Time-resolved contrast-enhanced three-dimensional pulmonary MR-angiography:: 1.0 M gadobutrol vs. 0.5 M gadopentetate dimeglumine

被引:28
作者
Fink, C
Bock, M
Kiessling, F
Lichy, MP
Krissak, R
Zuna, I
Schmähl, A
Delorme, S
Kauczor, HU
机构
[1] Deutsch Krebsforschungszentrum, Dept Radiol, D-69120 Heidelberg, Germany
[2] Deutsch Krebsforschungszentrum, Dept Med Phys Radiol, D-69120 Heidelberg, Germany
[3] Deutsch Krebsforschungszentrum, Clin Cooperat Unit Radiotherapeut Oncol, D-69120 Heidelberg, Germany
[4] Thoraxklin, Dept Radiol, Heidelberg, Germany
关键词
lung; magnetic resonance angiography; comparative study; contrast agent; time-resolved;
D O I
10.1002/jmri.10452
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare contrast characteristics and image quality of 1.0 M gadobutrol with 0.5 M Gd-DTPA for time-resolved three-dimensional pulmonary magnetic resonance angiography (MRA). Materials and Methods: Thirty-one patients and five healthy volunteers were examined with a contrast-enhanced time-resolved pulmonary MRA protocol (fast low-angle shot [FLASH] three-dimensional, TR/TE=2.2/1.0 msec, flip angle: 25degrees, scan time per three-dimensional data set=5.6 seconds). Patients were randomized to receive either 0.1 mmol/kg body weight (bw) or 0.2 mmol/kg bw gadobutrol, or 0.2 mmol/kg bw Gd-DTPA. Volunteers were examined three times, twice with 0.2 mmol/kg bw gadobutrol. using two different flip angles and once with 0.2 mmol/kg bw Gd-DTPA. All contrast injections were performed at a rate of 5 mL/second. Image analysis included signal-to-noise ratio (SNR) and contrast-to-noise. ratio (CNR) measurements in lung arteries and veins, as well as a subjective analysis of image quality. Results: In patients, significantly higher SNR and CNR were observed with Gd-DTPA compared to both doses of gadobutrol (SNR: 35-42 vs. 17-25; CNR 33-39 vs. 16-23; Pless than or equal to0.05). No relevant differences were observed between 0.1 mmol/kg bw and 0.2 mmol/kg bw gadobutrol. In volunteers, gadobutrol and Gd-DTPA achieved similar SNR and CNR. A significantly higher SNR and CNR was observed for gadobutrol-enhanced MRA with an increased flip angle of 40degrees. Image quality was rated equal for both contrast agents. Conclusion: No relevant advantages of 1.0 M gadobutrol over 0.5 M Gd-DTPA were observed for time-resolved pulmonary MRA in this study. Potential explanations are T2/T2*-effects caused by the high intravascular concentration when using high injection rates.
引用
收藏
页码:202 / 208
页数:7
相关论文
共 27 条
[11]   Time-resolved contrast-enhanced 3D MR angiography [J].
Korosec, FR ;
Frayne, R ;
Grist, TM ;
Mistretta, CA .
MAGNETIC RESONANCE IN MEDICINE, 1996, 36 (03) :345-351
[12]  
Meaney JFM, 1999, JMRI-J MAGN RESON IM, V10, P326, DOI 10.1002/(SICI)1522-2586(199909)10:3<326::AID-JMRI15>3.3.CO
[13]  
2-C
[14]   Morphologic and functional assessment of vascular abnormalities of the pulmonary vasculature by breath-hold MR techniques [J].
Mohrs, OK ;
Voigtländer, T ;
Heussel, CP ;
Von Bardeleben, S ;
Düber, C ;
Kreitner, KF .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (04) :467-473
[15]   Time-resolved contrast-enhanced pulmonary MR angiography using sensitivity encoding (SENSE) [J].
Ohno, Y ;
Kawamitsu, H ;
Higashino, T ;
Takenaka, D ;
Watanabe, H ;
van Cauteren, M ;
Fujii, M ;
Hatabu, H ;
Sugimura, K .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2003, 17 (03) :330-336
[16]   Comparison of contrast-enhanced magnetic resonance angiography and conventional pulmonary angiography for the diagnosis of pulmonary embolism: a prospective study [J].
Oudkerk, M ;
van Beek, EJR ;
Wielopolski, P ;
van Ooijen, PMA ;
Brouwers-Kuyper, EMJ ;
Bongaerts, AHH ;
Berghout, A .
LANCET, 2002, 359 (9318) :1643-1647
[17]  
Schoenberg SO, 1999, JMRI-J MAGN RESON IM, V10, P339, DOI 10.1002/(SICI)1522-2586(199909)10:3<339::AID-JMRI16>3.3.CO
[18]  
2-#
[19]   PHARMACOKINETICS, DOSE PROPORTIONALITY, AND TOLERABILITY OF GADOBUTROL AFTER SINGLE INTRAVENOUS-INJECTION IN HEALTHY-VOLUNTEERS [J].
STAKS, T ;
SCHUHMANNGIAMPIERI, G ;
FRENZEL, T ;
WEINMANN, HJ ;
LANGE, L ;
PLATZEK, J .
INVESTIGATIVE RADIOLOGY, 1994, 29 (07) :709-715
[20]   Value of 1.0-m gadolinium chelates: review of preclinical and clinical data on gadobutrol [J].
Tombach, B ;
Heindel, W .
EUROPEAN RADIOLOGY, 2002, 12 (06) :1550-1556