An ultrasensitive electrochemical immunosensor for the detection of salbutamol based on Pd@SBA-15 and ionic liquid

被引:38
作者
Cui, Zhentao [1 ]
Cai, Yanyan [1 ]
Wu, Dan [1 ]
Yu, Haiqin [1 ]
Li, Yan [1 ]
Mao, Kexia [1 ]
Wang, Huan [1 ]
Fan, Haixia [1 ]
Wei, Qin [1 ]
Du, Bin [1 ]
机构
[1] Univ Jinan, Sch Chem & Chem Engn, Shandong Univ, Key Lab Chem Sensing & Anal, Jinan 250022, Peoples R China
关键词
Sandwich-type immunosensor; Salbutamol antigen; Graphene sheets; Pd@SBA-15; Ionic liquid; AMPEROMETRIC GLUCOSE BIOSENSOR; MESOPOROUS SILICA; AQUEOUS DISPERSIONS; MODIFIED ELECTRODE; GRAPHENE; IMMOBILIZATION; HEMOGLOBIN; ENCAPSULATION; SBA-15; ELECTROCATALYSIS;
D O I
10.1016/j.electacta.2012.02.073
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A sandwich-type electrochemical immunosensor for the ultrasensitive detection of the salbutamol (SAL) antigen based on sodium dodecylbenzene sulfonate-functionalized graphene sheets (SDBS-GS), Pd nanoparticles in functionalizecl SBA-15 (Pd@SBA-15) and ionic liquid (IL) is described. The primary SAL antibody (Ab(1)) can be covalently attached to the sulfonic groups of SOBS-GS through the amines of Ab(1) with an acyl chloride cross-linking reaction. Pd@SBA-15 was prepared by adsorption of H2PdCl4 onto the SBA-15 surface; the adsorbed H2PdCl4 was then reduced to Pd nanoparticles with sodium borohydride. Pd@SBA-15 was conjugated to the secondary SAL antibody (Ab(2)) through glutaraldehyde. IL was added to the mixture of Pd@SBA-15 and Ab(2) to promote electron transport. The synergistic effect between IL and Pd@SBA-15 retained the bioactivity of Ab(2). The sensitivity of the sandwich-type immunosensor using Pd@SBA-15/Ab(2)/IL for the detection of SAL was much higher than those that used either SBA-15/Ab(2) or Pd@SBA-15/Ab(2). Under optimal conditions, the electrochemical immunosensor exhibited a wide working range from 0.02 to 15.0 ng/mL with a detection limit of 7 pg/mL. The precision, reproducibility and stability of the immunosensor were acceptable. The proposed strategy could be easily extended to fabricate immunosensors for other tumor markers. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:79 / 85
页数:7
相关论文
共 42 条
[1]   Highly Active PdPt Catalysts for the Electrochemical Reduction of H2O2 [J].
Adams, Brian D. ;
Ostrom, Cassandra K. ;
Chen, Aicheng .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2011, 158 (04) :B434-B439
[2]   Gold nanoparticles-mesoporous silica composite used as an enzyme immobilization matrix for amperometric glucose biosensor construction [J].
Bai, Yu ;
Yang, Hua ;
Yang, Weiwei ;
Li, Yancai ;
Sun, Changqing .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 124 (01) :179-186
[3]   THE DETERMINATION OF PORE VOLUME AND AREA DISTRIBUTIONS IN POROUS SUBSTANCES .1. COMPUTATIONS FROM NITROGEN ISOTHERMS [J].
BARRETT, EP ;
JOYNER, LG ;
HALENDA, PP .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1951, 73 (01) :373-380
[4]   Towards the development of a portable sensor based on a molecularly imprinted membrane for the rapid determination of salbutamol in pig urine [J].
Chai, Chunyan ;
Liu, Guoyan ;
Li, Feng ;
Liu, Xiaofang ;
Yao, Bing ;
Wang, Li .
ANALYTICA CHIMICA ACTA, 2010, 675 (02) :185-190
[5]   Electrochemical Biosensor for Detection of BCR/ABL Fusion Gene Using Locked Nucleic Acids on 4-Aminobenzenesulfonic Acid-Modified Glassy Carbon Electrode [J].
Chen, Jinghua ;
Zhang, Jing ;
Wang, Kun ;
Lin, Xinhua ;
Huang, Liying ;
Chen, Guonan .
ANALYTICAL CHEMISTRY, 2008, 80 (21) :8028-8034
[6]   Effects of pH and pore characters of mesoporous silicas on horseradish peroxidase immobilization [J].
Chouyyok, Wilaiwan ;
Panpranot, Joongjai ;
Thanachayanant, Chanchana ;
Prichanont, Seeroong .
JOURNAL OF MOLECULAR CATALYSIS B-ENZYMATIC, 2009, 56 (04) :246-252
[7]   A new amperometric glucose biosensor based on platinum nanoparticles/polymerized ionic liquid-carbon nanotubes nanocomposites [J].
Chu, Xiaochen ;
Wu, Bohua ;
Xiao, Chunhui ;
Zhang, Xiaohua ;
Chen, Jinhua .
ELECTROCHIMICA ACTA, 2010, 55 (08) :2848-2852
[8]  
El-Enany N., 2004, CHEM ANAL WARSAW POL, V49, P587
[9]   Fast determination of salbutamol, abused by athletes for doping, in pharmaceuticals and human biological fluids by square wave voltammetry [J].
Goyal, Rajendra N. ;
Oyama, Munetaka ;
Singh, Sudhanshu P. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 611 (1-2) :140-148
[10]  
Habib I. H. I., 2005, Farmaco (Lausanne), V60, P249, DOI 10.1016/j.farmac.2004.11.007