Magnetic Solid-Phase Extraction Combined with Dispersive Liquid-Liquid Microextraction Followed by HPLC for Determination of Four Aromatic Amines Released from Azo Dyes in Paper Samples

被引:2
|
作者
Li, Xiaolan [1 ]
Meng, Dongling [1 ]
Liu, Ruiqi [2 ]
Yang, Yaling [2 ]
机构
[1] China Tobacco Guangxi Ind Co Ltd, Technol Ctr, Nanning 530000, Peoples R China
[2] Kunming Univ Sci & Technol, Fac Life Sci & Technol, Kunming 650093, Yunnan, Peoples R China
关键词
aromatic amines; magnetic solid-phase extraction; dispersive liquid-liquid microextraction; paper samples; WATER SAMPLES; CAPILLARY-ELECTROPHORESIS; OUTDOOR AIR; OLEIC-ACID; NANOPARTICLES; CHROMATOGRAPHY; INDOOR; GC;
D O I
10.21577/0103-5053.20170198
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel extraction technique combining dispersive liquid-liquid microextraction (DLLME) with magnetic solid-phase extraction (MSPE) is presented for pre-concentration of four primary aromatic amines (PAAs) released from azo dyes in paper samples prior to high performance liquid chromatography (HPLC). n-Octanol was used as the extractant and hydrophobic oleic acid modified Fe3O4 nanoparticles (Fe3O4@OA NPs) as an efficient adsorbent was applied to retrieve the PAAs-containing n-octanol in the DLLME step. Because of the rapid mass transfer associated with the DLLME and MSPE steps, fast extraction could be achieved. The main parameters affecting the efficiency of MSPE-DLLME procedure of PAAs were investigated and optimized. Under optimum conditions, the recoveries ranged from 79.6 to 88.5% and the limits of detection (LODs) were in the range of 0.21-1.16 ng mL(-1) (S / N = 3). The intra-day precision (relative standard deviation (RSD)) was below 7.8% and inter-day RSD was less than 11%.
引用
收藏
页码:757 / 765
页数:9
相关论文
共 50 条
  • [1] Determination of four aromatic amines in water samples using dispersive liquid-liquid microextraction combined with HPLC
    Wang, Xuedong
    Fu, Lingyan
    Wei, Guohui
    Hu, Jia
    Zha, Xinna
    Liu, Xiujuan
    Li, Yanyan
    JOURNAL OF SEPARATION SCIENCE, 2008, 31 (16-17) : 2932 - 2938
  • [2] Magnetic solid-phase extraction or dispersive liquid-liquid microextraction for pyrethroid determination in environmental samples
    Pastor-Belda, Marta
    Navarro-Jimenez, Tania
    Garrido, Isabel
    Vinas, Pilar
    Campillo, Natalia
    Fenoll, Jose
    Hernandez-Cordoba, Manuel
    JOURNAL OF SEPARATION SCIENCE, 2018, 41 (12) : 2565 - 2575
  • [3] Molecularly imprinted solid-phase extraction combined with ultrasound-assisted dispersive liquid-liquid microextraction for the determination of four Sudan dyes in sausage samples
    Yan, Hongyuan
    Qiao, Jindong
    Wang, Hui
    Yang, Gengliang
    Row, Kyung Ho
    ANALYST, 2011, 136 (12) : 2629 - 2634
  • [4] Ionic liquid-based dispersive liquid-liquid microextraction followed by magnetic solid-phase extraction for determination of quinolones
    Hong, Jiawei
    Liu, Xiaomei
    Yang, Xiuying
    Wang, Yousheng
    Zhao, Longshan
    MICROCHIMICA ACTA, 2022, 189 (01)
  • [5] Solid-phase extraction combined with dispersive liquid-liquid microextraction for the determination of pyrethroid pesticides in wheat and maize samples
    Zhu, Xiaodan
    Jia, Chunhong
    Zheng, Zuntao
    Feng, Xiaoyuan
    He, Yue
    Zhao, Ercheng
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (23) : 4621 - 4628
  • [6] SOLID-PHASE EXTRACTION FOLLOWED BY DISPERSIVE LIQUID-LIQUID MICROEXTRACTION FOR THE SENSITIVE DETERMINATION OF ECSTASY COMPOUNDS AND AMPHETAMINES IN BIOLOGICAL SAMPLES
    Mashayekhi, Hossein Ali
    Rezaee, Mohammad
    Khalilian, Faezeh
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2014, 28 (03) : 339 - 348
  • [7] Solid-phase extraction followed by dispersive liquid-liquid microextraction for the sensitive determination of selected fungicides in wine
    Montes, R.
    Rodriguez, I.
    Ramil, M.
    Rubi, E.
    Cela, R.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (29) : 5459 - 5466
  • [8] Dispersive Liquid-Liquid Microextraction Coupled with Dispersive μ-Solid-Phase Extraction for the Fast Determination of Polycyclic Aromatic Hydrocarbons in Environmental Water Samples
    Shi, Zhi-Guo
    Lee, Hian Kee
    ANALYTICAL CHEMISTRY, 2010, 82 (04) : 1540 - 1545
  • [9] Determination of Bisphenol A in Food and Environmental Samples Using Combined Solid-Phase Extraction-Dispersive Liquid-Liquid Microextraction with Solidification of Floating Organic Drop Followed by HPLC
    Sadeghi, Marzieh
    Nematifar, Ziba
    Fattahi, Nazir
    Pirsaheb, Meghdad
    Shamsipur, Mojtaba
    FOOD ANALYTICAL METHODS, 2016, 9 (06) : 1814 - 1824
  • [10] Dispersive Liquid-Liquid Microextraction Followed by Magnetic Solid-Phase Extraction for Determination of Four Parabens in Beverage Samples by Ultra-performance Liquid Chromatography Tandem Mass Spectrometry
    Yin, Qinhong
    Zhu, Yanqin
    Yang, Yaling
    FOOD ANALYTICAL METHODS, 2018, 11 (03) : 797 - 807