochum, Germany
[2] Johannes Gutenberg Univ Mainz, Dept Ophthalmol, Mainz, Germany
[3] Germany Ctr Vis Sci, Bochum, Germany
来源
JOURNAL OF CATARACT AND REFRACTIVE SURGERY | 2008年 / 34卷 / 08期
关键词
D O I
10.1016/j.jcrs.2008.03.041
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To evaluate the effect of trypan blue (VisionBlue) staining on the elastic properties of the human anterior lens capsule. SETTING: Center for Vision Science, Ruhr University Eye Hospital, Bochum, Germany. METHODS: Nineteen anterior capsules were obtained from 19 human eyes at the time of cataract operation. Two same-size strips were prepared from each capsule; 1 was exposed to trypan blue staining for 10 seconds, and the other was a control. The elasticity measurements were performed on both specimens using a modified rheometer. RESULTS: The mean age of the patients was 75.3 years +/- 13.3 (SD) (range 35 to 89 years). Sixty-three measurements of 19 suitable specimen pairs were performed. In 13 pairs, the elasticity measurements were eligible for statistical analysis. The stress value at the tearing point was statistically significantly lower in the treated group (mean 169 +/- 55 Pa) than in the control group without staining (mean 252 +/- 67 Pa) (P=.023). The difference in stress between the stained and control samples at 3 seconds and 5 seconds was not statistically significant (P=.093 versus P=.316). Dynamic frequency sweep measurements showed a statistically significant elevation of the viscosity modulus in the samples stained with trypan blue. CONCLUSIONS: Trypan blue staining affected the biomechanical properties of the human lens capsule and led to a significant reduction in elasticity and an increase in stiffness. These results confirm clinical reports of changes in the capsule by dye and should be taken into consideration in dye-enhanced cataract surgery.
引用
收藏
页码:1367 / 1373
页数:7
相关论文
共 50 条
  • [1] Biomechanical changes in the anterior lens capsule after trypan blue staining
    Wollensak, G
    Spörl, E
    Pham, DT
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (07): : 1526 - 1530
  • [2] Trypan blue vital staining of the anterior lens capsule in the management of cataract in true exfoliation of the lens capsule
    J Rossiter
    A Morris
    Eye, 2005, 19 : 809 - 810
  • [3] Trypan blue vital staining of the anterior lens capsule in the management of cataract in true exfoliation of the lens capsule
    Rossiter, J
    Morris, A
    EYE, 2005, 19 (07) : 809 - 810
  • [4] Anterior lens capsule has more affinity to trypan blue in patients with pseudoexfoliation
    Hosseini, H.
    Nowroozzadeh, M. H.
    Razeghinejad, M. R.
    Ashraf, H.
    Salouti, R.
    Ashraf, M. J.
    EYE, 2011, 25 (09) : 1245 - 1246
  • [5] Anterior lens capsule has more affinity to trypan blue in patients with pseudoexfoliation
    H Hosseini
    M H Nowroozzadeh
    M R Razeghinejad
    H Ashraf
    R Salouti
    M J Ashraf
    Eye, 2011, 25 : 1245 - 1246
  • [6] Trypan Blue as a Surgical Adjunct to Decrease Lens Capsule Elasticity in Pediatric Cataract Surgery
    Rizzuti, Allison E.
    Fridman, Gabrielle
    Rolain, Mark
    Kaufman, Stephen C.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [7] Crystalline lens capsule staining with trypan blue
    San Laureano, J
    Coroneo, MT
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (10): : 2046 - 2049
  • [8] Three-step technique for staining the anterior lens capsule with indocyanine green or trypan blue
    Marques, DMV
    Marques, FF
    Osher, RH
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2004, 30 (01): : 13 - 16
  • [9] Staining of anterior lens capsule with Trypan blue for better visualization of capsulorhexis in surgery of mature cataracts
    Melles, GRJ
    de Waard, PWT
    Pameijer, JH
    Beekhuis, WH
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1999, 215 (06) : 342 - 344
  • [10] Evaluation of mechanical resistance to tearing of the anterior lens capsule after staining with different concentrations of trypan blue
    Sandor, Gabor L.
    Kiss, Zoltan
    Bocskai, Zoltan I.
    Toth, Gabor
    Temesi, Tamas
    Nagy, Zoltan Z.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (02): : 293 - 297