Equating spatial summation in visual field testing reveals greater loss in optic nerve disease

被引:23
|
作者
Kalloniatis, Michael [1 ,2 ]
Khuu, Sieu K. [2 ]
机构
[1] Univ New South Wales, Ctr Eye Hlth, Kensington, NSW, Australia
[2] Univ New South Wales, Sch Optometry & Vis Sci, Kensington, NSW, Australia
基金
英国医学研究理事会; 澳大利亚研究理事会; 澳大利亚国家健康与医学研究理事会;
关键词
automated perimetry; glaucoma; humphrey field analyzer; octopus visual field; optic nerve head drusen; Ricco's law; spatial summation; STANDARD AUTOMATED PERIMETRY; GLAUCOMA PATIENTS; FULL THRESHOLD; TEST OBJECT; VARIABILITY; AREA; SENSITIVITY; LUMINANCE; DEFECTS; MAGNIFICATION;
D O I
10.1111/opo.12295
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To test the hypothesis that visual field assessment in ocular disease measured with target stimuli within or close to complete spatial summation results in larger threshold elevation compared to when measured with the standard Goldmann III target size. The hypothesis predicts a greater loss will be identified in ocular disease. Additionally, we sought to develop a theoretical framework that would allow comparisons of thresholds with disease progression when using different Goldmann targets. Methods: The Humphrey Field Analyser (HFA) 30-2 grid was used in 13 patients with early/established optic nerve disease using the current Goldmann III target size or a combination of the three smallest stimuli (target size I, II and III). We used data from control subjects at each of the visual field locations for the different target sizes to establish the number of failed points (events) for the patients with optic nerve disease, as well as global indices for mean deviation (MD) and pattern standard deviation (PSD). Results: The 30-2 visual field testing using alternate target size stimuli showed that all 13 patients displayed more defects (events) compared to the standard Goldmann III target size. The median increase for events was seven additional failed points: (range 1-26). The global indices also increased when the new testing approach was used (MD -3.47 to -6.25 dB and PSD 4.32 to 6.63 dB). Spatial summation mapping showed an increase in critical area (Ac) in disease and overall increase in thresholds when smaller target stimuli were used. Conclusions: When compared to the current Goldmann III paradigm, the use of alternate sized targets within the 30-2 testing protocol revealed a greater loss in patients with optic nerve disease for both event analysis and global indices (MD and PSD). We therefore provide evidence in a clinical setting that target size is important in visual field testing.
引用
收藏
页码:439 / 452
页数:14
相关论文
共 50 条
  • [1] Spatial summation across the central visual field: Implications for visual field testing
    Khuu, Sieu K.
    Kalloniatis, Michael
    JOURNAL OF VISION, 2015, 15 (01): : 1 - 15
  • [2] A comparison of Goldmann III, V and spatially equated test stimuli in visual field testing: the importance of complete and partial spatial summation
    Phu, Jack
    Khuu, Sieu K.
    Zangerl, Barbara
    Kalloniatis, Michael
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2017, 37 (02) : 160 - 176
  • [3] Standard Automated Perimetry: Determining Spatial Summation and Its Effect on Contrast Sensitivity Across the Visual Field
    Khuu, Sieu K.
    Kalloniatis, Michael
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (06) : 3565 - 3576
  • [4] Improving Spatial Resolution and Test Times of Visual Field Testing Using ARREST
    Turpin, Andrew
    Morgan, William H.
    Mckendrick, Allison M.
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2018, 7 (05):
  • [5] Archetypal Analysis Reveals Quantifiable Patterns of Visual Field Loss in Optic Neuritis
    Solli, Elena
    Doshi, Hiten
    Elze, Tobias
    Pasquale, Louis
    Wall, Michael
    Kupersmith, Mark
    TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2022, 11 (01):
  • [6] Optic nerve head drusen and visual field loss in normotensive and hypertensive eyes
    Grippo, Tomas M.
    Shihadeh, Wisam A.
    Schargus, Marc
    Gramer, Eugen
    Tello, Celso
    Liebmann, Jeffrey M.
    Ritch, Robert
    JOURNAL OF GLAUCOMA, 2008, 17 (02) : 100 - 104
  • [7] Relationship between optic nerve head microcirculation and visual field loss in glaucoma
    Yaoeda, K
    Shirakashi, M
    Fukushima, A
    Funaki, S
    Funaki, H
    Abe, H
    Tanabe, N
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 2003, 81 (03): : 253 - 259
  • [8] Acquired pits of the optic nerve in glaucoma: Prevalence and associated visual field loss
    Nduaguba, C
    Ugurlu, S
    Caprioli, J
    ACTA OPHTHALMOLOGICA SCANDINAVICA, 1998, 76 (03): : 273 - 277
  • [9] Mapping the Central 10° Visual Field to the Optic Nerve Head Using the Structure-Function Relationship
    Fujino, Yuri
    Murata, Hiroshi
    Matsuura, Masato
    Yanagisawa, Mieko
    Shoji, Nobuyuki
    Inoue, Kenji
    Yamagami, Junkichi
    Asaoka, Ryo
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (07) : 2801 - 2807
  • [10] Advanced visual field loss secondary to optic nerve head drusen: Case report and literature review
    Morris, Robert W.
    Ellerbrock, Joy M.
    Hamp, Ania M.
    Joy, Jeffrey T.
    Roels, Philip
    Davis, Charles N., Jr.
    OPTOMETRY-JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 2009, 80 (02) : 83 - 100