The concept of personalized ventilation (PV) is at the cutting edge of technological development in the area of air conditioning and is fundamentally aimed at improving ventilation in the immediate breathing zones of occupants in the built environment. While the current state-of-the-art PV systems make this possible for seated individuals within the occupied zone, it is envisaged that flexible PV systems, extending the range of application within the dynamic movements of individuals in an air-conditioned zone, may be a reality in the near future. The ability of P V systems to enhance thermal comfort and indoor air quality (IAQ) and the energy savings that would result were examined under the hot and humid tropical conditions of Singapore. The experimental design consisted of 17 different environmental conditions, characterized by a combination of room ambient temperature (23 degrees C and 26 degrees C), PV air temperature (20 degrees C, 23 degrees C, and 26 degrees C), and the PV airflow rate (7, 11, and 15 L/s per person). The experimental design also included a reference condition with the primary background air-conditioning system operating under the same conditions but without PV air. Eleven human subjects took part in all the experiments, and a detailed questionnaire was employed to solicit their subjective responses during each exposure. Air velocity, air temperature, and ventilation effectiveness were measured in the immediate breathing zone of each occupant. The results indicate that the use of a secondary PV system in conjunction with a primary air-conditioning system not only enhances thermal comfort and IAQ acceptability but can reduce energy consumption by 15-30%. PV systems can improve ventilation effectiveness at the immediate breathing zone by up to 50% more than can be obtained with mixing ventilation (MV) alone, and P V tends to lower the average temperature of inhaled air in the breathing zone by 2-5 degrees C, enhancing perceived air quality. PV temperature and PV flow rate were found to be more critical than ambient temperature for occupants' thermal comfort and the perceived air quality of inhaled air.
引用
收藏
页码:603 / 620
页数:18
相关论文
共 50 条
  • [1] Ceiling mounted personalized ventilation system in hot and humid climate-An energy analysis
    Yang, Bin
    Sekhar, Chandra
    Melikov, Arsen K.
    ENERGY AND BUILDINGS, 2010, 42 (12) : 2304 - 2308
  • [2] Energy analysis of the personalized ventilation system in hot and humid climates
    Schiavon, Stefano
    Melikov, Arsen K.
    Sekhar, Chandra
    ENERGY AND BUILDINGS, 2010, 42 (05) : 699 - 707
  • [3] Experimental and simulated energy performance of a personalized ventilation system with individual airflow control in a hot and humid climate
    Chen, Yixing
    Raphael, Benny
    Sekhar, S. C.
    BUILDING AND ENVIRONMENT, 2016, 96 : 283 - 292
  • [4] Thermal comfort and IAQ assessment of under-floor air distribution system integrated with personalized ventilation in hot and humid climate
    Li, Ruixin
    Sekhar, S. C.
    Melikov, A. K.
    BUILDING AND ENVIRONMENT, 2010, 45 (09) : 1906 - 1913
  • [5] Effectiveness of Stack Ventilation in a Two-Storey House in Hot and Humid Climate
    Chindavanig, Thanit
    3RD WORLD MULTIDISCIPLINARY CIVIL ENGINEERING, ARCHITECTURE, URBAN PLANNING SYMPOSIUM (WMCAUS 2018), 2019, 471
  • [6] Study of an integrated personalized ventilation and local fan-induced active chilled beam air conditioning system in hot and humid climate
    Sekhar, Chandra
    Zheng, Long
    BUILDING SIMULATION, 2018, 11 (04) : 787 - 801
  • [7] Ceiling-mounted personalized ventilation system integrated with a secondary air distribution system - a human response study in hot and humid climate
    Yang, B.
    Sekhar, S. C.
    Melikov, A. K.
    INDOOR AIR, 2010, 20 (04) : 309 - 319
  • [8] Study of an integrated personalized ventilation and local fan-induced active chilled beam air conditioning system in hot and humid climate
    Chandra Sekhar
    Long Zheng
    Building Simulation, 2018, 11 : 787 - 801
  • [9] The effectiveness of night ventilation technique for residential buildings in hot-humid climate of Malaysia
    Kubota, Tetsu
    Hooi Chyee, Doris Toe
    Journal of Environmental Engineering, 2009, 74 (635) : 89 - 95
  • [10] Direct solar regenerated desiccant dehumidification system for sustainable ventilation in hot and humid climate
    Sleiman, Sleiman
    Harrouz, Jean Paul
    Ghali, Kamel
    Ghaddar, Nesreen
    ENERGY CONVERSION AND MANAGEMENT, 2024, 301